Medical device recalls
39137 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2021-05-05FDA-DeviceSmith & Nephew, Inc.Class IICANNU-Flex SILK Interference Screws 6 mmx 30 mm - Product Usage: used for interference fixation of bone-tendon-bone of soft tissue grafts in anterior cruciate ligament reconstruction, Part Number: 014208
Mislabeled box contained a 6mm x 20mm screw instead of 6mm x 30mm screw
- 2021-05-05FDA-DeviceB. Braun Medical, Inc.Class IIFiltered Triple-Leg Extension Set - Intravascular administration set. Product Catalog number: 477034 - Product Usage: The extension set is a sterile, single-use intravascular direct injection, intermittent infusion, continuous infusion or aspiration of fluids and medications.
BBMI has identified through complaints the potential for the extension set to become occluded or unable to prime.
- 2021-05-05FDA-DeviceCHANGE HEALTHCARE CANADA COMPANYClass IIChange Healthcare Enterprise Viewer
Change Healthcare has identified an intermittent software defect which may result in an anchor study failing to display.
- 2021-05-05FDA-DeviceDatascope Corp.Class IIICardiosave Rescue IABP - Product Usage: used to inflate and deflate intra-aortic balloons. It provides temporary support to the left ventricle via the principle of counterpulsation, Model Numbers 0998-00-0800-75, 0998-00-0800-83, 0998-00-0800-85
There are cybersecurity vulnerabilities in a widely used low-level TCP/IP software library that may result in a loss of communication to the Hospital Information System/Clinical Information System (HIS/CIS).
- 2021-05-05FDA-DeviceDatascope Corp.Class IIICardiosave Hybrid IABP - Product Usage: used to inflate and deflate intra-aortic balloons. It provides temporary support to the left ventricle via the principle of counterpulsation, Model Numbers 0998-00-0800-32, 0998-00-0800-33, 0998-00-0800-34, 0998-00-0800-35, 0998-00-0800-45, 0998-00-0800-52, 0998-00-0800-53, 0998-00-0800-55, 0998-00-0800-65
There are cybersecurity vulnerabilities in a widely used low-level TCP/IP software library that may result in a loss of communication to the Hospital Information System/Clinical Information System (HIS/CIS).
- 2021-05-05FDA-DeviceMerits Holdings Co. dba Merits Health Products, Inc.Class IIScooter
Seat baseplate pin has broken in the field.
- 2021-05-05FDA-DeviceMerits Holdings Co. dba Merits Health Products, Inc.Class IIPower Wheelchair
Seat baseplate pin has broken in the field.
- 2021-05-05FDA-DeviceClark Laboratories, Inc.Class IITrinity Biotech Captia Measles IgM Kit, Catalog No. 2326060 - Product Usage: intended for the qualitative detection of Measles igM antibodies in human serum of patients suspected of measles (rubeola) infection.
Positive Control may run high out of its assigned ISR range and result in an invalid run and necessitate retesting
- 2021-05-05FDA-DeviceMedela AG Medical TechnologyClass IIStryker Medela REF 077.0193 AXS Universal Aspiration Tubing (01)07612367053921 - Product Usage: AXS Universal Aspiration Tubing is used with the Dominant Flex Surgical Suction Pump.
Incorrect expiration date of "2023-07-24" on label of sterile tubing. Correct expiration date should be "2021-07-24".
- 2021-05-05FDA-DeviceNextremity SolutionsClass IIInCore Lapidus Disposable Kit 28mm Right, Part Number: IC-LAP-28R - Product Usage: Intended as a three-part construct intended for internal fixation for First Metatarsocuneiform arthrodesis.
Product could potentially contain an undersized inner diameter of the 40mm drill bushing which result in not allowing the drill bit to pass through the drill bushing, causing inability of surgeon to complete surgical procedure as intended
- 2021-05-05FDA-DeviceNextremity SolutionsClass IIInCore Lapidus Disposable Kit 28mm Left, Part Number: IC-LAP-28L - Product Usage: Intended as a three-part construct intended for internal fixation for First Metatarsocuneiform arthrodesis.
Product could potentially contain an undersized inner diameter of the 40mm drill bushing which result in not allowing the drill bit to pass through the drill bushing, causing inability of surgeon to complete surgical procedure as intended
- 2021-05-05FDA-DeviceConMed CorporationClass IIKIT_INFINITY_BASE Custom Procedural Kit - Italy, containing Infinity ACL Tibial Elbow and Tip Guides product line, KTE100 and KTT100. For use in open and arthroscopic procedures for knee ligament reconstruction The procedural kits have no kit specific labeling. Each product within the kits has its own product specific labeling.
