Medical device recalls
39229 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2017-09-06FDA-DeviceVyaire MedicalClass IIAirLife(TM) Reduced Heparin ARTERIAL BLOOD SAMPLER, REF 9025RHTR, 1ML SYRINE 25G 5/8", LUER SLIP PROTECTIVE SHEATH, 3.2 IU, STERILE R, Rx ONLY, CAREFUSION Lot #0001047501 of the 9025RHTR ABG sampling kits have been manufactured containing the incorrect sub-assembly which includes a larger needle (23 Gage, 1" needle), larger syringe (3mL), and larger amount of heparin (113IU), than what is intended for the kit.
Lot #0001047501 of the 9025RHTR ABG sampling kits have been manufactured containing the incorrect sub-assembly which includes a larger needle (23 Gage, 1" needle), larger syringe (3mL), and larger amount of heparin (113IU), than what is intended for the kit.
- 2017-09-06FDA-DeviceMaster & Frank (Pinghu) Co., Ltd.Class IIMEDLINE SIRUS Surgical Gown, Strong Protection, Poly-Reinforced, Breathable Film Sleeve, XXL-XLONG Sterile Single-Use Gown; Sold in kit with Sterile Gown/Hand Towel/CSR Wrap and boxes of 18 Gowns.
The sleeve seam of the breathable material was found to have inconsistent sealing, which has the potential to allow fluid to flow pass through the protective seam.
- 2017-09-06FDA-DeviceCertified Safety Mfg IncClass IIBurn Sheet, sterile - 60" x 96". Included in First Aid Kits: 36M - Delmarva Power/ACE - w/Logo, Certified Safety Manufacturing logo, and sold blank. product Usage: Provides sterile environment to protect patient from infection
Burn Sheet has possibility of being shredded.
- 2017-09-06FDA-DeviceEdwards Lifesciences, LLCClass IIFogarty Adherent Clot Catheter Model Numbers 1408010 and 140806 Product Usage: The Fogarty adherent clot catheters are designed to effectively remove clot material in the peripheral vasculature. The catheters are indicated for the removal of emboli and thrombi from native arteries or synthetic grafts. The device are designed to facilitate clots too resistant to be removed by an elastomeric balloon. The device features a spiral-shaped, latex-covered stainless steel cable that assumes a corksc
The diameter of the Fogarty Catheter balloon, measures 6mm instead of 10mm.
- 2017-09-06FDA-DeviceBiomerieux IncClass IIVITEK¿ 2 Compact 30, REF numbers: 27530 and 27530R (clinical), and 27630 and 17630R (industry) software and reagent cards designed for the identification (ID) and antimicrobial susceptibility testing (AST) of bacteria and yeast.
Customers have reported that some VITEK¿ 2 cards are staying in preliminary status, not finalizing after ejection from the instrument, and not allowing cards in subsequent carousel slots to be processed. The issue was reported to occur on VITEK¿ 2 Compact 15 and Compact 30 systems following a system software update to version 8.01.
- 2017-09-06FDA-DeviceBiomerieux IncClass IIVITEK¿ 2 Compact 15, REF numbers: 27415 and 27415R software and reagent cards designed for the identification (ID) and antimicrobial susceptibility testing (AST) of bacteria and yeast.
Customers have reported that some VITEK¿ 2 cards are staying in preliminary status, not finalizing after ejection from the instrument, and not allowing cards in subsequent carousel slots to be processed. The issue was reported to occur on VITEK¿ 2 Compact 15 and Compact 30 systems following a system software update to version 8.01.
- 2017-09-06FDA-DeviceKentec Medical IncClass IIPOLYURETHANE ENFit(R) AMERITUS NG FEEDING TUBE, WITH SIDE PORT, REF Numbers: a) ENF-Y50P-40 b) ENF-Y50P-50 c) ENF-Y60P-40 d) ENF-Y60P-50 e) ENF-Y60P-90 f) ENF-Y80P-40 g) ENF-Y80P-50 h) ENF-Y80P-80 i) ENF-Y80P-90 For pediatric and Neonatal Use, ENFit ENTERAL USE ONLY, RADIOPAQUE STRIPE, STERILE, EO, SINGLE USE ONLY, QTY 10/BOX.
Inadequate detectability of radiopaque stripes
- 2017-09-06FDA-DeviceKentec Medical IncClass IIPOLYURETHANE ENFit(R) AMERITUS NG FEEDING TUBE, REF Numbers: a) ENF-50P-40 b) ENF-50P-50 c) ENF-50P-80 d) ENF-60P-40 e) ENF-60P-50 f) ENF-60P-80 g) ENF-80P-40 h) ENF-80P-50 i) ENF-80P-80 j) ENF-100P-110 For pediatric and Neonatal Use, ENFit ENTERAL USE ONLY, RADIOPAQUE STRIPE, STERILE, EO, SINGLE USE ONLY, QTY 10/BOX.
