Medical device recalls
39180 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2020-01-08FDA-DeviceRoche Diabetes Care, Inc.Class IIBlood Glucose Monitoring System, Model Number 08453063001 ACCU-CHEK GUIDE SAMPLE KIT FCN MG/DL US - Product Usage: The Accu-Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control. The Accu-Chek Guide blood Glucose Monitoring System is intended for in vitro diagnostic single-patient use by people with diabetes. The Accu-Chek Guide B
Potential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.
- 2020-01-08FDA-DeviceRoche Diabetes Care, Inc.Class IIBlood Glucose Monitoring System, Model Number 08453071001 ACCU-CHEK GUIDE RETAIL KIT FCN MG/DL US - Product Usage: The Accu-Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control. The Accu-Chek Guide blood Glucose Monitoring System is intended for in vitro diagnostic single-patient use by people with diabetes. The Accu-Chek Guide B
Potential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.
- 2020-01-08FDA-DeviceRoche Diabetes Care, Inc.Class IIBlood Glucose Monitoring System, Model Number 07400942001 ACCU-CHEK GUIDE METER ONLY MG/DL US - Product Usage: The Accu-Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control. The Accu-Chek Guide blood Glucose Monitoring System is intended for in vitro diagnostic single-patient use by people with diabetes. The Accu-Chek Guide Blood
Potential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.
- 2020-01-08FDA-DeviceRoche Diabetes Care, Inc.Class IIBlood Glucose Monitoring System, Model Number 07400926001 ACCU-CHEK GUIDE RETAIL KIT MG/DL - Product Usage: The Accu-Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control. The Accu-Chek Guide blood Glucose Monitoring System is intended for in vitro diagnostic single-patient use by people with diabetes. The Accu-Chek Guide Blood Gl
Potential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.
- 2020-01-08FDA-DeviceRoche Diabetes Care, Inc.Class IIBlood Glucose Monitoring System, Model Number 07400870001 ACCU-CHEK GUIDE SAMPLE KIT MG/DL - Product Usage: The Accu-Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control. The Accu-Chek Guide blood Glucose Monitoring System is intended for in vitro diagnostic single-patient use by people with diabetes. The Accu-Chek Guide Blood Gl
Potential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.
- 2020-01-08FDA-DeviceThoratec Corp.Class IIHeartMate 3 Mobile Power Unit, REF 107754, UDI or GTIN: 00813024010883, and 107758, UDI or GTIN: 00813024010890, when connected to the HeartMate 3 Left Ventricular Assist System, REF 106524US, UDI or GTIN: 00813024013297, and 106524, UDI or GTIN: 00813024011712 - Product Usage: Provides power to the System Controller and pump. - Provides power to the System Monitor when it is connected to the Power Module. - Connects the System Monitor to the System Controller for monitoring purposes. - Echoes S
Excessive static electricity can potentially cause unrecoverable power loss and damage to the mobile power unit that can be used to power the left ventricular assist system, which could lead to no or reduced blood flow from the left ventricular assist system.
- 2020-01-08FDA-DeviceSTANLEY BLACK & DECKER INC.Class IIThe products involved are DeWALT laser distance measurers, model numbers DW0165, DW0165S, DW0330S and Stanley Fatmax FMHT77506. These products were produced for DeWALT and Stanley by a contract manufacturer.
The products are labeled as Class II lasers. However, the level of laser radiation emitted by the distributed products may exceed the limit (1 mW) established for Class II lasers. These products would be more appropriately classified into laser Class IIIa (IEC Laser Class IIIR).