Tip Guides are potentially misaligned laterally which could affect the accuracy of the guide system and could cause a delay in procedure and may require another device or alternate surgical method to be used
- 2021-05-05FDA-DeviceConMed CorporationClass IIINFINITY_TRAY Custom Procedural Kit - Canada. containing Infinity ACL Tibial Elbow and Tip Guides product line, KTE100 and KTT100. For use in open and arthroscopic procedures for knee ligament reconstruction. The procedural kits have no kit specific labeling. Each product within the kits has its own product specific labeling.
Tip Guides are potentially misaligned laterally which could affect the accuracy of the guide system and could cause a delay in procedure and may require another device or alternate surgical method to be used
- 2021-05-05FDA-DeviceSiemens Medical Solutions USA, IncClass IIInterventional Fluoroscopic X-Ray System ARTIS icono biplane- 11327600 ARTIS icono floor- 11327700 ARTIS pheno- 10849000 ARTIS is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients.
Siemens has become aware of a potential issue with software version VE20C. Planned procedures may have to be terminated and performed on an alternative x-ray system.
- 2021-05-05FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis systems - Product Usage: an angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Model Numbers: System Material # AXIOM Artis FC 05904433; AXIOM Artis FA 05904441; AXIOM Artis MP 05904466; AXIOM Artis BC 05904649; AXIOM Artis BA 05904656; AXIOM Artis dBC Mag. Nav. 05917054; AXIOM Artis TA 07007755; AXIOM Artis dTA 07008605; AXIOM Artis dFC 07412807; AXIO
Due to inappropriate cleaning, some Artis systems show unexpected corrosion of visible belts which are needed to move system parts (e.g. C-Arm), Increased corrosion may lead to a malfunction of the belts which may result in limited functionality of the Artis system up to system failure. Unintended movement of the C-Arm may cause a hazardous situation to the patient, operator, or staff members and may result in a situation where it is necessary to cancel clinical treatment or to continue treatment on an alternative system
- 2021-05-05FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis zee ceiling-interventional Fluoroscopic X-Ray System Model Number: 10094137
Some Artis zee ceiling systems show an increased abrasion of the cabling at the cable outlet of the inner C-arm, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where it is necessary to cancel clinical treatment or to continue treatment on an alternative system.
- 2021-05-05FDA-DeviceColtene Whaledent IncClass IIDental pins - TMS LINK PLUS Self-Threading Pins - Product Usage: implanted into the teeth or for lab use for dental restoration purposes. The normal procedure requires a hole to be drilled into the tissue of a tooth with an intraoral drill prior to installation. Model number/Catalog number: L741
The incorrect dental pins were packaged and subsequently distributed.
- 2021-05-05FDA-DeviceCytocell Ltd.Class IIChromosome X Alpha-Satellite in FITC Spectrum - Product Usage: Analyte Specific Reagents. Model: MPA3481
Users may observe additional locus specific signals at 9q34. The device pack insert indicates the probe has no known cross-reactivity to 9q34.
- 2021-05-05FDA-DeviceBoston Scientific CorporationClass IIIEXALT Controller - Product Usage: intended for use with a Boston Scientific endoscope for endoscopic diagnosis, treatment, and video observation. UPN: M00542430
May have been programmed with a less than optimal brightness setting resulting in a darker than desired image
- 2021-05-05FDA-DeviceBoston Scientific CorporationClass IIUpsylonTM Y Mesh Kit with Colpassist Vaginal Positioning Device - Product Usage: intended for use as a bridging material for sacrocolposuspension/sacrocolpopexy (laparotomy, laparoscopic or robotic approach Material No.M0068318220 Individually packaged Upsylon Y Mesh (UPN M0068318200) is not impacted by this removal. Note: The UpsylonTM Y Mesh Kit consists of UpsylonTM Y Mesh and ColpassistTM Vaginal Positioning Device packaged and sterilized separately and then combined into a kit carton.
