Medical device recalls
39229 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2018-01-24FDA-DeviceBoston Scientific CorporationClass IIACCOLADE EL DR Pacemaker
Boston Scientific has received reports of intermittent over-sensing of the Minute Ventilation (MV) sensor signal with certain Boston Scientific pacemaker and cardiac resynchronization therapy pacemaker systems (pacemakers).
- 2018-01-24FDA-DeviceBoston Scientific CorporationClass IIACCOLADE DR Pacemaker
Boston Scientific has received reports of intermittent over-sensing of the Minute Ventilation (MV) sensor signal with certain Boston Scientific pacemaker and cardiac resynchronization therapy pacemaker systems (pacemakers).
- 2018-01-24FDA-DeviceBoston Scientific CorporationClass IIACCOLADE SR Pacemaker
Boston Scientific has received reports of intermittent over-sensing of the Minute Ventilation (MV) sensor signal with certain Boston Scientific pacemaker and cardiac resynchronization therapy pacemaker systems (pacemakers).
- 2018-01-24FDA-DeviceZoll Manufacturing Corp.Class IILifeVest Wearable Defibrillator Model 4000, Product Number 10A0988-A01. The LifeVest system is indicated for patients 18 years of age and older who are at risk for sudden cardiac arrest and are not candidates for or refuse an implantable defibrillator.
Incorrect service code for properly catching critical defects during self-check. Potential for defibrillation shock failure
- 2018-01-24FDA-DeviceMedtronic Sofamor Danek USA IncClass IIMedtronic KYPHON(R) Express(TM) Directional Bone Filler Device, SIZE 2, REF FB, QTY 1 EA, Rx only STERILE R
Medtronic has discovered the directional arrow at the proximal end of the instrument may not correctly align with the cut out opening on the distal end of the instrument.
- 2018-01-24FDA-DeviceHologic, Inc.Class IIAffirm Lateral Arm Upright Biopsy Accessory. Product Number: ASY-09880
The firm is implementing a product correction involving its Affirm¿ Lateral Arm Upright Biopsy Accessory, ASY-09880. The correction has been initiated due to a component (the Left-hand Guide or the Blue Needle Guide) issue that could impact needle alignment for all the left-approach lateral biopsy procedures. This may have an impact on the position of the needle within the breast, and thus on the aspiration of the intended tissue. This impact is case-dependent and detectable when imagining is used to confirm needle position and/or tissue acquisition during and after a procedure. There are no known instances of illness or injury.
- 2018-01-24FDA-DeviceMerge Healthcare, Inc.Class IIFellows "Mighty 8" Power strip (Part Number 04175-0008) and TrippLite Power strip (PS-415-HGULTRA - Part Number 13-00106-00) are two components sold as part of the Merge Hemo System.
Merge is conducting a hardware recall (replacement) of Fellows "Mighty 8" Power Strip and TrippLite Power Strip due to overheat of input resistor causing the power strip to smoke.
- 2018-01-24FDA-DeviceZimmer Biomet, Inc.Class IIPersona Partial Knee System, Size 8, Finishing Guide
Finishing guide does not adequately account for shape differences present in Size 8 of Persona Partial Knee System, potentially resulting in additional surgery time or sensation of tightness during knee flexion.
- 2018-01-24FDA-DevicePhilips Electronics North America CorporationClass IIECG Out Cable - Heartstart MRx M1783A/M5526A 12-pin Sync cables All units of Philips sync cables model M1783A and M5526A as well as Philips ECG out cables model 989803195641. Manufactured - September 4, 2002 October 8, 2014
Issue with ECG out cables. When a Philips monitor/defibrillator is receiving an ECG signal from an auxiliary bedside monitor via a sync cable or ECG out cable, the following can occur if the monitor/defibrillator experiences interference from electrical fast transients (EFTs): " On the HeartStart MRx and HeartStart XL, EFT noise may be misinterpreted as an R-wave. " On the HeartStart XL+, EFT noise can disable ECG monitoring and potentially interrupt demand mode pacing*. *Note: It is contrary to the XL+ Instructions for Use to perform demand mode pacing while using the ECG out cable or obtaining the ECG signal from a bedside monitor. The XL+ Instructions for Use includes the following warning: When pacing in Demand Mode, the ECG cable from the patient must be directly connected to the HeartStart XL+. If the user follows this warning, this problem cannot occur on the XL+.
