Medical device recalls
39137 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2021-03-17FDA-DeviceDraeger Medical, Inc.Class IIVentStar Anesthesia (N) 180 - Drager Breathing Circuits/Anesthesia Sets Order Number: MP00333 - Product Usage: Breathing circuit for conduction of respiratory gases between anesthesia machine or ventilator and patient. Intended for single use only.
Y-piece may become detached from the ventilation hose either before or during the ventilation process, a leak will be caused that can hinder ventilation of the patient.
- 2021-03-17FDA-DeviceCanon Medical System, USA, INC.Class IISystem INFX-8000F
The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.
- 2021-03-17FDA-DeviceCanon Medical System, USA, INC.Class IISystem INFX-8000C
The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.
- 2021-03-17FDA-DeviceCanon Medical System, USA, INC.Class IISystem INFX-8000V
The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.
- 2021-03-10FDA-DeviceSiemens Medical Solutions USA, IncClass IISensis / Sensis Vibe systems with software version VD12 and equipped with HP Flex Pro-C PC. Diagnostic and administrative tool supporting hemodynamic catheterizations and/or electrophysiology studies Model Numbers: Sensis Vibe Hemo 11007641 Sensis Vibe Combo 11007642 Sensis 10764561 Postprocessing Workstation 6648161 SIS Server 6648153
System may sporadically freeze (lock-up) during operation or while being in an idle state, no longer possible to interact with the system
- 2021-03-10FDA-DeviceBarco N.V.Class IIBarco MDNC-3421 DISPLAY, DIAGNOSTIC RADIOLOGY
A number of MDNC-3421 displays were shipped while not being DICOM-compliant. These displays will not pass DICOM acceptance tests.
- 2021-03-10FDA-DeviceBoston Scientific CorporationClass IICaptivator/Captiflex/Sensation Short Throw Single-Use Polypectomy Snares Outer box UPN, Inner pouch UPN: M00560311 (Box 5), M00560310; M00560321 (Box 5), M00560320; M00562651 (Box 5), M00562650; M00562652 (Box 20), M00562650; M00562671 (Box 5), M00562670; M00562672 (Box 20), M00562670; M00562673 (Box 40), M00562670; M00562691 (Box 5); M00562690; M00562692 (Box 20), M00562690; M00562693 (Box 40), M00562690.
Packaging Incomplete Seal. Users noted an incomplete pouch seal prior to using the device in a patient.
- 2021-03-10FDA-DeviceBoston Scientific CorporationClass IICaptivator II Single-Use Polypectomy Snares Outer box UPN, Inner Pouch UPN: M00561191 (Box 10), M00561190; M00561221 (Box 10), M00561220; M00561222 (Box 20), M00561220; M00561223 (Box 40), M00561220; M00561233 (Box 40), M00561230.
Packaging Incomplete Seal. Users noted an incomplete pouch seal prior to using the device in a patient.
- 2021-03-10FDA-DeviceBoston Scientific CorporationClass IICaptivator Single-Use Polypectomy Snares, Captiflex Single-Use Polypectomy Snares. Outer box UPN, Inner Pouch UPN: M00561311 (Box 10), M00561310 M00562301 (Box 10), M00562300; M00562321 (Box 10), M00562320; M00562341 (Box 10), M00562340; M00562451 (Box 10), M00562450; M00562401 (Box 10), M00562400; M00562402 (Box 40), M00562400; M00562422 (Box 40), M00562420; M00562471 (Box 10), M00562470.
Packaging Incomplete Seal. Users noted an incomplete pouch seal prior to using the device in a patient.
- 2021-03-10FDA-DeviceG & H Wire CompanyClass IIBand, Elastic, Orthodontic - Product Usage: Orthodontic elastics, also referred to as rubber bands, are small stretchy loops of rubber that help move teeth into proper alignment during orthodontic treatment. Their purpose is to create additional force for tooth movement in any of the three dimensions that is more difficult using braces alone.
The text on the patient pack is correct and the product itself remains unchanged. FlexMedics does not expect device failures; Instead, there is an opportunity for misuse of the device if the label is not read. If the band is too small, the treatment may be more aggressive. It is important to note that elastic band force decreases over time. If the band is too small and still applied, the band could break. Both circumstances could result in temporary patient discomfort.
- 2021-03-10FDA-DeviceJohnson & Johnson Surgical Vision IncClass IITECNIS Toric 1-Piece IOL, Model Number: ZCT150 +23.5D SE 1.50D CYL - Product Usage: intended to be placed in the capsular bag.
Due to the release of nonconforming Intraocular Lenses (IOLs).
