Medical device recalls
39226 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2019-07-24FDA-DeviceDatascope Corp.Class ICS300 Intra-Aortic Balloon Pump, English, 220V; 0998-00-3023-55 For cardiovascular use.
If battery maintenance is not performed per instructions, the battery may provide less than the minimum run time of operating power.
- 2019-07-24FDA-DeviceDatascope Corp.Class ICS300 Intra-Aortic Balloon Pump, English, 110V; 0998-00-3023-53 For cardiovascular use.
If battery maintenance is not performed per instructions, the battery may provide less than the minimum run time of operating power.
- 2019-07-24FDA-DeviceDatascope Corp.Class ICS100 Intra-Aortic Balloon Pump, English, 220V; 0998-00-3013-55 For cardiovascular use.
If battery maintenance is not performed appropriately, the battery may provide less than the minimum run time of operating power. Revised labeling and training are being provided.
- 2019-07-24FDA-DeviceDatascope Corp.Class ICS100 Intra-Aortic Balloon Pump, English, 110V; 0998-00-3013-53 For cardiovascular use.
If battery maintenance is not performed appropriately, the battery may provide less than the minimum run time of operating power. Revised labeling and training are being offered.
- 2019-07-24FDA-DeviceDatascope Corp.Class ICardiosave Rescue IABP, 0998-00-0800-83 Intra-Aortic Balloon Pump For cardiovascular use.
If battery maintenance is not performed appropriately, the battery may provide less than the minimum run time of operating power. Revised labeling and training are being provided.
- 2019-07-24FDA-DeviceDatascope Corp.Class ICardiosave Hybrid Intra-Aortic Balloon Pump (IABP), 0998-00-0800-53 For cardiovascular use.
Battery short-run times and unanticipated stoppage may be due to user not performing battery maintenance and handling as needed. Inadequate labeling is being targeted for this recall, and design updates will be handled in a subsequent recall.
- 2019-07-24FDA-DeviceTeleflex MedicalClass ITeleflex HUDSON RDI NEONATAL ConchaSmart Breathing Circuit with Dual Heated Limb and ConchaSmart Column: a) REF 870-07KIT b) REF 870-09KIT Product Usage: The Neonatal ConchaSmart breathing circuits are intended to deliver humidified breathing gases for administration to an infant/neonate patient. These gases may be delivered by nasal prongs using the CareFusion Infant Flow system and the single limb circuit, or through bypassing upper airways, for example through the use of an endotrache
Reported complaints of cracks being observed, prior to use, on swivel wye adaptors of the Neonatal ConchaSmart Breathing Circuit.
- 2019-07-24FDA-DeviceCareFusion 303, Inc.Class IAlaris Pump, Model 8100, with bezel mechanical assemblies manufactured with FR-110 plastic resin. The following products are affected by this recall as they are pumps or pump assemblies with bezels manufactured between April 2011 and June 2017 with the FR-110 plastic. Alaris Pump Module serviced with LVP Mechanism Sub Assembly (P/N 10942012, P/N 49000007, and P/N 49000203), and Alaris Pump module Bezel Kit Assembly (P/N 10964559 and P/N 49000204). Product Usage: The Alaris Pump
The bezel manufacturing process for the FR-110 plastic may have resulted in its weakening. A bezel with weakened plastic may, over time, lead to separation of the bezel post (recall issue) as well as other damage to the bezel (i.e. external cracking). The separation of one or more bezel posts may result in free flow, over infusion, under infusion or interruption of infusion.
- 2019-07-17FDA-DeviceApplied Medical Resources CorpClass IIKii Fios First Entry, 5 X 75 mm, RX only, REF CFF05 Qty: 6, Sterile R, Lot: 1330981, Exp: July 15, 2021, Applied Medical Resource Corp. Product Usage: Kii Fios first entry is indicated for use in general, abdominal, gynecological and thoracic minimally invasive surgical procedures to establish a path of entry or to gain access through tissue planes and/or potential spaces for endoscopic instruments, and as a means of insufflating the peritoneum prior to laparoscopic procedures.
The product may not have met sterility requirements . Use of a non-sterile device on a patient may expose the patient to infectious agents.
- 2019-07-17FDA-DeviceCanon Medical System, USA, INC.Class IIRadrex-i X-Ray System (DRAD-3000E) TFP-4336W (Wireless FPD) Software version: v5.00ER005 Product Usage: The RADREX-I is a general purpose x-ray system that employs Solid State Imager(s), SSXI, which converts x-rays directly into electrical signals which can, after appropriate processing be displayed on LCD monitors or printed to a medical grade image printer. The system console is PC based devise that allows for worklist management, image storage, image processing, image exporting and image
software malfunction; It was found when a user performs radiography using the wireless flat panel detector (FPD), a message window displays on the monitor stating image transmission was not completed and there was no image available. It also showed the "OK" button to reacquire image data from the FPD, and the "Cancel" button to cancel the acquisition . When the user selects the "OK" button, the same message window appears. This prompted the user to repeat the same operation several times and finally select the "Cancel" button to quit the reacquistion mode.
