- 2023-11-01FDA-DeviceUniversal Meditech Inc.Class IIHealthyWiser pH-Aware pH 4.5 - 9.0 pH Test Strips REF 900-1P 120 STRIP
Universal Meditech Inc. was violatively distributing PrestiBio" Breastmilk Alcohol Test Strip, DiagnosUS¿ SARS-CoV-2 Antibody (IgG/IgM) Test, HealthyWiser KetoFast" Ketone Test Strips and PrestiBio" Ketone Test Strips without marketing authorization. UMI is also recall their tests because they are going out of business and would not be able to continue fulfilling any post-market responsibilities of these distributed products. UMI claims to hold 510(k)s for the other devices, purchased the intellectual property in 2015 from the previous 510(k) holder, but FDA has been unable to verify this information. The devices may have unknown performance characteristics because the firm is unable to provide any documentation that the devices were manufactured in conformance with the Quality System regulation, including documentation (e.g., DHF) that the distributed devices had not been modified since original clearance in a way that could impact their safety and effectiveness, documentation of controlled storage temperature/humidity, and post-market surveillance documentation, such as complaints and adverse events.
- 2023-11-01FDA-DeviceUniversal Meditech Inc.Class IIHealthyWiser KetoFast" Ketone Test Strips REF 900-1K 150 test strips
Universal Meditech Inc. was violatively distributing PrestiBio" Breastmilk Alcohol Test Strip, DiagnosUS¿ SARS-CoV-2 Antibody (IgG/IgM) Test, HealthyWiser KetoFast" Ketone Test Strips and PrestiBio" Ketone Test Strips without marketing authorization. UMI is also recall their tests because they are going out of business and would not be able to continue fulfilling any post-market responsibilities of these distributed products. UMI claims to hold 510(k)s for the other devices, purchased the intellectual property in 2015 from the previous 510(k) holder, but FDA has been unable to verify this information. The devices may have unknown performance characteristics because the firm is unable to provide any documentation that the devices were manufactured in conformance with the Quality System regulation, including documentation (e.g., DHF) that the distributed devices had not been modified since original clearance in a way that could impact their safety and effectiveness, documentation of controlled storage temperature/humidity, and post-market surveillance documentation, such as complaints and adverse events.
- 2023-11-01FDA-DeviceUniversal Meditech Inc.Class IIHealthyWiser UriTest" UTI Test Strips REF 900-UTI
Universal Meditech Inc. was violatively distributing PrestiBio" Breastmilk Alcohol Test Strip, DiagnosUS¿ SARS-CoV-2 Antibody (IgG/IgM) Test, HealthyWiser KetoFast" Ketone Test Strips and PrestiBio" Ketone Test Strips without marketing authorization. UMI is also recall their tests because they are going out of business and would not be able to continue fulfilling any post-market responsibilities of these distributed products. UMI claims to hold 510(k)s for the other devices, purchased the intellectual property in 2015 from the previous 510(k) holder, but FDA has been unable to verify this information. The devices may have unknown performance characteristics because the firm is unable to provide any documentation that the devices were manufactured in conformance with the Quality System regulation, including documentation (e.g., DHF) that the distributed devices had not been modified since original clearance in a way that could impact their safety and effectiveness, documentation of controlled storage temperature/humidity, and post-market surveillance documentation, such as complaints and adverse events.
- 2023-11-01FDA-DeviceUniversal Meditech Inc.Class IIHealthyWiser UriTest" 10 Parameter Reagent Test Strips for Urinalysis REF 900-10
Universal Meditech Inc. was violatively distributing PrestiBio" Breastmilk Alcohol Test Strip, DiagnosUS¿ SARS-CoV-2 Antibody (IgG/IgM) Test, HealthyWiser KetoFast" Ketone Test Strips and PrestiBio" Ketone Test Strips without marketing authorization. UMI is also recall their tests because they are going out of business and would not be able to continue fulfilling any post-market responsibilities of these distributed products. UMI claims to hold 510(k)s for the other devices, purchased the intellectual property in 2015 from the previous 510(k) holder, but FDA has been unable to verify this information. The devices may have unknown performance characteristics because the firm is unable to provide any documentation that the devices were manufactured in conformance with the Quality System regulation, including documentation (e.g., DHF) that the distributed devices had not been modified since original clearance in a way that could impact their safety and effectiveness, documentation of controlled storage temperature/humidity, and post-market surveillance documentation, such as complaints and adverse events.