- 2018-01-24FDA-DeviceStryker NeurovascularClass IITrevo XP ProVue System kit containing 1) Trevo XP ProVue Retriever, 4x20mm and 2) Trevo Pro18 Microcatheter
Stryker Neurovascular has become aware that at least 1 (one) Trevo XP Provue System was manufactured where the carton sleeve did not match the physical contents of the pack.
- 2018-01-24FDA-DeviceSPINEART SAClass IITRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 18 MM, REF TRY-PS-45 18-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (i
Product labeling for TRYPTIK 2-C-PLATE Self Tapping screw, REF TRY-PS 40, Lot 3-5934 contains the sketch/drawing of a self-drilling screw.
- 2018-01-24FDA-DeviceSPINEART SAClass IITRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 16 MM, REF TRY-PS-45 16-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (i
Product labeling for TRYPTIK 2-C-PLATE Self Tapping screw, REF TRY-PS 40, Lot 3-5934 contains the sketch/drawing of a self-drilling screw.
- 2018-01-24FDA-DeviceSPINEART SAClass IITRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 14 MM, REF TRY-PS-45 14-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (i
Product labeling for TRYPTIK 2-C-PLATE Self Tapping screw, REF TRY-PS 40, Lot 3-5934 contains the sketch/drawing of a self-drilling screw.
- 2018-01-24FDA-DeviceSPINEART SAClass IITRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 12 MM, REF TRY-PS-45 12-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (
Product labeling for TRYPTIK 2-C-PLATE Self Tapping screw, REF TRY-PS 40, Lot 3-5934 contains the sketch/drawing of a self-drilling screw.
- 2018-01-24FDA-DeviceSPINEART SAClass IITRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 16 MM, REF TRY-PS-40 16-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (i
Product labeling for TRYPTIK 2-C-PLATE Self Tapping screw, REF TRY-PS 40, Lot 3-5934 contains the sketch/drawing of a self-drilling screw.
- 2018-01-24FDA-DeviceSPINEART SAClass IITRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 14 MM, REF TRY-PS-40 14-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (i
Product labeling for TRYPTIK 2-C-PLATE Self Tapping screw, REF TRY-PS 40, Lot 3-5934 contains the sketch/drawing of a self-drilling screw.
- 2018-01-24FDA-DeviceSPINEART SAClass IITRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 12 MM, REF TRY-PS-40 12-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (i
Product labeling for TRYPTIK 2-C-PLATE Self Tapping screw, REF TRY-PS 40, Lot 3-5934 contains the sketch/drawing of a self-drilling screw.
- 2018-01-24FDA-DeviceHamilton Medical, Inc.Class IIIntellicuff Standalone (PN 951001) Used to continuously measure and automatically maintain the user-set cuff pressure of an endotracheal tube or tracheostomy tube during mechanical ventilation. Used in the ventilation of adults, pediatrics, and neonates.
Issue related to the performance of the motor in recalled product. During use, motor may cease to function.
- 2018-01-24FDA-DeviceDeRoyal Industries IncClass IIDeRoyal Sterile Custom kits containing Covidien-Dover(TM) Irrigation Tray with Piston Syringe Containing Medline Aplicare Povidone Iodine Prep Pads, labeled as follows: (a) Shoulder Arthroscopy Pack 89-8686.01 (b) Shoulder Arthroscopy Pack 89-8686.02 (c) Knee Arthro Pack 89-8687.01 (d) Knee Arthro Pack 89-8687.02 Product Usage: general surgical
DeRoyal manufactured custom sterile surgical kits containing the Covidien-Dover(TM) Irrigation Tray with Piston Syringe that contains the Medline Aplicare Povidone Iodine Prep Pads. The Prep Pads were subsequently recalled because Medline Aplicare determined the product would not support the 36 month expiration date listed on the label.
