Medical device recalls
38684 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2024-11-06FDA-DeviceIntegra LifeSciences Corp.Class IIMICR PATIE RND Model/Catalog Number: 801396. CODMAN Surgical Patties and CODMAN Surgical Strips are manufactured of COTTONOID¿ Material with x-ray detectable markers. All patties have a suture string attached for ease in performing postsurgical count verification. The surgical patties and surgical strips are indicated for the use in protection of tissue, including brain and other tissues of the central nervous system, during surgery.
Identified higher-than-expected levels of endotoxin within the raw material used to produce Codman Surgical Patties and Strips that may have resulted in out-of-specification levels of endotoxin in finished goods
- 2024-11-06FDA-DeviceAbbott Molecular, Inc.Class IIAbbott Alinity m STI AMP Kit, used with the Alinity m System, product codes: a) REF 09N17-095; b) REF 09N17-090; c) REF 09N17-091;
Abbott has identified an increase of incidences regarding Error Code (EC) 9198 (Positive control is non-reactive) while using the Alinity m HR HPV AMP Kit and Alinity m STI AMP Kit. Certain invalidated positive assay controls can be traced to iron leaching into the Alinity m Lysis Solution from the lysis transfer pump in the Alinity m System.
- 2024-11-06FDA-DeviceAbbott Molecular, Inc.Class IIAbbott Alinity m HPV AMP Kit, used with the Alinity m System, product codes: a) REF 09N15-095; b) REF 09N15-090; c) REF 09N15-091
Abbott has identified an increase of incidences regarding Error Code (EC) 9198 (Positive control is non-reactive) while using the Alinity m HR HPV AMP Kit and Alinity m STI AMP Kit. Certain invalidated positive assay controls can be traced to iron leaching into the Alinity m Lysis Solution from the lysis transfer pump in the Alinity m System.
- 2024-11-06FDA-DeviceOlympus Corporation of the AmericasClass IIQuest Spectrum 3 Fluorescent Imaging System Model/Catalog Number: ART-SYS-0029, ART-SYS-0030 The Quest Spectrum3 is a fluorescent imaging system used in capturing and viewing fluorescent images for the visual assessment of blood flow for the evaluation of tissue perfusion, and related tissue-transfer circulation in tissue and free flaps used during plastic and reconstructive surgeries.
Does not meet the requirements for electromagnetic compatibility (EMC) of the standard IEC 60601-1-2. Electromagnetic interference occurring during a procedure may cause the device to malfunction requiring the replacement of the device. This could potentially result in a prolonged procedure and/or require additional medical intervention
- 2024-11-06FDA-DeviceImaCor Inc.Class IIClariTEE Probe- Miniature transesophageal echo ultrasound probe for use with ImaCor ultrasound diagnostic platforms. Model/Catalog Number: CLT-010, CLT-010-1
Epoxy used to seal the edge of the transducer into its paddle exceeded specification. This variability could attenuate the ultrasound signal with a potential impact on the quality of images obtained from the probes.
- 2024-11-06FDA-DevicePhysio-Control, Inc.Class IILIFEPAK 15 (LP15) Model/Catalog Numbers: o 97577-000101 o 99577-000046 o 99577-000055 o 99577-000061 o 99577-000076 o 99577-001250 o 99577-001255 o 99577-001256 o 99577-001368 o 99577-001955 o 99577-001956 o 99577-001957 o 99577-001958 o 99577-001962 LIFEPAK 15 intended use monitor/defibrillator.
Due to an out of tolerance tool being used on monitor/defibrillator systems.
- 2024-11-06FDA-DeviceOlympus Corporation of the AmericasClass IIOlympus Endoscopic Flushing Pump, Model/Catalog Number: OFP-2 (K10001141)
During product testing, Olympus identified an intermittent loss of function of the OFP-2 Flushing Pump caused by an internal component connection failure.
- 2024-11-06FDA-DeviceBaxter Healthcare CorporationClass IIa. Hillrom Centrella Smart+ Medical-Surgical Hospital Bed, Product codes: P7900B000001, P7900B100010, P7900B100024, P7900B100208, P7900B100273, P7900B100304, P7900B000005, P7900B100011, P7900B100025, P7900B100212, P7900B100277, P7900B100307, P7900B000010, P7900B100017, P7900B100026, P7900B100222, P7900B100281, P7900B1SPL05, P7900B000011, P7900B100018, P7900B100028, P7900B100223, P7900B100287, P7900B1SPL06, P7900B000020, P7900B100019, P7900B100039, P7900B100224, P7900B100288, P7900B000022, P790
The beds have a potential for an interface issue with the Rauland Responder 5 Nurse Call System where the bed exit system will alert at the bed, but may fail to send a remote alert through the nurse call system.