- 2023-11-01FDA-DeviceUniversal Meditech Inc.Class IIOne Step Ovulation Test REF 200-01
Universal Meditech Inc. was violatively distributing PrestiBio" Breastmilk Alcohol Test Strip, DiagnosUS¿ SARS-CoV-2 Antibody (IgG/IgM) Test, HealthyWiser KetoFast" Ketone Test Strips and PrestiBio" Ketone Test Strips without marketing authorization. UMI is also recall their tests because they are going out of business and would not be able to continue fulfilling any post-market responsibilities of these distributed products. UMI claims to hold 510(k)s for the other devices, purchased the intellectual property in 2015 from the previous 510(k) holder, but FDA has been unable to verify this information. The devices may have unknown performance characteristics because the firm is unable to provide any documentation that the devices were manufactured in conformance with the Quality System regulation, including documentation (e.g., DHF) that the distributed devices had not been modified since original clearance in a way that could impact their safety and effectiveness, documentation of controlled storage temperature/humidity, and post-market surveillance documentation, such as complaints and adverse events.
- 2023-11-01FDA-DeviceUniversal Meditech Inc.Class IIOne Step Pregnancy Test REF 100-01
Universal Meditech Inc. was violatively distributing PrestiBio" Breastmilk Alcohol Test Strip, DiagnosUS¿ SARS-CoV-2 Antibody (IgG/IgM) Test, HealthyWiser KetoFast" Ketone Test Strips and PrestiBio" Ketone Test Strips without marketing authorization. UMI is also recall their tests because they are going out of business and would not be able to continue fulfilling any post-market responsibilities of these distributed products. UMI claims to hold 510(k)s for the other devices, purchased the intellectual property in 2015 from the previous 510(k) holder, but FDA has been unable to verify this information. The devices may have unknown performance characteristics because the firm is unable to provide any documentation that the devices were manufactured in conformance with the Quality System regulation, including documentation (e.g., DHF) that the distributed devices had not been modified since original clearance in a way that could impact their safety and effectiveness, documentation of controlled storage temperature/humidity, and post-market surveillance documentation, such as complaints and adverse events.
- 2023-10-25FDA-DeviceNorth Coast Medical IncClass IIGladiator, Wrist & Thumb Orthosis, Part Numbers: NC86650 (Small/Left), NC86651 (Small/Right), NC86652 (Medium/Left), NC86653 (Medium/Right), NC86654 (Large/Left), NC86655 (Large/Right), NC86656 (X-Large/Left), and NC86657 (X-Large/Right)
The thumb strap of the wrist and thumb orthosis may contain latex that is not declared in the product labeling.
- 2023-10-25FDA-DeviceOLEA MEDICALClass IIFunctional MR V1.0
When exporting regions of interest in DICOM SEGMENTATION format, when simultaneously exporting multiple volumes of interest, a functional magnetic resonance software bug may cause file contents and associated series descriptions to not match, which could lead to a misinterpretation of clinical data.
- 2023-10-25FDA-DeviceMedtronic NeuromodulationClass IISenSight Connector Plug, Model Number B31061.
Medtronic is requesting return of a small number of units of the SenSight Connector Plug, Model B31061, due to a discrepancy in the Use By Date (UBD) printed on the label.
- 2023-10-25FDA-DeviceMEDLINE INDUSTRIES, LP - NorthfieldClass IIMEDLINE ReNewal Harmonic ACE+7 Shears w/ Adv. Hemostasis Use Only w/ GEN11 SW v2018-1 and Lower, REF HARH45R. surgical instrument.
Various reprocessed Covidien LigaSure and Ethicon Harmonic devices may have an incomplete seal on the packaging tray.
- 2023-10-25FDA-DeviceMEDLINE INDUSTRIES, LP - NorthfieldClass IIMEDLINE ReNewal Ligasure Sealer/Divider Nano-Coated Compatible with FT10 Generator, REF LF4418CR. electrosurgical instrument
Various reprocessed Covidien LigaSure and Ethicon Harmonic devices may have an incomplete seal on the packaging tray.