- 2021-03-10FDA-DeviceNihon Kohden America IncClass IIWMTS Telemetry Receiver, Multiple Patient Receiver, Model Number/ UDI: ORG 9100A/ 00841983102554 ORG 9110A/ 00841983102561 ORG 9700A/No UDI
Incorrect Date Stamp or No Data Transfer on Telemetry Receiver and Transmitter.
- 2021-03-10FDA-DeviceAcist Medical SystemsClass IACIST Kodama Intravascular Ultrasound Catheter The Kodama Intravascular Ultrasound Catheter is a component of the ACIST HDi System. The ACIST HDi System is intended to be used for ultrasound examination of coronary and peripheral intravascular pathology. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal interventional procedures. The ACIST Kodama Intravascular Ultrasound Catheter is intended for use with the ACIST HDi System.
Test results from the manufacturing line found a piece of damaged o-ring in an unexpected section of the catheter. Further testing indicated that pieces (>200 micron) of damaged o-ring had the potential to be flushed out of the catheter. ACIST is confirming the source of the failure mode to assure the quality and reliability of the Kodama catheter. There have been no related field reports related to this incident, nor any evidence or report of patient injury or adverse health consequence.
- 2021-03-10FDA-DeviceShanghai United Imaging Healthcare Co., Ltd.Class IIDigitial Medica X-ray Imagining System, Model: uDR 596i, RX, CE0123, UDI:(01) 06971576833023 - Product Usage: intended to used by a qualified/trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen, extremities, limbs and trunk. Not for mammography.
There is a potential for the X-Ray tube head (Touch screen interface) to perform an uncommanded motion. This could result in a collision with the patient.
- 2021-03-10FDA-DeviceReNovo, Inc.Class IIVarious reprocessed products: PROVISION, Reprocessed Smith and Nephew Arthroscopic Shavers, STERILE EO; PROVISION Reprocessed Depy Mitek Ablation Electrodes, VAPR COOLPULSE 90 deg; PROVISION Reprocessed Smith and Nephew Trocars/ Cannulas (Class I); PROVISION Reprocessed Conmed/ Linvatec Suture Retrievers/ Passers C6387 See updated product list attached for details.
Non-sterile product was shipped to customers labelled as sterile.
- 2021-03-10FDA-DeviceBioFire Diagnostics, LLCClass IIBioFire BCID2 Panel; IVD, Rx Only Part No: RFIT-ASY-0147 / UDI: 00815381020338 - Product Usage: intended for use with FilmArray systems.
The firm has identified an increased risk of false positive Pseudomonas aeruginosa when BCID/BCID2 Panels are used with specific BD BACTEC" blood culture vials.
- 2021-03-10FDA-DeviceBioFire Diagnostics, LLCClass IIGram-Negative Bacteria And Associated Resistance Markers; Film Array Blood Culture Identification (BCID); Film Array BCID Panel - Product Usage: intended for use with FilmArray systems. Part No: RFIT-ASY-0126 / UDI: 00815381020086 Part No: RFIT-ASY-0127 / UDI: 00815381020093 IVD, Rx Only
The firm has identified an increased risk of false positive Pseudomonas aeruginosa when BCID/BCID2 Panels are used with specific BD BACTEC" blood culture vials.
- 2021-03-10FDA-DeviceHamilton CoClass IIHAMILTON HEATER SHAKER, 115 VAC/ 230 VAC, 750 VA, Power Consumption 41V/ 100W (max.), Relative Humidity 15% - 85% no condensation. REF 19903400
There is a risk that the device can start a fire if flammable liquids contact and enter the device.
- 2021-03-10FDA-DeviceBovie Medical CorporationClass IIConMed Disposable Bipolar Ablators - Product Usage: intended to be used for cutting, vaporization, and coagulation of soft tissue during arthroscopic surgical procedures.
There can be a potential breach of the sterile packaging barrier due to the development of pinholes at the crease of the double-folded edge of the current package configuration.
- 2021-03-10FDA-DeviceBovie Medical CorporationClass IIHNM Disposable Bipolar Ablators - Product Usage: intended to be used for cutting, vaporization, and coagulation of soft tissue during arthroscopic surgical procedures.
There can be a potential breach of the sterile packaging barrier due to the development of pinholes at the crease of the double-folded edge of the current package configuration.
- 2021-03-10FDA-DeviceBovie Medical CorporationClass IIVelocity Disposable Bipolar Ablators - Product Usage: intended to be used for cutting, vaporization, and coagulation of soft tissue during arthroscopic surgical procedures.
There can be a potential breach of the sterile packaging barrier due to the development of pinholes at the crease of the double-folded edge of the current package configuration.