- 2024-11-06FDA-DeviceSmiths Medical ASD Inc.Class ICADD-Solis Li-ion Rechargeable Battery Packs, REF 21-2160-XX, which are also sold as a component of the following CADD Solis Ambulatory Infusion Systems: 21-2101-0100-50, 21-2101-0200-02, 21-2101-0200-03, 21-2101-0200-06, 21-2101-0200-07, 21-2101-0200-12, 21-2101-0200-14, 21-2101-0200-17, 21-2101-0200-238, 21-2101-249, 21-2101-51, 21-2102-0200-02, 21-2102-249, 21-2102-51, 21-2111-0100-00, 21-2111-0100-50, 21-2111-0100-51, 21-2111-0200-02, 21-2111-0200-03, 21-2111-0200-06, 21-2111-0200-07, 21-21
Damage to the battery pack may have caused a short to a capacitor within the battery pack. While the battery encasement is designed to be flame retardant, a short to the capacitor could lead to melting of the battery pack case. If this issue occurs, the battery pack charging circuit may become inoperable.
- 2024-11-06FDA-DevicePercussionaire CorporationClass IPhasitron5 Breathing Circuit (P5-10, P5-HC, P5-UC-10). component of Intrapulmonary Percussive Ventilation, used to provide airway clearance therapy
As a result of product complaints, breathing circuits are experiencing discolored fluid which are formed when therapy was being given with specific medication through the nebulizer cup. Discoloration is caused by a reaction between medicated mist and an inadvertent/unapproved addition of a nickel coating on the spring component.
- 2024-11-06FDA-DeviceDATEX--OHMEDA, INC.Class IGE Healthcare Giraffe Incubator Carestation CS1, Infant Incubator. Model Numbers: 1) 2082844-002-01040417; 2) 2082844-002-01044956; 3) 2082844-002-01058424; 4) 2082844-002-01069017; 5) 2082844-002-01089666; 6) 2082844-002-01090474; 7) 2082844-002-01091269; 8) 2082844-002-01093489; 9) 2082844-002-01113262; 10) 2082844-002-01113711; 11) 2082844-002-01123085; 12) 2082844-002-01123918; 13) 2082844-002-01128966; 14) 2082844-002-01133042; 15) 2082844-002-01146447; 16)
Prior to current established manufacturing practices, higher levels of airborne formaldehyde exposure from newly manufactured incubators could be seen during clinical use that would rapidly decrease over a week. Affected customers were notified in June 2023 to run incubators for a week to potentially off gas any residual airborne formaldehyde. The general scientific consensus is that sensory irritation of the eyes is the most sensitive endpoint with respect to exposure to airborne formaldehyde and is the adverse effect clinically experienced at the lowest concentration.
- 2024-11-06FDA-DeviceDATEX--OHMEDA, INC.Class IGE Healthcare Giraffe Omnibed Carestation CS1, combination infant incubator and infant warmer. Model Numbers: 1) 2082844-001-01040418; 2) 2082844-001-01046784; 3) 2082844-001-01052324; 4) 2082844-001-01052572; 5) 2082844-001-01055337; 6) 2082844-001-01065693; 7) 2082844-001-01069008; 8) 2082844-001-01073750; 9) 2082844-001-01086553; 10) 2082844-001-01089393; 11) 2082844-001-01090414; 12) 2082844-001-01092632; 13) 2082844-001-01111482; 14) 2082844-001-01115741; 15)
Prior to current established manufacturing practices, higher levels of airborne formaldehyde exposure from newly manufactured incubators could be seen during clinical use that would rapidly decrease over a week. Affected customers were notified in June 2023 to run incubators for a week to potentially off gas any residual airborne formaldehyde. The general scientific consensus is that sensory irritation of the eyes is the most sensitive endpoint with respect to exposure to airborne formaldehyde and is the adverse effect clinically experienced at the lowest concentration.
- 2024-11-06FDA-DeviceMaquet Cardiovascular, LLCClass IVasoView HemoPro Endoscopic Vessel Harvesting System, Product Codes VH-3000-W and VH-3500
There were reports of the silicone detaching from the Jaws of the Harvesting Tool during use.
- 2024-10-30FDA-DeviceBoston Scientific CorporationClass IIBoston Scientific myLUX Patient Application for an Apple Mobile device, Model Number 2939, Version 2.0.101, 2.0.110, cardiac monitor application.
Patients using the Model 2939 myLUX Patient Application on their Apple mobile device (e.g., iPhone) may not be transmitting data from their Insertable Cardiac Monitor to the LATITUDE Clarity website.