- 2020-01-01FDA-DeviceTosoh Smd IncClass IIIAIA-PACK B12 Pretreatment Set- IVD for diagnostic use for pre-treatment of calibrators/controls. Part Number: 020706
The AIA-2000 bar code scanners depend on the quiet zone to help identify the bar code. The lack of an adequate quiet zone can cause the bar code scanner to confuse the bar codes with text or graphics resulting in the scanner ignoring a valid symbol. This results in an error in reading the barcode: Error Code 2220 Unable to read barcode on reagent bottle. In some cases, the quiet zone is too short and an error in barcode reading occurs. The problem is intermittent and not all vials (6 vials are available per set) have been reported to fail. The only risk to patients or users is a delay in results. The company recommends (optional) that customers pre-screen the vials to identify affected products. Customers can contact the company for reimbursement of any affected products. The company has implemented barcode checks as a temporary solution and will replace the barcode printer on the production line for products beginning with lot B*01898.
- 2020-01-01FDA-DeviceAxis-Shield Diagnostics, Ltd.Class IIAxis-Shield Liquid Stable (LS) 2-Part HOMOCYSTEINE REAGENT, Part Number FHRWR1000 - Product Usage: The device can assist in the diagnosis and treatment of patients suspected of having hyperhomocysteinemia and homocystinuria. The device is intended for Professional use only.
There is a potential performance issue as detected by an under-recovery of sample results during routine testing.
- 2020-01-01FDA-DeviceAxis-Shield Diagnostics, Ltd.Class IIAxis-Shield Liquid Stable (LS) 2-Part HOMOCYSTEINE REAGENT, Part Number FHRWR100 - Product Usage: The device can assist in the diagnosis and treatment of patients suspected of having hyperhomocysteinemia and homocystinuria. The device is intended for Professional use only.
There is a potential performance issue as detected by an under-recovery of sample results during routine testing.
- 2020-01-01FDA-DeviceAxis-Shield Diagnostics, Ltd.Class IIAxis-Shield Liquid Stable (LS) 2-Part HOMOCYSTEINE REAGENT, Part Number FHBC100 - Product Usage: The device can assist in the diagnosis and treatment of patients suspected of having hyperhomocysteinemia and homocystinuria. The device is intended for Professional use only.
There is a potential performance issue as detected by an under-recovery of sample results during routine testing.
- 2020-01-01FDA-DevicePolymer Technology Systems, Inc.Class IIPTS Panels CHOL+HDL+GLU Test Strips, Reference Number 5412, for use on CardioChek PA or CardioChek Plus analyzers
This lot of test strips is showing an under-recovery when tested against a reference method.
- 2020-01-01FDA-DeviceOrtho Clinical Diagnostics IncClass IIUrine Electrolyte Diluent, Product Code: 1112352 - Product Usage: used to dilute urine specimens for analysis of sodium (Na+) and potassium (K+) on VITROS 250/350/5,1 FS/4600 Chemistry Systems and the VITROS 5600/XT 7600 Integrated Systems.
Potential for the instability of the diluents VITROS 7% BSA (Product Code 8262487) and VITROS Urine Electrolyte Diluent (UED) (Product Code 1110352) when stored in a 2mL cup for 7 days.
- 2020-01-01FDA-DeviceOrtho Clinical Diagnostics IncClass II7% BSA (Bovine Serum Albumin), Product Code: 8262487 - Product Usage: is used to dilute samples when assay values exceed the reportable (dynamic) range using the VITROS 250/350/5,1 FS/4600 Chemistry Systems and VITROS 5600/XT 7600 Integrated Systems.
Potential for the instability of the diluents VITROS 7% BSA (Product Code 8262487) and VITROS Urine Electrolyte Diluent (UED) (Product Code 1110352) when stored in a 2mL cup for 7 days
- 2020-01-01FDA-DeviceDiagnostica Stago, Inc.Class IISTA SYSTEM CONROL N + P (ref. 00678)
A positive bias was confirmed to exists on the STA - Unicalibrator levels with STA - Deficient IX and STA - Deficient VIII when compared to the International Standard (IS) for factor VIII or IX. This bias is also observed on several External Quality Assessment (EQA) results.