- 2021-03-10FDA-DeviceCooperSurgical, Inc.Class IIMilex Gellhorn Flexible under the following labels: 1) Gellhorn Flexible w/Short Stem Pessary, REF MXKPGSS2-1/4, 2-1/4" (57 mm) with Kit, 2) Gellhorn Flexible w/Short Stem Pessary, REF MXPGSS2-1/4, 2-1/4" (57 mm) without Kit, 3) Gellhorn Flexible w/Short Stem Pessary, REF MXPGSS2-3/4, 2-3/4" (70 mm)
The affected Milex Gellhorn pessaries were incorrectly manufactured with a long stem (2.170 ), instead of a short stem (1.670 or 1.960 nominal height) as required. The length discrepancy does not meet the released print dimensions.
- 2021-03-10FDA-DeviceBaxter Healthcare CorporationClass IIThe PrisMax System Version II Hemodialysis Delivery System: Automatic Repositioning System Pump Assembly, specifically tubing, Model Numbers: a) 955626 b) 955558 c) 955701 PrisMax V2 Preventive Maintenance Kit, Product Code SC616 ARPS PUMP, Product Code SC6035 ARPS Pump Assembly, Product Code SC6053
Variability in the performance of the tubing in the ARPS (Automatic Repositioning System) Pump Assembly which may lead to alarm situations during system self-test and therapy. This tubing is normally replaced during annual preventative maintenance. Alarm Situations: During System Self-Test: Alarm code B1215 (ARPS Self-Test failure); During Therapy: B1273 (ARPS Leak), B1215 (ARPS Pressure self-test), B1116 (Return Pressure self-test Failure), B1539 (Access Pod Reposition Failure), B1541 (Effluent Pod Reposition Failure), B1540 (Effluent Filter Pod Reposition Failure). If an alarm occurs, it may lead to delay or interruption of therapy. In the event that therapy is terminated without returning blood to the patient, blood loss may occur.
- 2021-03-03FDA-DeviceBaxter Healthcare CorporationClass IIInfusion Pump
Battery performance issues related to prolonged storage.
- 2021-03-03FDA-DeviceSteris CorporationClass IIOT1000 Series Orthopedic Surgical Tables
On January 7, 2021, STERIS identified that the glued bond between the beam and the leg spar assembly may begin to separate over time. This could result in unexpected movement of the affected leg spar if the separation occurred during a patient procedure.
- 2021-03-03FDA-DeviceNorthgate Technologies, Inc.Class IISteris CO2MPACT Endoscopic Insufflator system, Catalog Number 72-00310-0 / 710300 - Product Usage: designed to use CO2 as a distention media in the gastrointestinal tract when used in conjunction with a gastrointestinal endoscope.
An internal tubing component in the flow path was made with incorrect material which was not tested for use with this device.
- 2021-03-03FDA-DeviceNorthgate Technologies, Inc.Class IIConMed 50L abdominal insufflator, Catalog Number 72-00258-0 / GS2000 - Product Usage: The device will maintain an expanded cavity (pneumoperitoneum) to allow the insertion of a variety of surgical instruments through the abdominal wall for visual examination of the interior or for surgery (laparoscopic surgery).
An internal tubing component in the flow path was made with incorrect material which was not tested for use with this device.
- 2021-03-03FDA-DeviceSilk Road Medical IncClass IIENROUTE Transcarotid Stent System REF SR-XXYY-CS
Due to complaints received that the tip/nose cone may detach from the Transcarotid Stent System.
- 2021-03-03FDA-DeviceSmiths Medical ASD Inc.Class IITube Tracheostomy and Tube Cuff, Bivona¿ Cuffless Neonatal/Pediatric FlexTend" Tracheostomy Tube (model 60PFS45, lots 3991171, 3991172, and 3988103) V Neck Flange 4.5mm - Product Usage: intended to provide direct airway access for a tracheotomized patient for up to 29 days. It may be reprocessed for single-patient use up to 5 times.
Smiths Medical became aware that three lot numbers of a specific model of Bivona¿ Cuffless FlexTend" Tracheostomy Tube (model 60PFS45, lots 3991171, 3991172, and 3988103) may have been incorrectly packaged with a straight neck flange instead of a V-neck flange. As a result, there is potential for patient injury if an incorrect device or accessory is selected for use. This use could lead to an internal injury resulting from excessive device contact with tissue, or an external patient injury due to external portions of the device pressing into or rubbing against tissue.
- 2021-03-03FDA-DeviceSiemens Medical Solutions USA, IncClass IIARTIS Icono biplane Model:11327600 ARTIS Icono floor system Model: 11327700 with software version VE20B - Product Usage: Intended for single and biplane diagnostic imaging and interventional procedures.
Misleading error messages and a gap in the Operator Manual which affects ARTIS Icono biplane or ARTIS Icono floor systems with software version VE20B. Potential issues include System error management, Erroneous error messages, Zoom/Pan Function, Grid Indication, and Coolant Level. May cause procedures to be terminated and performed on an alternative x-ray system