Inadequate detectability of radiopaque stripes
- 2017-09-06FDA-DeviceMedspira, LlcClass IImcompass 2-channel Balloon Catheters The mcompass Biofeedback Anorectal Manometry System is for use on patients requiring anorectal pressure studies. mcompass Anorectal Manometry System (RMD-001-001) which includes a FOB component connected to the balloon catheter to inflate and deflate and a medical grade tablet PC to run the software. The software is not included in the recall, only the balloon catheter component.
Potential failure in the balloon bond in the inner catheter stem, leading to the separation of the balloon from the inner stem, leaving it in the rectal cavity.
- 2017-09-06FDA-DeviceSmiths Medical ASD Inc.Class IICADD(R) Medication Cassette Reservoir with clamp and female Luer. Non vented stopper included, REF 21-7002-24, Rx only, STERILE EO, Manufacturer Smiths Medical ASD, Inc.
The medication cassette reservoir, part number 21-7002-24, with lot number 16X659, may have been manufactured with the incorrect pressure plate and the tubing used on the cassette may have been routed incorrectly.
- 2017-09-06FDA-DeviceToshiba American Medical Systems IncClass IIToshiba America Medical Systems Ultimax Digital Fluoroscopic X-Ray System Model: DREX-UI80 Ultimax is intended for gastrointestinal studies, vascular studies, general radiography, and fluoroscopy. The system has medical applications ranging from but not limited to: contrast-enhanced studies, support of endoscopic studies, nonvascular contrast-enhanced studies, nonvascular IVR, vascular contrast-enhanced studies support of vascular NR, and general radiography.
The issue was identified as a firmware problem with the generator.
- 2017-09-06FDA-DeviceNeusoft Medical Systems Co., Ltd.Class IINeusoft NeuViz 128 Multi-slice CT Scanner System Product Usage: The Multi-Slice CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and detector array. The acquired X-RAY transmission data is reconstructed by computer into cross-sectional images of the body from either the same axial plane taken at different angles or spiral planes taken at different angles.
Software defect
- 2017-09-06FDA-DeviceNeusoft Medical Systems Co., Ltd.Class IINeusoft Medical NeuViz 64 Multi-slice CT Scanner System, including: NeuViz 64e, NeuViz 64i with software version 1.0.6.3258 +P11 or previous version, NeuViz 64En, NeuViz 641n with software version 1.0.7.4021+P11 or previous version Product Usage: The Multi-Slice CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and detector array. The acquired X-RAY transmission data is reconstructed by computer into cross-secti
Software defect
- 2017-09-06FDA-DeviceNeuroLogica CorporationClass IISamsung GU60A system- Digital X-ray Imaging Systems are intended for use in generating radiographic images of human anatomy by a qualified/trained doctor or technician. This device is not intended for mammographic applications
When performing the Stitching function on GU60A system, unintended area is exposed to radiation
- 2017-09-06FDA-DeviceOptovue, Inc.Class IIiVue 500 with iScan, D216606. Product non-contact, high resolution tomographic imaging device. It is intended for in vivo imaging, axial cross-sectional and three-dimensional imaging and measurement of anterior and posterior ocular structures, including retina, retinal nerve fiber layer, ganglion cell complex (GCC), optic disc, cornea, and anterior chamber of the eye. The iVue 500 with normative database is a quantitative tool for the comparison of retina, retinal nerve fiber layer, ganglion
FDA determined that a 510(k) is needed for the Vault Mapping software (also known as Lens Fitting).
- 2017-09-06FDA-DeviceOptovue, Inc.Class IIiFusion, Device Listing Number D203271. Product Usage: The iCam is a non-contact, high resolution digital imaging device which is suitable for photographing, displaying and storing images of the retina and external areas of the eye to be evaluated under non-mydriatic conditions. The iCam takes digital images of the posterior and external structures of the eye without the use of a mydriatic agent and is intended for use as an aid to clinicians in the evaluation, diagnosis and documentation o
FDA determined that a 510(k) is needed for the Vault Mapping software (also known as Lens Fitting).
- 2017-09-06FDA-DeviceOptovue, Inc.Class IIiVue with Normative Database, Device Listing Number D185549. Product Usage: The iVue (K121739) is a non-contact, high resolution tomographic imaging device. It is intended for in vivo imaging, axial cross-sectional, and three dimensional imaging and measurement of anterior and posterior ocular structures, including retina, retinal nerve fiber layer, ganglion cell complex (GCC), optic disc, cornea, and anterior chamber of the eye. The iVue with Normative Database is a quantitative tool for t
FDA determined that a 510(k) is needed for the Vault Mapping software (also known as Lens Fitting).