- 2020-01-01FDA-DeviceDiagnostica Stago, Inc.Class IISTA UNICALIBRATOR (ref. 00675)
A positive bias was confirmed to exists on the STA - Unicalibrator levels with STA - Deficient IX and STA - Deficient VIII when compared to the International Standard (IS) for factor VIII or IX. This bias is also observed on several External Quality Assessment (EQA) results.
- 2020-01-01FDA-DeviceRAYSEARCH LABORATORIES ABClass IIRayStation stand-alone software treatment planning system, Model Numbers 4.0, 4.5, 4.7, 4.9, 5.0, 6.0, 6.1, 6.2, 6.3, 7.0, 8.0, 8.1, 9.0 - Product Usage: RayStation is a software system designed for treatment planning and analysis of radiation therapy. The treatment plans provide treatment unit set-up parameters and estimates of dose distributions expected during the proposed treatment, and may be used to administer treatments after review and approval by the intended user. The system functional
Editing a static arc beam may unexpectedly set the MU of the beam to its initial default value of 200 MU. If the bug is triggered, the dose is invalidated and needs to be recalculated before the plan can be approved or exported.
- 2020-01-01FDA-DeviceMedtronic Xomed, Inc.Class IILamicel 10PK 10MM INTL
Routine sterilization dose does not meet the required Sterility Assurance Level.
- 2020-01-01FDA-DeviceMedtronic Xomed, Inc.Class IILamicel 20PK 5MM INTL
Routine sterilization dose does not meet the required Sterility Assurance Level.
- 2020-01-01FDA-DeviceMedtronic Xomed, Inc.Class IILamicel 20PK 3MM INTL Cervical dilator
Routine sterilization dose does not meet the required Sterility Assurance Level.
- 2020-01-01FDA-DeviceAAP Implantate AgClass IIIINTEGRA, Drill CS 4.0, quick coupling single use, REF 430425
Products were distributed with the incorrect instructions for use.
- 2020-01-01FDA-DeviceAAP Implantate AgClass IIIINTEGRA, Drill CS 4.5, quick coupling single use, REF 430453
Products were distributed with the incorrect instructions for use.
- 2020-01-01FDA-DeviceCardinal Health Inc.Class IICordis S.M.A.R.T. CONTROL /S.M.A.R.T. Vascular Stent System. The S.M.A.R.T. CONTROL and S.M.A.R.T. Vascular Stent Systems consist of a self-expanding stent made of Nitinol (nickel-titanium alloy) material that is pre-mounted on an over-the-wire delivery system. The stents contain tantalum markers at each end. The S.M.A.R.T. CONTROL and S.M.A.R.T. Vascular Stents are designed to open to a preprogrammed diameter at body temperature. There are two delivery system configurations S.M.A.R
Cordis has initiated a labeling correction for S.M.A.R.T. and PRECISE stents due to incorrect MRI information on the IFU. The correct classification is "MRI Conditional" not "MRI Safe".
- 2020-01-01FDA-DeviceCardinal Health Inc.Class IICordis Precise Nitinol Stent System. The Cordis PRECISE Nitinol Stent System devices are designed to deliver a flexible, self-expanding endoluminal stent to the carotid vasculature via over-the-wire (OTW) 5.5F or 6F sheathed delivery systems. The stent is cut from a solid nitinol tube into a fine mesh ( Z configuration) design. The delivery systems consist mainly of an inner shaft and an outer sheath with radiopaque markers, and a Tuohy Borst valve. The inner shaft terminates distally in
Cordis has initiated a labeling correction for S.M.A.R.T. and PRECISE stents due to incorrect MRI information on the IFU. The correct classification is "MRI Conditional" not "MRI Safe".
