- 2020-04-08FDA-DeviceGentell, IncClass IIGentell Hydrogel Ag 2x2, model no GEN-11220 - Product Usage: Under the care of a healthcare professional, Gentell Hydrogel Ag Saturated Gauze is indicated for partial and full thickness wounds, including pressure ulcers, venous stasis ulcers, diabetic ulcers, first and second degree burns and skin tears. It provides a moist wound environment for healing.
During an FDA audit, it was discovered that the product was not properly registered with FDA.
- 2020-04-08FDA-DeviceRespironics California, LLCClass IIPhilips V60 Ventilators with Power Management PCBA part number 1055906
Solder connection failure on Power Management printed circuit board assembly of ventilators may cause 1) Blower to lose power, spool down, and trigger visual and audible High Priority Check Vent alarm indicating a need for alternative ventilation, or 2) Intermittent connection may disrupt expected operation and trigger unexpected shutdown without alarm. Failures may lead to hypercarbia/hypoxemia
- 2020-04-08FDA-DeviceStryker NeurovascularClass IIStryker Neurovascular, AXS Vecta 74 Aspiration Catheter, Ref. Catalog No. INC-11597-115, Use By 2021-11-29, Rx Only, Sterile/EO, Manufactured For: Stryker Neurovascular 47900 Bayside Parkway, Fremont, CA 94538, UDI: (01)07613327459241(17)211129(10)00000-00 Stryker Neurovascular, AXS Vecta 74 Aspiration Catheter, Ref. Catalog No. INC-11597-125, Use By 2021-11-29, Rx Only, Sterile/EO, Manufactured For: Stryker Neurovascular 47900 Bayside Parkway, Fremont, CA 94538, UDI: (01)07613327459258(17)21
The firm has become aware of a potential problem that their Catheters may break/fracture and/or kink/bend if improperly removed from the packaging/dispenser hoop or during catheter use.
- 2020-04-08FDA-DeviceStryker NeurovascularClass IIStryker Neurovascular, AXS Vecta 71 Aspiration Catheter, Ref. Catalog No. INC-11129-115, Use By 2021-11-29, Rx Only, Sterile/EO, Manufactured For: Stryker Neurovascular 47900 Bayside Parkway, Fremont, CA 94538, UDI: (01)07613327459210(17)211129(10)00000-00 Stryker Neurovascular, AXS Vecta 71 Aspiration Catheter, Ref. Catalog No. INC-11129-125, Use By 2021-11-29, Rx Only, Sterile/EO, Manufactured For: Stryker Neurovascular 47900 Bayside Parkway, Fremont, CA 94538, UDI: (01)07613327459227(17)21
The firm has become aware of a potential problem that their Catheters may break/fracture and/or kink/bend if improperly removed from the packaging/dispenser hoop or during catheter use.
- 2020-04-08FDA-DeviceThe Binding Site Group, Ltd.Class IIC-Reactive Protein Kit for use on the SPAplus, REF NK044.S.A, Rx only, UDI (01)05051700018456,
A reagent in C reactive protein kits is not performing to specification and samples with known concentrations less-than-or-equal to 10 mg/L may be affected
- 2020-04-08FDA-DeviceKarl Storz EndoscopyClass IIKarl Storz SE & Co. KG, C-MAC Video Laryngoscope MIL # 1, for the following REF numbers: 1. 8403xx series, which includes: 8403AX, AXC, BX, BXC, DXC, EXC, GXC, HX, HXK, HXP, KXC, MXC 2. 8401xx series, which includes: 8401AX, AXC, BX, BXC, DXC, GXC, HX, HXP, KXC. Product Usage: Video Laryngoscopes are used to visualize the airways and vocal cords during endotracheal intubation and for the inspection and examination of the upper respiratory tract. Video Laryngoscopes are designed for tr
The firm has become aware that there is a potential that the glass cover at the distal end of the camera/led lighting on the video laryngoscope could become loose during reprocessing or use. If this occurs during usage, it may result in a delay in procedure and/or require removal from body.