- 2023-10-25FDA-DeviceMEDLINE INDUSTRIES, LP - NorthfieldClass IIMEDLINE ReNewal Ligasure Maryland Jaw Sealer/Divider Nano-Coated Complatible with FT10 Generator, REF LF1944CR. electrosurgical instrument
Various reprocessed Covidien LigaSure and Ethicon Harmonic devices may have an incomplete seal on the packaging tray.
- 2023-10-25FDA-DeviceMEDLINE INDUSTRIES, LP - NorthfieldClass IIMEDLINE ReNewal Ligasure Blunt Tip Sealer/Divider Nano-Coated Compatible with FT10 Generator, REF LF1844CR. electrosurgical instrument
Various reprocessed Covidien LigaSure and Ethicon Harmonic devices may have an incomplete seal on the packaging tray.
- 2023-10-25FDA-DeviceDeRoyal Industries IncClass IIDeRoyal Head and Neck procedure kit, REF 89-4473, surgical convenience kit
DeRoyal is recalling certain lots of surgical procedure pack products that contain the B.Braun Medical Norm-Ject 2 Piece Syringe. The recall is due to the potential for the sterile packaging barrier to be damaged due to damage to the luer tip of the syringe.
- 2023-10-25FDA-DeviceAccess Vascular, IncClass IIHydroPICC 5Fr Dual Lumen Maximal Barrier Kit, Product Model Number 80002004
Specific lots of the Dual Lumen HydroPICC Kits were provided with the incorrect revision of the Instructions For Use (IFU) which do not include the following warnings statement: HydroPICC Dual Lumen Catheter is for adult use only. There is a potential risk to health should the HydroPICC Dual Lumen Catheter be used in an inadequately sized vessel. There have been no reported adverse events to date.
- 2023-10-25FDA-DeviceAccess Vascular, IncClass IIHydroPICC 5Fr Dual Lumen, 80cm guidewire - Basic Kit, Product Model Number 80002002
Specific lots of the Dual Lumen HydroPICC Kits were provided with the incorrect revision of the Instructions For Use (IFU) which do not include the following warnings statement: HydroPICC Dual Lumen Catheter is for adult use only. There is a potential risk to health should the HydroPICC Dual Lumen Catheter be used in an inadequately sized vessel. There have been no reported adverse events to date.
- 2023-10-25FDA-DeviceTornier, IncClass IIstryker Tornier Perform Reversed Augmented Glenoid Lateralized Baseplate, 25mm, Offset +3mm, REF DWJ502
One lot of Tournier Perform Reversed Lateralized Baseplates were found to have been manufactured with 6mm spacers instead of 3mm spacers. This nonconformance prevents the central screw from being able to thread into the baseplate.
- 2023-10-25FDA-DeviceCardinal Health 200, LLCClass IIMonoject(TM) 1 mL Tuberculin Syringe Luer-Lock Tip Soft Pack, Model Number/Product Code: 1180100777
Syringe contains conical tip that is not compatible with certain needleless IV connector(s).
- 2023-10-25FDA-DeviceEITAN MEDICAL LTDClass ISapphire Infusion Pumps, Models: Multi-Therapy (REF 15031-000-0028), Epidural (REF 15032-000-0027) and SapphirePlus (REF 15038-000-0001)
Infusion Pumps with affected software revision may fail to detect air in line, which may lead to air embolism.
- 2023-10-25FDA-DeviceOlympus Corporation of the AmericasClass IOlympus High-Flow Insufflation Unit, Model UHI-4. For laparoscopic surgery.
There have been reports of patients suffering arrhythmias, reported as short cardiac arrests, during surgical procedures where UHI-4s were used. These events may have been due to an over insufflation of the abdominal cavity resulting from use of the UHI-4 during the procedures.
- 2023-10-18FDA-DeviceBecton Dickinson & Co.Class IIBD BACTEC Plus Aerobic/F Culture Vials, Catalog Number 442023
Certain vials of the BD BACTEC" Plus Aerobic/F Culture Vials have a labeling issue where duplicate barcode sequence numbers have been identified on more than one vial.