- 2019-07-17FDA-DeviceRichard Wolf Medical Instruments Corp.Class IIE-Line Cutting Electrode 11.5Fr Mono 0 degrees, Sterile. One electrode is placed in a plastic tray and then inserted into a Tyvek pouch. Five packaged electrodes are placed in a white box. Product Usage: Resectoscopes are used for endoscopically controlled ablation of tissue. They are used, in combination with endoscopic accessories, for examination, diagnosis, and/or therapy in various medical disciplines such as urology and gynecology.
E-Line Cutting Electrode package 8416.0305 contains E-Line Hook Electrode 8416.09 instead of E-Line Cutting Electrode 8416.03.
- 2019-07-17FDA-DeviceCOVIDIEN LLCClass IIMAHURKAR and Argyle acute hemodialysis catheters, Material numbers 8813793009 8813793013 8813794005 8813794009 8813816005 8813816009 8813817005 8813817009 8815668007 8815668011 8815668021 8815668027 8817142005 8817143005 8817145005 8817146001 8817146007 8817149007 8817232018 8817232019 8817277007 8817277011 8817277021 8817277027 8830414001 8830414002 8830415001 8830415003 8830416001 8830416003 8830416021 8830416023 8831173010 8831173011 8831173012 8831661001 8
The priming volume values printed on the MAHURKA and Argyle acute catheters and Instructions for Use (IFU) are higher than the volumes required to fill each lumen.
- 2019-07-17FDA-DeviceSiemens Medical Solutions USA, IncClass IICios care fusion system
DAP chamber may be missing an insulating foil
- 2019-07-17FDA-DeviceSiemens Medical Solutions USA, IncClass IICios Alpha VA20/ VA30 mobile X-Ray systems
DAP chamber may be missing an insulating foil
- 2019-07-17FDA-DeviceRinovum Women's HealthClass IIRevive Reusable Bladder Support, Model No. 0025 - Product Usage: The Revive bladder support is intended for temporary management of urinary leakage caused by stress urinary incontinence (SUI) in women, 18 years and older. The device comes in a sealed box, and contains a reusable bladder support and applicator, and disposable strings and travel case. The device is nonperishable and does not have an expiration date.
The product is unable to meet the use life of 31 cycles and may split or crack at the base of the "petals" after repeated use but within the use life of the product (31 uses).
- 2019-07-17FDA-DeviceHelena Laboratories, Corp.Class IIColoCARE, Cat. No. 5651, packaged 50 envelopes/box, For In-Vitro Diagnostic Use. The firm name on the label is Helena Laboratories, Beaumont, TX.
The positive control on some tests of the lots did not appropriately react within the specified timeframe to verify the test was functioning correctly.
- 2019-07-17FDA-DeviceHelena Laboratories, Corp.Class IIColoCARE, Cat. No. 5650, packaged 250 envelopes/box, For In-Vitro Diagnostic Use. The firm name on the label is Helena Laboratories, Beaumont, TX.
The positive control on some tests of the lots did not appropriately react within the specified timeframe to verify the test was functioning correctly.
- 2019-07-17FDA-DevicePhilips North America, LLCClass IIPhilips HeartStart MRx devices in use with the M3539A AC Power Module: M3535A, M3536A, M3536M, M3536MC, M3536M2, M3536M3, M3536M4, M3536M5, M3536M6, M3536M7, M3536M8, M3536M9
The AC power module may fail at a higher than expected rate. If a fully charged battery is not properly installed, the HeartStart MRx may lose all power and fail to operate. Interruption of monitoring and failure or delay in the delivery of a shock or pacing can occur. A faulty AC Power Module may also fail to charge the battery.
- 2019-07-17FDA-DeviceHamilton Medical AGClass IHAMILTON-G5, with software versions less than or equal to 2.60 The HAMILTON-G5/S1 ventilators are designed for intensive care ventilation of adult and pediatric patients, and optionally infant and neonatal patients. The device is intended for use in the hospital and institutional environment where health care professionals provide patient care.
New software version for affected ventilators reduces the probability of the ventilator entering an ambient state, in which the inspiratory channel and expiratory valves are opened, letting the patient breathe room air unassisted. When the ventilator enters the ambient state, alternative ventilation must be provided immediately.
- 2019-07-17FDA-DeviceGE Healthcare, LLCClass IPanda Infant Radiant Warmer Infant radiant warmers provide infrared heat in a controlled manner to neonates who are unable to thermo-regulate based on their own physiology. Infant radiant warmers may be used to facilitate the neonate's transition to the external environment or to provide a controlled open environment.
