- 2022-05-04FDA-DeviceROi CPS LLCClass IIConvenience kits containing regard IV Start Kits: (1) regard Clinical Packaging Solutions, Item Number: 830014015, LD00199O - C Section Mother; and (2) regard Clinical Packaging Solutions, Item Number: 830014016, LD00199P - C Section Mother.
A drug kit component was recalled by its manufacturer due to the potential for inadequacy of the validation of test methods used in its manufacture.
- 2022-05-04FDA-DeviceBoston Scientific CorporationClass IISpaceOAR Vue System, UPN SV-1010 and SV-2101. Used to temporarily position the anterior rectal wall away from the prostate during radiotherapy for prostate cancer to reduce the radiation dose delivered to the anterior rectum.
Users need to be aware that embolism is a possible adverse event associated with hydrogel misplacements. Updated IFU provides new procedural instructions, warnings and precautions that describe steps to verify correct placement of the hydrogel following implantation, as well as technique recommendations for the proper placement of SpaceOAR and SpaceOAR Vue.
- 2022-05-04FDA-DeviceBoston Scientific CorporationClass IISpaceOAR System, UPN SO-1010, SO-2101, SO-3101, and SO-4101. Used to temporarily position the anterior rectal wall away from the prostate during radiotherapy for prostate cancer to reduce the radiation dose delivered to the anterior rectum.
Users need to be aware that embolism is a possible adverse event associated with hydrogel misplacements. Updated IFU provides new procedural instructions, warnings and precautions that describe steps to verify correct placement of the hydrogel following implantation, as well as technique recommendations for the proper placement of SpaceOAR and SpaceOAR Vue.
- 2022-05-04FDA-DeviceSight Sciences, Inc.Class IITearCare version 1.0 SmartHubs
Ophthalmic devices distributed prior to the recently-obtained 510(k) clearance do not fall within the relevant 510(k) exemption and so their performance characteristics were not evaluated by the FDA prior to distribution.
- 2022-05-04FDA-DeviceNeuMoDx Molecular IncClass IINeuMoDx Cartridge-For in vitro diagnostic use with NeuMoOx Molecular Systems with either of the following assays: NeuMoDx SARS CoV-2 Test Strip (REF 300800) NeuMoDx Flu A-B/RSV/SARS-CoV-2 Vantage Test Strip (REF 300900) NeuMoDx Laboratory Developed Tests (LDTs) for SARS-CoV-2 RNA detection Note: Results for targets other than SARS-CoV-2 are not impacted by this Urgent Medical Device Correction Ref. Number: 100100
Potential for false positive results for SARS-CoV-2 in identified lots of cartridges, when used in conjunction with assays containing SARS-CoV-2 targets (NeuMoDx" SARS-CoV-2 Test Strip Cat #300800 and NeuMoDx" Flu A-B/RSV/SARS-CoV-2 Vantage Assay Cat #300900) result incorrect management of patients
- 2022-05-04FDA-DeviceIntuitive Surgical, Inc.Class IIda Vinici X da Vinci Xi Sureform 45 REF 480445 da Vinci X da Vinci Xi Sureform 45 Curved-Tip REF 480545 da Vinici X da Vinci Xi Sureform 60 REF 480460
As a result of complaint data review, it identified tissue pushout events occurring during firing of the SureForm stapler when tissue is pushed distally within the jaws, rather than being held in place and transected. Overall rate of harm associated with bleeding of critical severity exceeds the predicted likelihood of harm as documented within Intuitives existing risk documentation.
- 2022-05-04FDA-DeviceMedtronic NeuromodulationClass IIMEDTRONIC INTERSTIM THERAPY SYSTEM FOR URINARY CONTROL, which includes the following: a) Handset with Communicator, Model Numbers: 1) TH90Q01, 2) TH90QFA, 3) TH90PFA, 4) TH90GFA, 5) TG90G01; b) InterStim X Clinician Therapy Application Software, Model Number A51300; and c) InterStim x "My Therapy" Patient Therapy Application Software, Model Number A52300
There is a software anomaly with the InterStim X Clinician software application with results in the data entered in the Patient Information fields not e retained and a " Data Lost" notification being displayed.
- 2022-05-04FDA-DeviceSiemens Medical Solutions USA, IncClass IIsyngo.via RT Image Suite upgraded to VB60 running on SOMATOM go.Open Pro Model Number 11061670. Running on servers with syngo.via VB60 software after upgrade and CT scanners with syngo.CT VA40A after upgrade.
Upgraded software version makes an automatic change in laser configuration settings for "markerless workflow" which may lead to the wrong laser offset coordinates being displayed in the Patient Marking step.
- 2022-05-04FDA-DeviceSiemens Medical Solutions USA, IncClass IIsyngo.via RT Image Suite upgraded to VB60 running on SOMATOM go.Sim Model Number 11061660. Running on servers with syngo.via VB60 software after upgrade and CT scanners with syngo.CT VA40A after upgrade.