- 2024-10-30FDA-DeviceOlympus Corporation of the AmericasClass IIEZDilate Wire Guided Balloon- Indicated for use in adult and adolescent (> 12 years) populations to endoscopically dilate strictures of the alimentary tract. It is also indicated in adults for endoscopic dilatation of the Sphincter of Oddi with or without prior sphincterotomy. Model/Catalog Number: BD-410X-1055
Mislabeled Glo Cath Label (attached to the device) states: 11 mm, 12 mm, 13 mm however the balloon is 8.5mm, 9.5mm and 10.5 mm and may result in prolonged surgery. All other labeling is correct for the balloon, including the Shelf Box with Front Box Label and Circular Star Label and the balloon Pouch
- 2024-10-30FDA-DeviceSpectrum Medical Ltd.Class IIQuantum Perfusion Systems for CPB, Roller Pumps use peristaltic action to propel blood through the venous and arterial circuit tubing. Catalog Numbers: a) 51-000013-00, b) 51-000008-00
The ratchet and pawl had an out of tolerance geometry which exhibited as the left bobbin would not lock.
- 2024-10-30FDA-DevicePolymer Technology Systems, Inc. dba PTS Diagnostics, Inc.Class IIA1CNow+ Multi-Test HbA1c System consists of (1) a semi-disposable plastic-encased device (the monitor), (2) a plastic cartridge enclosing dry reagent strips, and (3) a sample dilution kit for: collecting the blood sample, mixing the sample with the required pre-treatment solution, and delivering the sample to the cartridge.
The reason for this recall is PTS Diagnostics, Inc. received complaints of non-matching cartridge and analyzer codes within the product test system box. Use of cartridges and analyzers with non-matching codes may result in inaccurate test results as components within each lot number are meant to be used together, and not mixed between lots. Therefore, the test results may possibly lead to Hemoglobin A1C positive or negative bias results. While the product is for monitoring only, over recovery with a higher than accurate value can be an indication for increased therapy; such as physical activity, weight reduction, meal management, pharmaceutical therapy.
- 2024-10-30FDA-DeviceAd-Tech Medical Instrument CorporationClass IIAD-TECH Spencer Probe Depth Electrode, REF SD08R-AP58X-000 8-Contact 1.12mm (A style) Depth Electrode
Ad-Tech is recalling these A-Style SD Depth Electrodes because a label discrepancy was identified on A style contact SD electrodes where the MR Conditional symbol was incorrectly placed instead of the MR Unsafe symbol. The A style contacts were not cleared for MR Conditional use. Our records indicate you have received one or more of the affected lots listed above.
- 2024-10-30FDA-DeviceAd-Tech Medical Instrument CorporationClass IIAD-TECH Spencer Probe Depth Electrode, REF SD06R-AP58X-000 6-Contact 1.12mm (A style) Depth Electrode
Ad-Tech is recalling these A-Style SD Depth Electrodes because a label discrepancy was identified on A style contact SD electrodes where the MR Conditional symbol was incorrectly placed instead of the MR Unsafe symbol. The A style contacts were not cleared for MR Conditional use. Our records indicate you have received one or more of the affected lots listed above.
- 2024-10-30FDA-DeviceAd-Tech Medical Instrument CorporationClass IIAD-TECH Spencer Probe Depth Electrode, REF SD04R-AP58X-000 4-Contact 1.12mm (A style) Depth Electrode
Ad-Tech is recalling these A-Style SD Depth Electrodes because a label discrepancy was identified on A style contact SD electrodes where the MR Conditional symbol was incorrectly placed instead of the MR Unsafe symbol. The A style contacts were not cleared for MR Conditional use. Our records indicate you have received one or more of the affected lots listed above.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000 U14 (MBW) V, Product code REF 2065386
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000 U14 (MBW), Product code REF 2065385
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000 (dV) V, Product code REF 1841083
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000 (MBW) V, Product code REF 1841082
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000 V, Product code REF 1841050
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000 (dV), Product code REF 1841049
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000 (MBW), Product code REF 1841048
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating Table TruSystem 7000, Product code REF 1841046
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBaxter Healthcare CorporationClass IIBaxter Operating table TruSystem 7000 U (MB), Product codes: a) REF 1604786; b) REF 1604788; c) REF 1723633
The firm received customer reports stating that the batteries and their connectors experienced electrical short-circuits and/or emitted smoke.
- 2024-10-30FDA-DeviceBlue OrthoClass IIPredict+ is a data-driven, clinical decision support tool that uses machine learning to provide predictions of individual patient outcomes after shoulder replacement surgery
Predict+ is being recalled for lack of pre-market clearance/approval.