Medical device recalls
38684 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2023-09-06FDA-DeviceCardiac Assist, IncClass IILifeSPARC Pump (part number 5800-0000) contained within TandemLife LifeSPARC Priming Tray part number: 5800-1000. Note: The 5800-1000 model number is an individually packaged component contained within the Kit numbers: 5830-2916 LS TANDEMLIFE KIT DL29 5840-2417 LS TANDEMLIFE KIT - V24, A17
Epoxy used during manufacturing of the LifeSPARC Pump may have uncured epoxy. if undetectable curing may result in added risk of early pump failure,
- 2023-09-06FDA-DeviceRAYSEARCH LABORATORIES ABClass IIRayCare software, include version number 5A, 5B, 6A, including service packs-An oncology information system used to support workflows and scheduling, as well as clinical information, planning and treatment management for oncology care. Model Numbers: 5.0.0, 5.0.1, 5.1.1,5.1.2, 5.1.3, 6.0.0
An issue was found in Software RayCare 5A, 5B, 6A, including service packs, where an allergy warning against medication substance (drug ingredient) will not be displayed as expected under certain circumstances
- 2023-09-06FDA-DeviceStryker CorporationClass IISurgiCount+ Software Application-indicated as an adjunctive technology for augmenting the manual process of counting, displaying and recording the number of RFID-tagged absorbent articles used during surgical procedures Product Code: 0694-002-090;
Potential for current software to miscount when scanning in multiple sponge-products from the same unique sponge-pack type
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Rescue Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85
Users were identifying autofill failure conditions on the devices causing pump stops.
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Hybrid Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-31, 0998-UC-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-UC-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-UC-0800-52, 0998-00-0800-53, 0998-UC-0800-53, 0998-00-0800-55, 0998-UC-0800-55, 0998-00-0800-65
Users were identifying autofill failure conditions on the devices causing pump stops.
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Rescue Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85
Users were reporting instances of "Gas Loss in IAB Circuit" and "Gas Gain in IAB Circuit" alarms while providing therapy. An internal investigation of the complaints determined that there is a potential trigger for these alarms that was not listed in the IFU: Patient Movement (coughing, general movement, and swallowing). Blood in the circuit, kinks/abrasions of the tubing/catheter and certain patient conditions could also trigger these alarms. The firm's HHE also identified hardware issues related to these alarms.
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Hybrid Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-31, 0998-UC-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-UC-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-UC-0800-52, 0998-00-0800-53, 0998-UC-0800-53, 0998-00-0800-55, 0998-UC-0800-55, 0998-00-0800-65
Users were reporting instances of "Gas Loss in IAB Circuit" and "Gas Gain in IAB Circuit" alarms while providing therapy. An internal investigation of the complaints determined that there is a potential trigger for these alarms that was not listed in the IFU: Patient Movement (coughing, general movement, and swallowing). Blood in the circuit, kins and abrasions of the tubing/catheter and certain patient conditions could also trigger these alarms. The HHE also identified hardware issues related to these alarms.
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Rescue Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85, 0998-UC-0800-75, 0998-UC-0800-83, 0998-UC-0800-85,
Users reported "System Over Temperature" alarms associated with a loss of pumping and/or the Cardiosave system entering Standby mode.
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Hybrid Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-31, 0998-UC-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-UC-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-UC-0800-52, 0998-00-0800-53, 0998-UC-0800-53, 0998-00-0800-55, 0998-UC-0800-55, 0998-00-0800-65, 0998-00-0800-36, 0998-UC-0800-32, 0998-UC-0800-34, 0998-UC-0800-35, 0998-UC-0800-36, 0998-UC-0800-45, 0998-UC-0800-65,
Users reported "System Over Temperature" alarms associated with a loss of pumping and/or the Cardiosave system entering Standby mode.
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Rescue Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85
Users were reporting that the device was not charging as expected. It was discovered that users were unaware that the Cardiosave console was not completely inserted into the hospital cart. If the console is not fully inserted back into the cart the battery(ies) will not charge.
- 2023-09-06FDA-DeviceDatascope Corp.Class ICardiosave Hybrid Intra-Aortic Balloon Pumps (IABP), Part Numbers 0998-00-0800-31, 0998-UC-0800-31, 0998-00-0800-32, 0998-00-0800-33, 0998-UC-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-UC-0800-52, 0998-00-0800-53, 0998-UC-0800-53, 0998-00-0800-55, 0998-UC-0800-55, 0998-00-0800-65
Users were reporting that the device was not charging as expected. It was discovered that users were unaware that the Cardiosave console was not completely inserted into the hospital cart. If the console is not fully inserted back into the cart the battery(ies) will not charge.