- 2020-01-01FDA-DeviceCardinal Health Inc.Class IIS.M.A.R.T. Nitinol Stent System and the S.M.A.R.T. Control Nitinol Stent System. The SMART stent system includes a self-expanding stent made of Nitinol (nickel-titanium alloy) material and a 6 French (2.0 mm) or 7 French (2.3 mm) sheathed delivery system. The stent is laser cut from a solid nitinol tube into a fine mesh ( Z Configuration) design. The stent expands to its unconstrained diameter when released from the deployment catheter into the iliac artery. Upon deployment, the stent fo
Cordis has initiated a labeling correction for S.M.A.R.T. and PRECISE stents due to incorrect MRI information on the IFU. The correct classification is "MRI Conditional" not "MRI Safe".
- 2020-01-01FDA-DeviceGE Healthcare, LLCClass IICARESCAPE Central Station - Product Usage: The intended use is to provide clinicians with adult, pediatric and neonatal patient data within a hospital or clinical environment. The CARESCAPE Central Station is intended to collect information from a network and display this data. This data includes physiological, patient demographic and/or other nonmedical information.
When connected to the Mission Critical (MC) and /or Information Exchange (IX) networks, certain versions of the CARESCAPE Telemetry Server, ApexPro Telemetry Server, CARESCAPE Central Station (CSCS) version 1 and Central Information Center (CIC) systems were identified to have vulnerabilities to a cyber-attack.
- 2020-01-01FDA-DeviceGE Healthcare, LLCClass IICIC Pro Clinical Information Center Central Station - Product Usage: The intended use is to provide clinicians with adult, pediatric and neonatal patient data in a centralized location within a hospital or clinical environment. CIC Pro Clinical Information Center central station is intended to collect information from a network and display this data. This data includes physiological, patient demographic and/or other nonmedical information.
When connected to the Mission Critical (MC) and /or Information Exchange (IX) networks, certain versions of the CARESCAPE Telemetry Server, ApexPro Telemetry Server, CARESCAPE Central Station (CSCS) version 1 and Central Information Center (CIC) systems were identified to have vulnerabilities to a cyber-attack.
- 2020-01-01FDA-DeviceGE Healthcare, LLCClass IIApexPro Telemetry System - Product Usage: The ApexPro Telemetry System is intended for use under the direct supervision of a licensed healthcare practitioner. The system is designed to acquire and monitor physiological data for ambulating patients within a defined coverage area. The system processes this physiological data to detect various ECG arrhythmia events and select physiological parameter limit violations. The ApexPro Telemetry System is intended to be installed in the hospital or clinic
When connected to the Mission Critical (MC) and /or Information Exchange (IX) networks, certain versions of the CARESCAPE Telemetry Server, ApexPro Telemetry Server, CARESCAPE Central Station (CSCS) version 1 and Central Information Center (CIC) systems were identified to have vulnerabilities to a cyber-attack.
- 2020-01-01FDA-DeviceBard Peripheral Vascular IncClass IIBARD MAX-CORE Disposable Core Biopsy Instrument - Product Usage: The core needle biopsy device is intended for use in obtaining biopsies from soft tissues such as liver, kidney, prostate, spleen, lymph nodes and various soft tissue tumors. It is not intended for use in bone.
During the firm's review of May 2019 complaint data, a significant increase in Disposable Core Biopsy Instrument complaints were observed for Failure to Fire, Firing Problem, and Failure to Obtain Samples.
- 2020-01-01FDA-DeviceLIFELINES NEURO COMPANYClass IIElectroTek Temporal Sensor Cable Gold - Long Length, Single Length - Product Usage: The electroencephalographic system ElectroTek is intended to acquire, display, and store the electrical activity of a patient s brain obtained by placing electrodes on the patient s scalp. The ElectroTek is intended to be used for such studies as electroencephalogram (EEG) and video EEG recording to aid in diagnosis. The ElectroTek does not draw any diagnostic conclusions.
Potential for one of the four temporal electrode cables used in with the ElectroTek EEG system having incorrect placement labels which could lead to incorrect placement of electrode for an EEG study.