- 2020-04-08FDA-DeviceHaemonetics CorporationClass IITEG Manager software versions used in conjunction with TEG 5000 are 1.1.0, 3.0.0, 4.0.0, 4.1.0 and 4.1.1. Intended: For in vitro coagulation studies
Software defect in TEG Manager impacts the displayed alert for out of range test results. Due to this defect, reference range values received from TEG 5000 and displayed on the TEG Manager test result screen are rounded to the nearest whole number and lead to TEG Manager displaying an out of range alert when the test result is actually in range, or vice versa.
- 2020-04-08FDA-DevicePhilips North America, LLCClass IIExpression MR400 MRI Patient Monitoring System Model Number: 866185 Software version number: 01.03.00, 01.04.00, 01.05.00, and 01.07.00 - Product Usage: The Expression Model MR400 MRI Patient Monitoring Systems is intended for use by healthcare professionals to monitor vital signs of patients undergoing MRI procedures and to provide signals for the synchronization of the MRI scanner.
Menu selections for users to access the oxygen (O2) sensor calibration were changed and not incorporated into the device s Instructions for Use. As a result, the instructions for performing the O2 sensor calibration are incorrect for customers performing this task with an MR400 device with software revisions: 01 .03.00, 01.04.00, 01 .05.00 and 01 .07.00
- 2020-04-08FDA-DeviceBiomet, Inc.Class IIBiomet Comprehensive Reverse Shoulder Glenosphere Mini Baseplate With Taper Adapter-indicated for primary, fracture, or revision total shoulder replacement for the relief of pain and significant disability due to gross rotator cuff deficiency Item Number: 010000589
Package is intended to contain one (1) baseplate and one (1) taper adapter; however, devices may be packaged with two (2) baseplates and no (0) adapters.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd Small Joint Reaming System, Model 311-00-001. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd Gridlock Ankle Plating System, Model 320-01-100. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for: (1) Trilliant Surgical Ltd Tiger Large Cannulated Screw System, Model 215-00-001; and (2) Trilliant Surgical Ltd Large Cannulated Headless Screw System, Model 215-00-001. The firm name on the label is Trilliant Surgical Ltd., Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd 3S Hemi Toe Implant System, Model 111-00-001. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd Two-Step Hammertoe Implant System, Model 214-00-001. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd Gridlock Plating System, Model 310-01-100. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd Disco Subtalar Implant System, Model 112-00-001. The firm name on the label is Trilliant Surgical, Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning Sterilization Protocol for Trilliant Surgical Ltd Twist Sublatar Implant System, Model 112-00-001. The firm name on the label is Trilliant Surgical, Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for: (1) Trilliant Surgical Ltd Tiger Headless Cannulated Screw System, Model 212-00-001; and (2) Combination Tiger Cannulated/Tiger Headless Cannulated Screw System, Model 210-00-101. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceTrilliant Surgical, LLCClass IIInstructions for Use and Surgical Cleaning and Sterilization Protocol for: (1) Trilliant Surgical Tiger Cannulated Screw System, Model 210-00-001; and (2) Combination Tiger/Tiger Headless Cannulated Screw System, Model 210-00-101. The firm name on the label is Trilliant Surgical, Houston, TX.
Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.
- 2020-04-08FDA-DeviceDeRoyal Industries IncClass IIDeRoyal SECURITY CUFFS, Single Strap, QR Buckle Cuff and Bed, UNIVERSAL, REF M8138 - Product Usage: patient restraint.
One lot of product was inadvertently manufactured with a buckle which does not meet the mechanical hold force required for this device.
- 2020-04-08FDA-DeviceMaquet Cardiovascular Us Sales, LlcClass IIAvalon Elite Vascular Access Kit, Model No. 70106.3540, UDI 04037691831039
A lot of Avalon Elite Vascular Access Kits (VAK) are being recalled due to a material mix-up with the needle portion of the kit; 81 of 255 kits were assembled with an incorrect Arterial Access Needle instead of a Multi-Purpose Procedure Needle.
