- 2021-08-25FDA-DeviceW L Gore & Associates, Inc.Class IIGore Propaten Vascular Graft configured for Pediatric Shunt, Diameter 6 mm, Length 15 cm, Rx Only, Sterile EO, for the following Reference numbers: HPT060015 UDI: (01)00733132606368 HPT060015A UDI: (01)00733132606375
Vascular Grafts containing an inner diameter of 6 mm may be incorrectly labeled as 5 mm and Vascular Grafts containing an inner diameter of 5 mm are incorrectly labeled as 6 mm.
- 2021-08-25FDA-DeviceW L Gore & Associates, Inc.Class IIGore Propaten Vascular Graft configured for Pediatric Shunt, Diameter 5 mm, Length 10 cm, Rx Only, Sterile EO, for the following Reference numbers: HPT050010 UDI: (01)00733132606320 HPT050010A UDI: (01)00733132606337
Vascular Grafts containing an inner diameter of 6 mm may be incorrectly labeled as 5 mm and Vascular Grafts containing an inner diameter of 5 mm are incorrectly labeled as 6 mm.
- 2021-08-25FDA-DeviceTornier S.A.S.Class IIThe Aequalis Pyrocarbon Humeral Heads. Shoulder implant component. Sold OUS only: a) Catalog # DWH039 - Diameter 39 mm Height 14 mm Eccentric LOW (1.5) Material PyC/CoCr, b) Catalog # DWH041 - Diameter 41 m m Height 15 mm Eccentric LOW (1.5) Material PyC/CoCr, c) Catalog # DWH043 - Diameter 43 mm Height 16 mm Eccentric LOW (1.5) Material PyC/CoCr, d) Catalog # DWH046 - Diameter 46 mm Height 17 mm Eccentric LOW (1.5) Material PyC/CoCr, e) Catalog # DWH048 - Diameter 48 mm Height 18 mm
Potential patient exposure to the graphite substrate.
- 2021-08-25FDA-DevicePhilips Respironics, Inc.Class IITrilogy Evo Universal, Product number DS2000X11B
Two software issues have been identified related to pressure increase in the device: The first issue is described as "Infant/Pediatric EFS Calibration Pressure Increase" and the second issue is described as "Pressure Drift (Continuous Usage).
- 2021-08-25FDA-DevicePhilips Respironics, Inc.Class IITrilogy EV300, Product numbers CA2200X12B, DS2200X11B, FX2200X15B, IN2200X15B
Two software issues have been identified related to pressure increase in the device: The first issue is described as "Infant/Pediatric EFS Calibration Pressure Increase" and the second issue is described as "Pressure Drift (Continuous Usage).
- 2021-08-25FDA-DevicePhilips Respironics, Inc.Class IITrilogy Evo O2, Product numbers DE2100X13B, DS2100X11B, EE2100X15B, ES2100X15B, EU2100X15B, FR2100X14B, FX2100X15B, IA2100X15B, IN2100X15B, IN2100X19, IT2100X21B, JP2100X16B, LA2100X15B, ND2100X15B, RDE2100X13B, SP2100X26B
Two software issues have been identified related to pressure increase in the device: The first issue is described as "Infant/Pediatric EFS Calibration Pressure Increase" and the second issue is described as "Pressure Drift (Continuous Usage).
- 2021-08-25FDA-DevicePhilips Respironics, Inc.Class IITrilogy Evo, Product numbers BL2110X15B, CA2110X12B, DE2110X13B, DS2110X11B, EE2110X15B, ES2110X15B, EU2110X15B, EU2110X19, FR2110X14B, GB2110X15B, IA2110X15B, IN2110X15B, IN2110X19, IT2110X21B, KR2110X15B, LA2110X15B, LD2110X23B, ND2110X15B, RDE2110X13B, UDS2110X11B
Two software issues have been identified related to pressure increase in the device: The first issue is described as "Infant/Pediatric EFS Calibration Pressure Increase" and the second issue is described as "Pressure Drift (Continuous Usage).
- 2021-08-25FDA-DeviceCardinal Health 200, LLCClass IArgyle UVC Insertion Tray containing Safety Scalpel N11 (vendor part number 73-1811). Intended for use to insert an Umbilical Venous Catheter (UVC) into the umbilical artery or vein of neonate. Product Code: 43201
The current Argyle UVC Insertion Tray does not include a specific IFU to operate the Safety Scalpel N11. The Safety Scalpel N11 features a permanent locking feature that will not allow the clinician to unlock the scalpel once the safety shield is closed and pushed forward into a locked position may result in a delay treatment/therapy, which could ultimately result in death.