- 2023-10-18FDA-DeviceOlympus Corporation of the AmericasClass IITHUNDERBEAT, 5MM, 45CM, Front-actuated Grip Type S Model: TB-0545FCS Indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc) and endoscopic surgery or in any procedure in which cutting, vessel ligation (sealing and cutting), coagulation, gras
Thunderbeats blue seal button may remain in the engaged position after the button is released and not immediately return to a neutral position may result in prolonged surgery
- 2023-10-18FDA-DeviceOlympus Corporation of the AmericasClass IITHUNDERBEAT, 5MM, 35CM, Front-actuated Grip Type S. Model: TB-0535FCS Indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc) and endoscopic surgery or in any procedure in which cutting, vessel ligation (sealing and cutting), coagulation, gra
Thunderbeats blue seal button may remain in the engaged position after the button is released and not immediately return to a neutral position may result in prolonged surgery
- 2023-10-18FDA-DeviceBeckman Coulter, Inc.Class IIDxI 9000 Access Immunoassay Analyzer, REF C11137, Sofware Versions 1.15 and below; invitro diagnostic
The firm has investigated and confirmed that when DxI 9000 is connected to Laboratory Information System (LIS, host), the sample barcode presented may be ignored and replaced with a sample ID that was previously in the same rack and position. This will cause a delay of result to the sample currently presented to the system (Sample B) and may result in an erroneous test result for the prior sample (Sample A), which gets associated with the results of sample B.
- 2023-10-18FDA-DeviceTECHNO-PATH MANUFACTURING LTD.Class IIMultichem P, Part Code 08P90-10
Technopath Manufacturing Ltd. has identified an issue with the glass vial commodity used to fill the Multichem S Plus Level 1, Multichem S Plus Level 2, Multichem S Plus Level 3, Multichem IA Plus and Multichem P Controls. Some customers have experienced broken vials when receiving or thawing Technopath Multichem IA Plus and Multichem S Plus Controls. Breakages have been observed upon delivery, while thawing or while opening the vial. The breakages can result in the bottom of the vial breaking off, breakage in the neck thread area or cracking on the sides of the vial. This may expose the user to biohazardous material if cut and may cause a delay in patient results.
- 2023-10-18FDA-DeviceTECHNO-PATH MANUFACTURING LTD.Class IIMultichem IA Plus, Part Codes: a) 08P86-10, b) 08P86-19
Technopath Manufacturing Ltd. has identified an issue with the glass vial commodity used to fill the Multichem S Plus Level 1, Multichem S Plus Level 2, Multichem S Plus Level 3, Multichem IA Plus and Multichem P Controls. Some customers have experienced broken vials when receiving or thawing Technopath Multichem IA Plus and Multichem S Plus Controls. Breakages have been observed upon delivery, while thawing or while opening the vial. The breakages can result in the bottom of the vial breaking off, breakage in the neck thread area or cracking on the sides of the vial. This may expose the user to biohazardous material if cut and may cause a delay in patient results.
- 2023-10-18FDA-DeviceTECHNO-PATH MANUFACTURING LTD.Class IIMultichem S Plus, Part Codes: a) 08P88-10, b) 08P88-11, c) 08P88-12
Technopath Manufacturing Ltd. has identified an issue with the glass vial commodity used to fill the Multichem S Plus Level 1, Multichem S Plus Level 2, Multichem S Plus Level 3, Multichem IA Plus and Multichem P Controls. Some customers have experienced broken vials when receiving or thawing Technopath Multichem IA Plus and Multichem S Plus Controls. Breakages have been observed upon delivery, while thawing or while opening the vial. The breakages can result in the bottom of the vial breaking off, breakage in the neck thread area or cracking on the sides of the vial. This may expose the user to biohazardous material if cut and may cause a delay in patient results.
- 2023-10-18FDA-DeviceEncore Medical, LPClass IIEMPOWR Acetabular System, Liner, 10¿ Hooded, HXe+, 40H, REF: 942-01-40H
Knee insert and acetabular system parts were swapped within inner pack prior to the product being sealed within the tray, which could result in surgeons not having the correct product for the surgery due to different anatomies (Hip vs Knee).
- 2023-10-18FDA-DeviceEncore Medical, LPClass IIEMPOWR 3D Knee Tibial Insert, 5R, 10MM, VE, REF: 342-10-705
Knee insert and acetabular system parts were swapped within inner pack prior to the product being sealed within the tray, which could result in surgeons not having the correct product for the surgery due to different anatomies (Hip vs Knee).
- 2023-10-18FDA-DeviceMazor Robotics LtdClass IIMAZOR X robotic guidance system, Model TPL0059, with software versions 4.2.2 or 5.0.1