Upgraded software version makes an automatic change in laser configuration settings for "markerless workflow" which may lead to the wrong laser offset coordinates being displayed in the Patient Marking step.
- 2022-05-04FDA-DeviceSiemens Medical Solutions USA, IncClass IIsyngo.via RT Image Suite upgraded to VB60 running on SOMATOM go.Up Model Number 11061620. Running on servers with syngo.via VB60 software after upgrade and CT scanners with syngo.CT VA40A after upgrade.
Upgraded software version makes an automatic change in laser configuration settings for "markerless workflow" which may lead to the wrong laser offset coordinates being displayed in the Patient Marking step.
- 2022-05-04FDA-DeviceSiemens Medical Solutions USA, IncClass IIsyngo.via RT Image Suite upgraded to VB60 running on syngo.via Model Number 10496180. Running on servers with syngo.via VB60 software after upgrade and CT scanners with syngo.CT VA40A after upgrade.
Upgraded software version makes an automatic change in laser configuration settings for "markerless workflow" which may lead to the wrong laser offset coordinates being displayed in the Patient Marking step.
- 2022-05-04FDA-DeviceBaxter Healthcare CorporationClass IIPrisMax System, Product Codes: a) 955558, b) 955627, c) 955701
This correction is due to software anomalies occurring during use. If the operator initiates therapy by entering a value other than the default value for the patient Gain/Loss Limit or the Return Pressure Drop Limit (RDL) and uses the Same Patient function, the PrisMax System will return the patient Gain/Loss Limit or the RDL to the default value, rather than the non-default value entered at the initiation of treatment. The PrisMax System interface will display the original values once treatment is restarted but does not have an alert to inform the user of the change. The RDL value will be returned to the original value immediately upon selecting the Same Patient function. The Gain/Loss Limit value will be returned to the original value when the patient weight and/or hematocrit is changed during treatment.
- 2022-05-04FDA-DeviceBaxter Healthcare CorporationClass IIPrisMax System, Product Code 955724
This correction is due to software anomalies occurring during use. If the operator initiates therapy by entering a value other than the default value for the patient Gain/Loss Limit or the Return Pressure Drop Limit (RDL) and uses the Same Patient function, the PrisMax System will return the patient Gain/Loss Limit or the RDL to the default value, rather than the non-default value entered at the initiation of treatment. The PrisMax System interface will display the original values once treatment is restarted but does not have an alert to inform the user of the change. The RDL value will be returned to the original value immediately upon selecting the Same Patient function. The Gain/Loss Limit value will be returned to the original value when the patient weight and/or hematocrit is changed during treatment.
- 2022-05-04FDA-DeviceBaxter Healthcare CorporationClass IIPrisMax System, Product Code 955626
This correction is due to software anomalies occurring during use. If the operator initiates therapy by entering a value other than the default value for the patient Gain/Loss Limit or the Return Pressure Drop Limit (RDL) and uses the Same Patient function, the PrisMax System will return the patient Gain/Loss Limit or the RDL to the default value, rather than the non-default value entered at the initiation of treatment. The PrisMax System interface will display the original values once treatment is restarted but does not have an alert to inform the user of the change. The RDL value will be returned to the original value immediately upon selecting the Same Patient function. The Gain/Loss Limit value will be returned to the original value when the patient weight and/or hematocrit is changed during treatment.
- 2022-05-04FDA-DeviceMedtronic formerly CovidienClass IPuritan Bennett 980 Series Ventilator
The audible alarm may not sound and/or the omni-directional LED visual alarm may not display during alarm states. Delayed awareness of alarm states may lead to delayed response or a delay of treatment, potentially resulting in hypoxia, dyspnea, cardiac arrest, or death.
- 2022-05-04FDA-DeviceCELLTRION USA INCClass ICelltrion DiaTrust COVID-19 Ag Rapid Test, Reference No. CT-P60 D-2 02
Point of Care (PoC) rapid test products were distributed to customers who did not have a valid CLIA ID.
- 2022-04-27FDA-DeviceSt. Jude Medical, Cardiac Rhythm Management DivisionClass IIGallant HF Implantable Cardioverter Defibrillator REF# CDHFA500Q
Bluetooth malfunction impacting Gallant devices post-implant. The failure causes the device to enter an inductive-only telemetry mode with a loss of Bluetooth communication. The Bluetooth malfunction results in the inability to remotely monitor these devices and resulted in reduced battery longevity.
- 2022-04-27FDA-DeviceSt. Jude Medical, Cardiac Rhythm Management DivisionClass IIGallant VR Implantable Cardioverter Defibrillator REF # CDVRA500Q
Bluetooth malfunction impacting Gallant devices post-implant. The failure causes the device to enter an inductive-only telemetry mode with a loss of Bluetooth communication. The Bluetooth malfunction results in the inability to remotely monitor these devices and resulted in reduced battery longevity.