- 2020-04-08FDA-DeviceStryker CommunicationsClass IIBerchtold Chromophare Ceiling Mounted Surgical Light System, Catalog #CH13000000
The firm has become aware that there is a likelihood that a missing snap ring or spanner nut may result in an insufficient mount force that causes the surgical light to fall. If the suspension of the surgical light falls, it may potentially cause serious injuries to Health Care Providers and/or patients.
- 2020-04-08FDA-DeviceButterfly Network, Inc.Class IIButterfly iQ Ultrasound System containing the Auto EF(Ejection Fraction) Tool REF/Model: 850-20003 UDI: (01)00866646000206 Software versions 1.10.0, 1.11.0, 1.12.0, 1.13.0, 1.13.0, 1.14.0, 1.15.0 Product Usage: Intended use: Diagnostic ultrasound imaging and measurement of anatomical structures.
Distributed without an approved 510(k)
- 2020-04-08FDA-DeviceButterfly Network, Inc.Class IIButterfly iQ Ultrasound System Auto Bladder Volume Tool-The Auto Bladder Volume Tool is a segmentation measurement tool REF/Model: 850-20003 Software versions 1.13.0, 1.14.0, and 1.15.0 - Product Usage: Butterfly iQ is indicated for use by qualified and trained healthcare professionals to enable diagnostic ultrasound imaging and measurement of anatomical structures and fluids of adult and pediatric patients.
Distributed without an approved 510(k)
- 2020-04-08FDA-DeviceLeMaitre Vascular, Inc.Class ILeMaitre 5F Plus Over the Wire Embolectomy Catheter, Model Nos. 1651-84, e1651-84, 1651-88, e1651-88. The LeMaitre Over the Wire Embolectomy Catheter is indicated for use in the removal of emboli and thrombi during embolectomy and/or thrombectomy. It can also be used for catheter placement over a guidewire, vessel occlusion, fluid infusion and/or aspiration.
There has been an increased trend in reports of catheters failing to deflate during use, which may ultimately lead to tip separation.
- 2020-04-01FDA-DeviceSiemens Healthcare Diagnostics, Inc.Class IIAtellica CH Ethyl Alcohol, Test Code ETOH, Siemens Material Number (SMN) 11097501, UDI 00630414596112. The product is an ethyl alcohol assay, IVD use.
The assay may exhibit a positive bias in QC and patient results within the 10-day pack calibration interval.
- 2020-04-01FDA-DeviceRAYSEARCH LABORATORIES ABClass IIRayStation standalone software treatment planning system, Model Numbers 4.0, 4.5, 4.7, 4.9, 5.0, 6.0, 7.0, 8.0, 8.1, 9.0, 9.1 - Product Usage: RayStation is a software system for radiation therapy and medical oncology. Based on user input, RayStation proposes treatment plans. After a proposed treatment plan is reviewed and approved by authorized intended users, RayStation may also be used to administer treatments. The system functionality can be configured based on user needs.
Due to physical limitations of the treatment machine, the maximum field opening for Siemens Virtual Wedge fields recommended by the LINAC vendor will be more restricted in the wedged direction than the maximum field opening without a wedge. Delivering a larger field opening with a virtual wedge will not result in a wedged field shape over the entire field. Instead, a high dose plateau region will be the result at the toe side of the field beyond the recommended field size.
- 2020-04-01FDA-DeviceElekta Impac SoftwareClass IIMOSAIQ, oncology information system - Product Usage: MOSAIQ is an oncology information system used to manage workflows for treatment planning and delivery.
The user may inadvertently enter Metric values into Height and Weight fields labeled with US Standard Units.
- 2020-04-01FDA-DeviceMedtronic MiniMedClass IIMedtronic MiniMed Paradigm Veo Insulin pump, model numbers MMT-554CM and MMT-754CM
The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirelessly to a nearby insulin pump to change settings and control insulin delivery.
- 2020-04-01FDA-DeviceMedtronic MiniMedClass IIMedtronic MiniMed Paradigm Veo Insulin pump, model numbers MMT-554 and MMT-754
The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirelessly to a nearby insulin pump to change settings and control insulin delivery.