- 2018-09-26FDA-DeviceArrow International IncClass IIARROW¿ Bipolar Electrode Catheter with shrouded pins , 6 Fr, 110 cm Product Code: AI-06210-S Product Usage: Arrow electrophysiology catheters are intended for temporary use in electrophysiology studies for intracardiac stimulation and/or ECG recording
Products are labeled with an incorrect expiration date
- 2018-09-26FDA-DeviceSmiths Medical ASD Inc.Class IIIPortex Pulsator Arterial Blood Sampling Kit with Dry Lithium Heparin for Gases and Electrolytes, REF 4080P-2, Sterile, RX. The firm name on the label is Smiths Medical ASD, Inc., Keene, NH.
The product was mislabeled with the incorrect label.
- 2018-09-26FDA-DeviceFresenius Medical Care Renal Therapies Group, LLCClass II2008T HEMODIALYSIS SYSTEM W/BIBAG, Part Number 190766, Applicable only with 2008T BlueStar Premium Upgrade Kit, Part Number 191138 Product Usage: Indicated for acute and chronic dialysis therapy.
In the hemodialysis machine during the cleaning/disinfection program, when there is a power failure or interruption, the dialysis program button should be greyed out when the machine is powered up and a mandatory rinse should be required. However, if a power failure or interruption occurs during the cleaning/disinfection program with the auto-start feature enabled, the machine enters the dialysis program even though the dialysis program button is disabled and the mandatory rinse has not been performed. As a result, disinfecting chemical may not be completely removed from the machine before starting a treatment and disinfectant could exist in the dialysate delivered to the patient.
- 2018-09-26FDA-DeviceFresenius Medical Care Renal Therapies Group, LLCClass II2008T HEMODIALYSIS SYS, WITH CDX, Part Number 190713, Applicable only with 2008T BlueStar Premium Upgrade Kit, Part Number 191138 Product Usage: Indicated for acute and chronic dialysis therapy.
In the hemodialysis machine during the cleaning/disinfection program, when there is a power failure or interruption, the dialysis program button should be greyed out when the machine is powered up and a mandatory rinse should be required. However, if a power failure or interruption occurs during the cleaning/disinfection program with the auto-start feature enabled, the machine enters the dialysis program even though the dialysis program button is disabled and the mandatory rinse has not been performed. As a result, disinfecting chemical may not be completely removed from the machine before starting a treatment and disinfectant could exist in the dialysate delivered to the patient.
- 2018-09-26FDA-DeviceOrtho-Clinical DiagnosticsClass IIIVITROS Chemistry Products CREA Slides, Product Code 680 2584 Product Usage: VITROS CREA Slides (Product Code 680 2584) - For in vitro diagnostic use only. VITROS Chemistry Products CREA Slides quantitatively measure creatinine (CREA) concentration in serum, plasma, and urine using VITROS 250/350/950/5,1 FS and 4600 Chemistry Systems and the VITROS 5600 Integrated System.
The slides did not meet the current claims for Limit of Blank (LoB), Limit of Detection (LoD) and Limit of Quantification (LoQ) for serum and urine samples and therefore affecting the low end of the measuring range for this assay. The current low end measuring range is 0.05mg/dL for serum and 1.2mg/dL for urine. Based on the CREA testing results for the LoQ, the revised low end CREA measuring range is 0.15mg/dL for serum and 3.2mg/dL for urine.
- 2018-09-26FDA-DeviceInvivo CorporationClass IIXper Flex Cardio Physiomonitoring System Model # 453564669081 Software Version 1.6.0.0388
Released with an incorrect, older firmware version installed. May result in intermittent loss of ECG monitoring, inaccurate ECG amplitude display and or auxiliary output, and inaccurate heart rate (HR) displayed due to QRS detection fault.
- 2018-09-26FDA-DeviceSwissray MedicalClass IIddR Formula B X-ray System, Model ddR Formula B X-ray system used for imaging
Potential for bucky (the part that holds the grid and is moveable to position the patient) moving unexpectedly.
- 2018-09-26FDA-DeviceSiemens Medical Solutions USA, IncClass IIARTIS Pheno Interventional Fluoroscopic X-Ray System, Model Number 10849000
Temperature of the detector may fall out of its designed working range (cool down) due to incorrectly configured temperature control unit. This unintentional system behavior may occur while the unit is powered down for long periods (e.g. at night).
- 2018-09-26FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis Q Interventional Fluoroscopic X-Ray System, Model Numbers 10848280, 10848281, 10848282, 10848283, 10848354 & 10848355
Temperature of the detector may fall out of its designed working range (cool down) due to incorrectly configured temperature control unit. This unintentional system behavior may occur while the unit is powered down for long periods (e.g. at night).