Potential for pinholes (sterile barrier breach) on the edge of the pouch to potentially render the device non-sterile, and may result in a post-operative infection
- 2021-05-05FDA-DeviceBoston Scientific CorporationClass IIColpassist Vaginal Positioning Device - Product Usage: intended for use in general gynecological surgery to assist in the positioning and manipulation of the vagina during the procedure. Material No. M0068318210
Potential for pinholes (sterile barrier breach) on the edge of the pouch to potentially render the device non-sterile, and may result in a post-operative infection
- 2021-05-05FDA-DeviceOrtho-Clinical Diagnostics, INc.Class IIVITROS¿ Black Reference Slides CATALOG #: J02316 - Product Usage: The Black Reference Slide is a part/ tool used in the reflectometer correction factor adjustment procedure.
Delayed results. Ortho confirmed that two lots of VITROS Black Reference Slides are incorrectly labelled as White Reference Slides. If the customer fails to notice both the product name or the unexpected color of the slides and tries to use Black Reference Slides as White Reference Slides, the Correction Factor test will fail - and the analyzer will not be able to produce results for any assays other than sodium, potassium, and chloride. If the customer doesnt have any White Reference Slides in reserve, they cant run the Correction Factor test correctly and get the analyzer running again until they get more White Reference Slides delivered. This could lead to a delay in results for all Vitros assays except for sodium, potassium, and chloride.
- 2021-05-05FDA-DeviceLuminex CorporationClass IIVERIGENE Processor SP - Product Usage: intended for processing and identifying nucleic acids utilizing gold nanoparticle probe technology.
Potential for a false-negative result for Vibrio parahaemolyticus, Salmonella, and/or Shigella spp when used with the VERIGENE Enteric Pathogens Nucleic Acid Test Kit.
- 2021-05-05FDA-DeviceBaxter Healthcare CorporationClass IISpectrum IQ - Infusion Pump - Product Usage: intended to be used for the controlled administration of fluids.
Potentially defective component in the AC power adapter which may fail over time.
- 2021-05-05FDA-DeviceCardiac Assist, IncClass IIProtek Solo Venous Dilator Set: dilator, vessel, for percutaneous catheterization. Catalog #: 5840-2417 - LS Tandem Life Kit - V24/A17 Catalog #: 5840-2415 - LS Tandem Life Kit - V24/A15 Catalog #: 5740-2417 - TandemLife Kit - V24/A17 Catalog #: 5100-1422 - ProtekSolo Venous Dilator Set (14-22 Fr)
On 02/26/2021, it was found that there were incorrectly packaged Dilator sets in Finished Goods. On 03/1/2021, it was confirmed that 14 kits containing the impacted products had been distributed to the field.
- 2021-04-28FDA-DeviceWelch Allyn Inc MortaraClass IIAM12M Acquisition Module accessory. Impacted software version of the AM12M is version 1.5.1 - Product Usage: indicated for use on adult and pediatric populations.
Devices do not meet IEC 60601-2-27 requirements as labeled.
- 2021-04-28FDA-DeviceWelch Allyn Inc MortaraClass IISurveyor S12/S19 Bedside Patient Monitor, with AM12M Acquisition Module accessory. Impacted software version of the AM12M is version 1.5.1 - Product Usage: indicated for use on adult and pediatric populations.
Devices do not meet IEC 60601-2-27 requirements as labeled.
- 2021-04-28FDA-DeviceWelch Allyn Inc MortaraClass IIELI 380 Electrocardiograph, with AM12M Acquisition Module accessory. Impacted software version of the AM12M is version 1.5.1 - Product Usage: indicated for use on adult and pediatric populations.
Devices do not meet IEC 60601-2-27 requirements as labeled.
- 2021-04-28FDA-DeviceWelch Allyn Inc MortaraClass IIELI 280 Electrocardiograph, with AM12M Acquisition Module accessory. Impacted software version of the AM12M is version 1.5.1 - Product Usage: indicated for use on adult and pediatric populations.
Devices do not meet IEC 60601-2-27 requirements as labeled.
- 2021-04-28FDA-DeviceSmiths Medical ASD Inc.Class IIMedex 10 IN Pressure Injector Line w/Rot (1200psi) NS. REF B1681R, component of extravascular blood-pressure Transducer.
Specific lots of Medex High Pressure Adaptors, Rotators, Manifolds, Stopcocks and Tubing and Medex LogiCal Kits may have been manufactured with insufficient or incomplete welds. These are components for various cardiac kits including pressure monitoring devices and interventional imaging devices.