The bedside panels and latch areas on the Giraffe Bedded Warmer and Panda iRes Warmer can crack or break if the unit is moved using the bedside panels instead of the front handle or the maneuvering handle.
- 2019-07-17FDA-DeviceGE Healthcare, LLCClass IGiraffe Infant Radiant Warmer Infant radiant warmers provide infrared heat in a controlled manner to neonates who are unable to thermo-regulate based on their own physiology. Infant radiant warmers may be used to facilitate the neonate's transition to the external environment or to provide a controlled open environment.
The bedside panels and latch areas on the Giraffe Bedded Warmer and Panda iRes Warmer can crack or break if the unit is moved using the bedside panels instead of the front handle or the maneuvering handle.
- 2019-07-17FDA-DeviceBecton Dickinson & CompanyClass IAlaris Pump Infusion Set, Model Codes 10010453, 10010454, 10012144, 10015294, 10015414, 10933805, 11171447, 11404930, 11522558, 11607704, 10013361T, 2110-0500, 2126-0500, 2200-0500, 2411-0500, 2419-0007, 2420-0007, 2420-0500, 2421-0500, 2426-0007, 2426-0500, 2429-0500, 2433-0007, 2477-0000, 2477-0007 2478-0000 C24116E Infusion sets allow for the intravenous administration of fluids, medications, nutritional support and transfusion therapy through a needle or catheter inserted into the patient
An incomplete occlusion can be caused by a variation in the wall thickness of the pumping segment of the affected infusion sets used with the. The issue has the potential to lead to unintended delivery of medication when the pump module is not in running status or can result in faster than expected drug delivery flow when the pump is infusing.
- 2019-07-10FDA-DeviceZimmer Biomet, Inc.Class IIK-Wire Trochar Tip, Model Number 212000008 Product Usage: These DVR Express Disposable Instruments are used to facilitate implantation of orthopedic medical devices in trauma.
There is a potential for weak seals of the sterile packaging.
- 2019-07-10FDA-DeviceZimmer Biomet, Inc.Class IIDVR Crosslock ePAK Depth Gauge, Model Number 212000003 Product Usage: These DVR Express Disposable Instruments are used to facilitate implantation of orthopedic medical devices in trauma.
There is a potential for weak seals of the sterile packaging.
- 2019-07-10FDA-DeviceZimmer Biomet, Inc.Class IIDVR Crosslock ePAK Screw Driver, Model Number 212000002 Product Usage: These DVR Express Disposable Instruments are used to facilitate implantation of orthopedic medical devices in trauma.
There is a potential for weak seals of the sterile packaging.
- 2019-07-10FDA-DeviceBio-Detek, Inc.Class IIZOLL Pro-padz Liquid Gel Radiolucent, Part numbers: 8900-2105-01 (12/case) and 8900-2106-01 (single)
Some of the electrodes may have been assembled incorrectly, preventing delivery of defibrillation or pacing therapy.
- 2019-07-10FDA-DeviceCardiac Science CorporationClass IIPowerheart¿ G5 Automatic AED
Sub-supplier s documentation for specific Printed Circuit Boards (PCB) is insufficient to determine if the devices conform to specifications.
- 2019-07-10FDA-DeviceBeckman Coulter Inc.Class IIiChem VELOCITY Urine Chemistry Strips, REF 800-7212, 100 test strips/vial. The firm name on the label is Beckman Coulter Ireland, Inc., Co. Clare, Ireland, Made in Germany.
Falsely elevated (false positive) urobilinogen patient results due to an increase in the sensitivity of the urobilinogen reaction.
- 2019-07-10FDA-DeviceOrtho-Clinical DiagnosticsClass IIVITROS 350 Chemistry System, Product Code 6802153, (UDI # 10758750002054) Product Usage: Performs discrete clinical tests on serum, urine, and cerebral spinal fluid specimens. Methodologies include colorimetric (CM), potentiometric (PM), rate (RT), and immuno-rate (IR) tests using multi-layered VITROS Slides.
Potential negative drift in Creatine Kinase (CK) results when used on the VITROS 250 and 350 Systems.
- 2019-07-10FDA-DeviceOrtho-Clinical DiagnosticsClass IIVITROS 250 Chemistry System Refurbished, Product Code 6801759, (UDI # 10758750001330) Product Usage: Performs discrete clinical tests on serum, urine, and cerebral spinal fluid specimens. Methodologies include colorimetric (CM), potentiometric (PM), rate (RT), and immuno-rate (IR) tests using multi-layered VITROS Slides.
Potential negative drift in Creatine Kinase (CK) results when used on the VITROS 250 and 350 Systems.