- 2018-01-17FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIPhilips Healthcare IQon Spectral CT computed tomography x-ray system
There is a possibility that screws holding an internal portion of the gantry (Reaction Ring) to the scanner s main bearing may come loose. If this occurs, the part(s) will not be expelled, however, a noise may be heard coming from the gantry.
- 2018-01-17FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIPhilips Healthcare Brilliance iCT SP computed tomography x-ray system
There is a possibility that screws holding an internal portion of the gantry (Reaction Ring) to the scanner s main bearing may come loose. If this occurs, the part(s) will not be expelled, however, a noise may be heard coming from the gantry.
- 2018-01-17FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIPhilips Healthcare Brilliance iCT computed tomography x-ray system
There is a possibility that screws holding an internal portion of the gantry (Reaction Ring) to the scanner s main bearing may come loose. If this occurs, the part(s) will not be expelled, however, a noise may be heard coming from the gantry.
- 2018-01-17FDA-DevicePhilips Electronics North America CorporationClass IICombiDiagnost R90 Image-Intensified fluoroscopic x-ray system CombiDiagnost R90 is a multi-functional general R/F system. It is suitable for all routine radiography and fluoroscopy exams, including specialist areas like angiography or pediatric work, excluding mammography
The tube adapter-plate green/yellow protective earthing (PE) wire was removed. and spacers with different thickness were used to position pre-loc ring in respect to focal spot in specified distance.
- 2018-01-17FDA-DeviceEncore Medical, LpClass IIEMPOWR Porous Knee System TIBIAL PUNCH, LARGE, REF 801-05-204, NON STERILE, Qty 1 For use in orthopedic surgery.
The Locking Punch Guide was not sufficiently guiding the large press fit punch, causing the implant to be placed 2-3mm more posterior than intended.
- 2018-01-17FDA-DeviceEncore Medical, LpClass IIEMPOWR Porous Knee System TIBIAL PUNCH, MEDIUM, REF 801-05-203, NON STERILE, Qty 1 For use in orthopedic surgery.
The Locking Punch Guide was not sufficiently guiding the large press fit punch, causing the implant to be placed 2-3mm more posterior than intended.
- 2018-01-17FDA-DeviceEncore Medical, LpClass IIEMPOWR Porous Knee System TIBIAL PUNCH, SMALL, REF 801-05-202, NON STERILE, Qty 1 For use in orthopedic surgery.
The Locking Punch Guide was not sufficiently guiding the large press fit punch, causing the implant to be placed 2-3mm more posterior than intended.
- 2018-01-17FDA-DeviceEncore Medical, LpClass IIDJO EMPOWR KNEE LOCKING TIBIAL PUNCH GUIDE, REF 801-05-042, NON STERILE, Qty 1 For use in orthopedic surgery.
The Locking Punch Guide was not sufficiently guiding the large press fit punch, causing the implant to be placed 2-3mm more posterior than intended.
- 2018-01-17FDA-DeviceAmendia, IncClass IIMac Pin Non-Cannulated Screw, 6.5 x 60mm
Incorrect labeling for the lot of MAC Pins. Although the pins are laser as 460 mm in length, the pins are 60 mm in length.
- 2018-01-17FDA-DeviceCordis CorporationClass IICordis S.M.A.R.T. Flex Biliary Stent System Product Usage: Is indicated for use in the palliation of malignant strictures in the biliary tree.
Potential for cracked luer hubs
- 2018-01-17FDA-DeviceCareFusion 303, Inc.Class IIAlaris PCA Pump, Model 8120. The firm name on the label is CareFusion. The Alaris Syringe Pump module and Alaris PCA module are infusion pump modules for the Alaris System. The syringe pump and PCA pump delivers medication or fluids in a manner similar to current syringe pumps on the market. The modules are indicated for use on adults, pediatrics and neonates for continuous or intermittent delivery through clinically acceptable routes of administration such as intravenous, subcutaneous or ep
The syringe plunger grippers may fail to automatically close around the syringe plunger press when the gripper control knob has been closed.