- 2022-04-27FDA-DeviceSt. Jude Medical, Cardiac Rhythm Management DivisionClass IIGallant DR Implantable Cardioverter Defibrillator REF # CDDRA500Q
Bluetooth malfunction impacting Gallant devices post-implant. The failure causes the device to enter an inductive-only telemetry mode with a loss of Bluetooth communication. The Bluetooth malfunction results in the inability to remotely monitor these devices and resulted in reduced battery longevity.
- 2022-04-27FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis pheno- in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). Intended use-single and biplane diagnostic imaging and interventional procedures. Model: 10849000
Five potential software issues affecting Artis pheno and Artis icono systems in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). The potential software errors are related to the block movements function and manual rotation of the flat detector. Depending on the status of the intervention, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where clinical treatment may be delayed until an additional restart is performed
- 2022-04-27FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis icono floor in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). Intended use single and biplane diagnostic imaging and interventional procedures. Model: 11327700
Five potential software issues affecting Artis pheno and Artis icono systems in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). The potential software errors are related to the block movements function and manual rotation of the flat detector. Depending on the status of the intervention, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where clinical treatment may be delayed until an additional restart is performed
- 2022-04-27FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis icono biplane- in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). Intended use single and biplane diagnostic imaging and interventional procedures. Model: 11327600
Five potential software issues affecting Artis pheno and Artis icono systems in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). The potential software errors are related to the block movements function and manual rotation of the flat detector. Depending on the status of the intervention, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where clinical treatment may be delayed until an additional restart is performed
- 2022-04-27FDA-DeviceBeckman Coulter, Inc.Class IIIBeckman Coulter IRISpec CA/CB/CC control, Catalog #800-7211, containing 3 x 100 mL bottles each of CA Control, CB Control, and CC Control.
IRISpec CA failures for glucose.
- 2022-04-27FDA-DeviceGE Healthcare, LLCClass IIGE Healthcare MR Systems, Magnetic Resonance imaging (MRI). SIGNA Premier, SIGNA Architect, SIGNA Pioneer, Discovery MR750w 3.0T, Discovery MR750 3.0T, SIGNA PET/MR, 1.5T SIGNA Creator, 1.5T SIGNA Explorer, 1.5T SIGNA MR355, 1.5T SIGNA MR360, 1.49T SIGNA MR380, SIGNA Voyager, SIGNA Voyager Premier Edition, SIGNA Artist, Optima MR450w 1.5T, Optima MR450w GEM, Discovery MR450 1.5T, GE 1.5T and 3.0T SIGNA HDx, GE 1.5T and 3.0T SIGNA HDxt, 1.5T and 3.0T SIGNA HDxt Mobile, SIGNA HDi, SIGNA Vibrant
During the de-installation of an MR system magnet, if all rigging and hardware that attach to the magnet for transportation are not properly installed and secured, the magnet may fall, leading to potential injury.
- 2022-04-27FDA-DeviceDNA Genotek Inc.Class IIORAcollect RNA: ORE-100
Evaporation of stabilizing liquid reducing shelf life.
- 2022-04-27FDA-DeviceDNA Genotek Inc.Class IIORAcollect Dx, Catalog Number/SKU: OCD-100, OCD-100A. Material numbers: OCD-100, OCD-100.008, OCD-100.012, OCD-100.014+ACP078, OCD-100.014+ACP078, OCD-100.032 and OCD-100A, OCD-100A.022, OCD-100A.023, OCD-100A.024, OCD-100A.025
Evaporation of stabilizing liquid reducing shelf life.
- 2022-04-27FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis Q.zen biplane, Model Number 10848355
If the coolant level in the cooling circuit drops below a certain level, this may result in a situation in which the X-ray tube is no longer sufficiently cooled and the system will display the message "TUBE HOT, have a break". Several minutes later the system will block X-ray to prevent further damage and display the message "NO XRAY: TUBE TOO HOT".
- 2022-04-27FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis Q.zen ceiling, Model Number 10848354
If the coolant level in the cooling circuit drops below a certain level, this may result in a situation in which the X-ray tube is no longer sufficiently cooled and the system will display the message "TUBE HOT, have a break". Several minutes later the system will block X-ray to prevent further damage and display the message "NO XRAY: TUBE TOO HOT".
- 2022-04-27FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis Q.zen floor, Model Number 10848353
If the coolant level in the cooling circuit drops below a certain level, this may result in a situation in which the X-ray tube is no longer sufficiently cooled and the system will display the message "TUBE HOT, have a break". Several minutes later the system will block X-ray to prevent further damage and display the message "NO XRAY: TUBE TOO HOT".
- 2022-04-27FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis Q zeego, Model Number 10848283
If the coolant level in the cooling circuit drops below a certain level, this may result in a situation in which the X-ray tube is no longer sufficiently cooled and the system will display the message "TUBE HOT, have a break". Several minutes later the system will block X-ray to prevent further damage and display the message "NO XRAY: TUBE TOO HOT".