- 2018-09-26FDA-DeviceEOS ImagingClass IIsterEOS workstation
3D projections may be incorrect when the pair of images used is a secondary capture generated from a series containing more than two images, where one of the images has been manually flipped. Projection errors may lead to errors in calculation of 3D clinical parameters when adjusting the position, size and shape of the 3D objects used. Incorrect clinical parameters can be a contributing factor in incorrect clinical decisions, or sub-optimal surgical interventions.
- 2018-09-26FDA-DeviceTecan US, Inc.Class IIFreedom EV0-2 with any version of EVOware and EVOware Sample Tracking Add-On V1.0 or higher
There is a software issue that can potentially impact sample identification and traceability under specific conditions when using EVOware Add On Software: Sample Tracking -Multi Instrument V1.0 or higher, Part Number 30019971.
- 2018-09-26FDA-DevicePolymedco, Inc.,/Polymedco Cancer Diagnostic Products, LlcClass IIPATHFAST NTproBNP Catalog Number: PF1061-KUS PATHFAST¿ NTproBNP is a product for in-vitro diagnostic use with the in vitro diagnostic system PATHFAST¿ for the quantitative measurement of N-terminal-pro B-type Natriuretic Peptide (NT-proBNP) in heparinized or EDTA whole blood and plasma.
A pinhole caused by the laser printer in the aluminum sheet over the ALP reagent wells caused leakage through the pinhole. If the cartridge with leakage is used, higher measurement value as low as +12% and no higher than +20% bias may be obtained.
- 2018-09-26FDA-DevicePolymedco, Inc.,/Polymedco Cancer Diagnostic Products, LlcClass IIPATHFAST Myoglobin II reagent cartridge Catalog Number: PF1111-K PATHFAST¿ NTproBNP is a product for in-vitro diagnostic use with the in vitro diagnostic system PATHFAST¿ for the quantitative measurement of N-terminal-pro B-type Natriuretic Peptide (NT-proBNP) in heparinized or EDTA whole blood and plasma.
A pinhole caused by the laser printer in the aluminum sheet over the ALP reagent wells caused leakage through the pinhole. If the cartridge with leakage is used, higher measurement value as low as +12% and no higher than +20% bias may be obtained.
- 2018-09-26FDA-DeviceOrtho-Clinical DiagnosticsClass IIIVITROS Chemistry Products Cl- Slides, Product Code 684 4471 Product Usage: VITROS Cl Slides (Product Code 684 4471) - For in vitro diagnostic use only. VITROS Chemistry Products Cl- Slides quantitatively measure chloride (Cl-) concentration in serum, plasma and urine using VITROS 250/350/5,1 FS and 4600 Chemistry Systems and the VITROS 5600 Integrated System. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabe
The slides failed to meet current claims for Limit of Blank (LoB), Limit of Detection (LoD) and Limit of Quantification (LoQ) for urine samples. The measuring range (15-300 mmol/L) for urine samples when tested with the Cl- slide is not affected. The current Cl- LoQ is 5 mmol/L and the LoQ determined by this investigation is 15 mmol/L.
- 2018-09-26FDA-DeviceMed-Mizer, Inc.Class IIPR1000 Pivot Rehab Bed AC powered adjustable bed.
Under certain conditions, when pivoting bed to the extreme left there are situations where the wire/cables may become pinched. A failure would result in the resident requiring to be transferred to a different bed until repairs can be made
- 2018-09-26FDA-DeviceMako Surgical CorporationClass IIMakoplasty RIO Standard System; Ethernet to Fiber Optic Converter Catalog # 200933 Product Usage: The Partial Knee Application (PKA), for use with the Mako System, is indicated for use in surgical knee procedures, in which the use of stereotactic surgery may be appropriate, and where reference to rigid anatomical bony structures can be identified relative to a CT based model of the anatomy. These procedures include Unicondylar knee replacement and/or patellofemoral knee replacement.
Communication-connection error.
- 2018-09-26FDA-DeviceStryker Medical Division of Stryker CorporationClass IIIsoFlex LAL Support Surface, Model Number 2860 Product Usage: : The IsoFlex LAL support surface assists in the prevention and treatment of all pressure injuries (including stages 1,2,3,4, unstageable injury, and deep tissue injury) and is recommended to be implemented in combination with clinical evaluation of risk factors and skin assessments made by a health care professional. This support surface is for use with human patients with existing or at risk of incurring pressure injuries. Th
Certain 2860 IsoFlex LAL support surfaces were assembled with a non-conforming fire barrier.