- 2023-09-06FDA-DeviceSiemens Healthcare Diagnostics, Inc.Class IIAtellica CH Triglycerides_2: in vitro diagnostic use in the quantitative determination of triglycerides in human serum and plasma (lithium heparin, sodium heparin, potassium EDTA) using the Atellica CH Analyzer. SMN: 11537222
Reagent Carryover from LDL Cholesterol Direct (DLDL), Total Protein II (TP), Triglycerides (Trig), and Triglycerides_2 (Trig_2) Impacting Magnesium (Mg) Results
- 2023-09-06FDA-DeviceSiemens Healthcare Diagnostics, Inc.Class IIAtellica CH Triglycerides (concentrated)-In vitro diagnostic use in the quantitative measurement of triglycerides in human serum and plasma (lithium heparin, potassium EDTA) using the Atellica CH Analyzer SMN: 11097591
Reagent Carryover from LDL Cholesterol Direct (DLDL), Total Protein II (TP), Triglycerides (Trig), and Triglycerides_2 (Trig_2) Impacting Magnesium (Mg) Results
- 2023-09-06FDA-DeviceSiemens Healthcare Diagnostics, Inc.Class IIAtellica CH Total Protein II- In vitro diagnostic use in the quantitative determination of total protein in human serum and plasma (lithium heparin) using the Atellica CH Analyzer. SMN: 11097604
Reagent Carryover from LDL Cholesterol Direct (DLDL), Total Protein II (TP), Triglycerides (Trig), and Triglycerides_2 (Trig_2) Impacting Magnesium (Mg) Results
- 2023-09-06FDA-DeviceSiemens Healthcare Diagnostics, Inc.Class IIAtellica CH LDL Cholesterol Direct (DLDL)-In vitro diagnostic quantitative determination of LDL cholesterol in human serum and plasma (lithium heparin) using the Atellica CH Analyzer. SMN: 11097632
Reagent Carryover from LDL Cholesterol Direct (DLDL), Total Protein II (TP), Triglycerides (Trig), and Triglycerides_2 (Trig_2) Impacting Magnesium (Mg) Results
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX MANTA+, REF numbers: a) B20171743, b) B20171753, c) B20171763, d) B20171773, e) B20171943, f) B20171953, g) B20171963, h) B20171973, i) B20172253, j) B20172263, k) B20172273; intervertebral fusion device - cervical
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX S, REF numbers: a) B15328071S, b) B15328073S, c) B15328074S, d) B15334072S, e) B15334073S, f) B15334074S; intervertebral fusion device - cervical
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX C+, REF numbers: a) B20240104, b) B20240105, c) B20240106, d) B20240107, e) B20240205, f) B20240206, g) B20240207, h) B20240208; intervertebral fusion device - cervical
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIGRANVIA-C, REF numbers: a)¿¿¿¿¿ A13111427, b)¿¿¿¿ A13112567, c)¿¿¿¿¿ A13113456, d)¿¿¿¿ A13131516, e)¿¿¿¿ A13131789, f)¿¿¿¿¿¿ A13132012, g)¿¿¿¿¿ B13111014, h)¿¿¿¿ B13111015, i)¿¿¿¿¿¿ B13111016, j)¿¿¿¿¿¿ B13111017, k)¿¿¿¿¿ B13111025, l)¿¿¿¿¿¿ B13111026, m)¿¿¿ B13111027, n)¿¿¿¿ B13111034, o)¿¿¿¿ B13111035, p)¿¿¿¿ B13111036; intervertebral fusion device - cervical
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIPASS LP, REF numbers: a) B02315535Z, b) B02315540Z, c) B02315545Z, d) B02315550Z, e) B02316535Z, f) B02316540Z, g) B02316545Z, h) B02316550Z, i) B02317540Z, j) B02317545Z, k) B02317550Z; intervertebral fusion device - cervical
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX TLIF, REF numbers: a) B15130607S, b) B15130609S, c) B15130611S, d) B15130613S, e) B15130615S, f) B15900806, g) B15900906, h) B15901006, i) B15901106, j) B15901206, k) B15901306; intervertebral fusion device - lumbar
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX MANTA, REF numbers: a) A20150407, b) A20250407, c) A20350567, d) B20181743, e) B20181753, f) B20181763, g) B20181773, h) B20181943, i) B20181953, j) B20181963, k) B20181973, l) B20182253, m) B20182263; intervertebral fusion device - lumbar