- 2021-08-18FDA-DeviceEdwards Lifesciences, LLCClass IIEdwards PediaSat Oximetry Catheter Set, REF: XT3515SJ, Exterior Diameter 5.5F, Usable Length 15 cm, Number of Lumens: 3, Rx Only, Sterile EO, UDI: (01)00690103197501 *NOT DISTRIBUTED WITHIN THE US
There is a potential for internal leaks within catheters.
- 2021-08-18FDA-DeviceEdwards Lifesciences, LLCClass IIEdwards PediaSat Oximetry Catheter Set, REF: XT358KTP, Exterior Diameter 5.5F, Usable Length 8 cm, Number of Lumens: 3, Recommended Guidewire Size: GW: 0.025" (0.64 mm), Rx Only, Sterile EO, UDI: (01)00690103197556
There is a potential for internal leaks within catheters.
- 2021-08-18FDA-DeviceEdwards Lifesciences, LLCClass IIEdwards PediaSat Oximetry Catheter Set, REF: XT358SP, Exterior Diameter 5.5F (1.83 mm), Usable Length 9 cm, Number of Lumens: 3, Recommended Guidewire Size: GW: 0.025" (0.64 mm), Rx Only, Sterile EO, UDI: (01)00690103197525 *NOT DISTRIBUTED WITHIN THE US
There is a potential for internal leaks within catheters.
- 2021-08-18FDA-DeviceEdwards Lifesciences, LLCClass IIEdwards PediaSat Oximetry Catheter Kit, REF: XT358SJ, Usable Length 8 cm, Number of Lumens 3, Exterior Diameter 5.5F, Rx Only, Sterile EO, UDI: (01)00690103197495 *NOT DISTRIBUTED WITHIN THE US
There is a potential for internal leaks within catheters.
- 2021-08-18FDA-DeviceEdwards Lifesciences, LLCClass IIEdwards PediaSat Oximetry Catheter Kit, REF: XT3515SP, Exterior Diameter 5.5F (1.83 mm), Usable Length 15 cm, Number of Lumens 3, Recommended Guidewire Size 0.025" (0.64 mm), Rx Only, Sterile EO, UDI: (01)00690103197532
There is a potential for internal leaks within catheters.
- 2021-08-18FDA-DeviceEdwards Lifesciences, LLCClass IIEdwards PediaSat Oximetry Catheter Kit, REF: XT3515KTP, Exterior Diameter 5.5F (1.83 mm), Usable Length 15 cm, Number of Lumens 3, Recommended Guidewire Size 0.025" (0.64 mm), Rx Only, Sterile EO, UDI: (01)00690103197563
There is a potential for internal leaks within catheters.
- 2021-08-18FDA-DeviceQURA S.R.L.Class IISpectrum Medical Quantum Standard heat exchanger
Product labeled as sterile may not have been adequately sterilized. In addition, these devices were imported to the US distributor, but the devices are not 510(k) cleared in the US.
- 2021-08-18FDA-DeviceAbbott Laboratories, IncClass IIAlinity s System REF 06P16-01. An automated immunoassay analyzer for In Vitro diagnostic use in blood donor screening, plasma and plasmapheresis screening, and organ donor centers, hospitals, and reference laboratories.
A design defect (hardware and software) allows liquid waste pressure to build up and potentially spray users/operators.
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size D, 80 MM Item Number: 11-301354
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System Standard Cone Prox Body, Size C, 80 MM Item Number: 11-301343
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System Standard Cone Prox Body, Size B, 80 MM Item Number: 11-301342
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size E, 70 MM Item Number: 11-301335
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size C, 70 MM Item Number: 11-301333
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size A, 70 MM Item Number: 11-301331
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System Standard Cone Prox Body, Size E, 70 MM Item Number:11-301325
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System Standard Cone Prox Body, Size B, 70 MM Item Number: 11-301322
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System Standard Cone Prox Body, Size A, 70 MM Item Number: 11-301321
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size E, 60 MM Item Number: 11-301315
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size D, 60 MM Item Number: 11-301314
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size B, 60 MM Item Number: 11-301312
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size A, 60 MM Item Number: 11-301311
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention
- 2021-08-18FDA-DeviceBiomet, Inc.Class IIArcos Modular Revision Hip System High Offset Cone Prox Body, Size A, 50 MM Item Number: 11-301310
Arcos Proximal Cone Bodies could potentially exhibit chatter in the inner taper fretting corrosion and device failure in vivo leading to surgical intervention