- 2018-09-26FDA-DevicebioMerieux, Inc.Class IIVITEK(R) 2 AST-P655, For susceptibility testing of Staphylococcus spp. Enterococcus spp., ad S agalactiae against specified antimicrobials, REF 421913 Product Usage: VITEK¿ 2 is an automated system consisting of instruments, software and reagent cards designed for the identification and antimicrobial susceptibility testing of bacteria and yeast. The VITEK¿ 2 utilizes growth-based biochemical patterns to determine identification. The VITEK¿ 2 provides minimal inhibitory concentration (MIC) r
Routine internal review of Device History Records identified six VITEK(R) 2 AST card lots were manufactured with less drug (gentamicin) than required for the Gentamicin High-Level Resistance (ghlr01n) screen test due to an error when making 1500mL and 2000mL media well preparations (solutions).
- 2018-09-26FDA-DevicebioMerieux, Inc.Class IIVITEK(R) 2 AST-P640, For susceptibility testing of Staphylococcus spp. Enterococcus spp., ad S agalactiae against specified antimicrobials, REF 418579 Product Usage: VITEK¿ 2 is an automated system consisting of instruments, software and reagent cards designed for the identification and antimicrobial susceptibility testing of bacteria and yeast. The VITEK¿ 2 utilizes growth-based biochemical patterns to determine identification. The VITEK¿ 2 provides minimal inhibitory concentration (MIC) r
Routine internal review of Device History Records identified six VITEK(R) 2 AST card lots were manufactured with less drug (gentamicin) than required for the Gentamicin High-Level Resistance (ghlr01n) screen test due to an error when making 1500mL and 2000mL media well preparations (solutions).
- 2018-09-26FDA-DevicePermobil, AbClass IIPermobil powered wheelchairs, Model Numbers: (a) M300 PS, (b) C300 PS, (c) C350 PS, (d) C500 PS, (e) C400 PS Product Usage: The devices identified are intended to provide outdoor and indoor mobility to persons limited to a seated position that can operate a powered wheelchair.
This correction decision has been made because of a potential failure of one or both backrest bars providing back support. If one or both back support telescoping bars fail the user could fall back leading to a potential injury.
- 2018-09-26FDA-DeviceZimmer Biomet, Inc.Class IIGentle Thread PLGA Full Thread Interference Screw, 10x30mm, Item Number 905629
The Gentle Thread PLGA Round Head, 7x20mm and the Gentle Thread PLGA Full Thread 10x30 have been commingled.
- 2018-09-26FDA-DeviceZimmer Biomet, Inc.Class IIGentle Thread PLGA Round Head Interference Screw, 7x20mm, Item Number 905612
The Gentle Thread PLGA Round Head, 7x20mm and the Gentle Thread PLGA Full Thread 10x30 have been commingled.
- 2018-09-26FDA-DeviceLeica Microsystems, Inc.Class IILeica M525 F20 Surgical Microscope System
The firm received complaints that the instrument tipped over when the swing arm was fully extended.
- 2018-09-26FDA-DeviceVentana Medical Systems IncClass IultraView SISH DNP Detection Kit, Catalog Number 05907136001, model 800-098 Immunohistochemistry (IHC) for in vitro diagnostic use.
Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur.
- 2018-09-26FDA-DeviceVentana Medical Systems IncClass INEXES VEN IVIEW DAB DET KT JPN-US EXPORT, Catalog Number 05266084001 Model 760-041 Immunohistochemistry (IHC) for in vitro diagnostic use.
Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur.
- 2018-09-26FDA-DeviceVentana Medical Systems IncClass IINFORM HPV III Fam 16 Probe - US Export, Catalog Number 05278856001, model 800-4295 Immunohistochemistry (IHC) for in vitro diagnostic use.
Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur.
- 2018-09-26FDA-DeviceVentana Medical Systems IncClass ICINtec p16 Histology (250) CE, Catalog Number 06695256001, model 825-4713 Immunohistochemistry (IHC) for in vitro diagnostic use.
Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur.
- 2018-09-26FDA-DeviceVentana Medical Systems IncClass ICINtec p16 Histology (250), Catalog Number 06695230001, Model 725-4713 Immunohistochemistry (IHC) for in vitro diagnostic use.
Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur.
- 2018-09-26FDA-DeviceVentana Medical Systems IncClass ICINtec Histology (250), Catalog Number 06680011001, model 725-4793 Immunohistochemistry (IHC) for in vitro diagnostic use.
Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur.
- 2018-09-26FDA-DeviceVentana Medical Systems IncClass IVENTANA anti-Helicobacter Pylori (SP48) PAB 250, Catalog Number 06425623001, model 790-1015 Immunohistochemistry (IHC) for in vitro diagnostic use.
Leaking and sticking reagent dispensers for horseradish peroxidase (HRP) dispensers. A false negative IHC result may occur.