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX DLIF, REF numbers: a) B16123509, b) B16123511, c) B16124009, d) B16124013, e) B16124509, f) B16124511, g) B16124513, h) B16164009, i) B16164013, j) B16165009, k) B16165013; intervertebral fusion device - lumbar
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX ALIF S/A, REF number B15241415; intervertebral fusion device - lumbar
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX ALIF, REF numbers: a) B15111209, b) B15111212, c) B15111409, d) B15111412; intervertebral fusion device - lumbar
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceMedicrea InternationalClass IIIMPIX 3D, REF numbers: a) B242C09122810, b) B242C10062810, c) B242C10122810, d) B242C11062810, e) B242C11122810, f) B242C12062810, g) B242C12122810, h) B242C12123310, i) B242C13062810, j) B242C13122810, k) B242C14122810, l) B242C15122810, m) B247C07062410, n) B247C07062810, o) B247C07063210, p) B247C08062410, q) B247C08062810, r) B247C08063210, s) B247C09062410, t) B247C09062810, u) B247C09063210, v) B247C10062410, w) B247C10062810, x) B247C10063
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
- 2023-08-30FDA-DeviceSiemens Healthcare Diagnostics, Inc.Class IIADVIA Chemistry Urinary/Cerebrospinal Fluid Protein (UCFP), Material Number 11319151, in vitro diagnostic use in the quantitative determination of total protein in human urine and cerebrospinal fluid
There is a potential for ADVIA Chemistry Urinary/Cerebrospinal Fluid Protein reagent carryover impacting Enzymatic Creatinine_2 (ECRE_2). Falsely depressed ECRE_2 results may be observed when the assay is processed after the UCFP test on ADVIA Chemistry systems.
- 2023-08-30FDA-DeviceMedtronic Navigation, Inc.-LittletonClass IIThe O-arm O2 Imaging System is a mobile x-ray system designed for 2D fluoroscopic and 3D imaging for adult and pediatric patients weighing 60 lbs. or greater and having an abdominal thickness greater than 16 cm and is intended to be used where a physician benefits from 2D and 3D information of anatomic structures and objects with high x-ray attenuation such as bony anatomy and metallic objects.
Ground cable installed incorrectly.
- 2023-08-30FDA-DeviceRandox Laboratories Ltd.Class IIRandox Liquid Protein Calibrators-SP CAL-(LIQ)-In vitro diagnostic product used for the calibration of ASO, Complement C3, Complement C4, CRP, Ferritin, Haptoglobin, IgM, Prealbumin, RF and Transferrin assays Catalogue Number: IT2691
As part of the firm's ongoing quality monitoring (see internal complaint # OCC72574), Randox Laboratories have restandardized Ferritin in Liquid Protein Calibrators, IT2691, to reference material NISBC 19/118. The calibrators lots 2112IT-2116IT, packed into batches 627222, 627224, 634886 and 634887 have been reassigned as part of the restandardization. Following this restandardization, Ferritin results for Quality Control material and patient samples recovered erroneously higher than the targeted calibrator values by approximately +10% across the assay range following.
- 2023-08-30FDA-DeviceOlympus Corporation of the AmericasClass IIThe Air/Water Valve is provided/used with the following Endoscopes: ULTRASONIC GASTROFIBERSCOPE, ULTRASONIC GASTROVIDEOSCOPE, ULTRASONIC COLONOVIDEOSCOPE: GF-UC140P-AL5, GF-UCT140-AL5, GF-UE160-AL5, GF-UCT180, GF-UM20, GF-UM130, GF-UMQ130, GF-UM160, GF-UC160P-OL5, GF-UCT160-OL5
The air/water valve MAJ-1444 used with OER-Pro and OER-Elite may become damaged and result in loss of the one-way valve functionality by repeated automated endoscope reprocessing in Olympus OER machines, causing body fluid could backflow into the air/water channel of the ultrasonic endoscopes during the procedure.