- 2017-08-30FDA-DeviceMedtronic NeuromodulationClass IIDBS Lead Depth Stop contained in Medtronic Deep Brain Stimulation (DBS) lead kits, models 3387/3387S, 3389/3389S, and 3391/3391S, The lead kit contains one DBS lead in addition to multiple accessories used in DBS lead implant procedures. Among these accessories is the DBS lead holder, also referred to as the lead depth stop. The lead holder affixes to the DBS lead during the lead implant procedure, marking the distance to the lead tip and providing control of DBS lead depth during implant b
Medtronic received reports that the DBS depth stop did not adequately secure to the lead, which can result in DBS lead placement beyond the intended target.
- 2017-08-30FDA-DevicePentax of America IncClass IIUltrasound Video Gastroscope, Model EG-3870UTK. The product is intended to be used in combination with the ultrasound scanning unit made by Hitachi Medical Corporation, and the PENTAX Medical video processor to provide images for observation, diagnosis, imaging, or therapy of the upper gastrointestinal tract from esophagus through duodenum.
Error in reprocessing instructions in Revisions 13 and 14 of IFU Z845, used with EG-3670URK and EG-3870UTK ultrasound gastroscopes. In the disinfection step, the IFU has a warning indicating the cleaning detergent solution should remain in contact with the all internal channels and external endoscope surfaces. The disinfecting solution, not the cleaning detergent, should be used for this step.
- 2017-08-30FDA-DevicePentax of America IncClass IIUltrasound Video Gastroscope, Model EG-3670URK, The product is intended to be used in combination with the ultrasound scanning unit made by Hitachi Medical Corporation, and the PENTAX Medical video processor to provide images for observation, diagnosis, imaging, or therapy of the upper gastrointestinal tract from esophagus through duodenum.
Error in reprocessing instructions in Revisions 13 and 14 of IFU Z845, used with EG-3670URK and EG-3870UTK ultrasound gastroscopes. In the disinfection step, the IFU has a warning indicating the cleaning detergent solution should remain in contact with the all internal channels and external endoscope surfaces. The disinfecting solution, not the cleaning detergent, should be used for this step.
- 2017-08-30FDA-DeviceShippert Medical TechnologiesClass IITissu-Trans SFILL 360, 3-TT-SFILL 360. Product Usage: Intended for fat transfer and liposuction.
Seal integrity of the Tissu-Trans product sterile packages cannot be assured.
- 2017-08-30FDA-DeviceShippert Medical TechnologiesClass IITissu-Trans MEGA 1500, 3-TT-MEGA 1500. Product Usage: Intended for fat transfer and liposuction.
Seal integrity of the Tissu-Trans product sterile packages cannot be assured.
- 2017-08-30FDA-DeviceShippert Medical TechnologiesClass IITissu-Trans Filtron 2000, 3-TT-FILTRON 2000. Product Usage: Intended for fat transfer and liposuction.
Seal integrity of the Tissu-Trans product sterile packages cannot be assured.
- 2017-08-30FDA-DeviceShippert Medical TechnologiesClass IITissu-Trans Filtron 1000, 3-TT-FILTRON 1000. Product Usage: Intended for fat transfer and liposuction.
Seal integrity of the Tissu-Trans product sterile packages cannot be assured.
- 2017-08-30FDA-DeviceShippert Medical TechnologiesClass IITissu-Trans Filtron 500, 3-TT-FILTRON 500. Product Usage: Intended for fat transfer and liposuction.
Seal integrity of the Tissu-Trans product sterile packages cannot be assured.
- 2017-08-30FDA-DeviceShippert Medical TechnologiesClass IITissu-Trans Filtron 250, 3-TT-FILTRON 250. Product Usage: Intended for fat transfer and liposuction.
Seal integrity of the Tissu-Trans product sterile packages cannot be assured.
- 2017-08-30FDA-DeviceShippert Medical TechnologiesClass IITissu-Trans Filtron 100, 3-TT-FILTRON 100. Product Usage: Intended for fat transfer and liposuction.
Seal integrity of the Tissu-Trans product sterile packages cannot be assured.
- 2017-08-30FDA-DeviceCustom Assemblies IncClass IIVarious custom surgical kits manufactured for CMS, CUSTOM MEDICAL SPECIALTIES, INC.: (a) CMS-4153-R2 MPM Biopsy TRAY (b) CMS-5832-R1 Custom Safety Mammo Biopsy Tray (c) CMS-4108 Multipurpose Safety Tray (d) CMS-3141-R6 Custom Ultrasound Tray (e) CMS-2891-R1 Custom Safety Biopsy Tray (f) CMS-5798-R1 Custom Safety Biopsy Tray (g) CMS-2357R2 Custom Biopsy Tray (h) CMS-2540-R4 Custom Biopsy Tray
The firm manufactured and distributed custom surgical kits which contained BD SafetyGlide" 22GA 1¿ inch Needles. BD subsequently recalled these needles because, " Loose polypropylene particulate in the fluid path could be expelled out of the needle during injection.
- 2017-08-30FDA-DeviceMedtronic Navigation, Inc.Class IIMedtronic ENT Prgm 9734636 Add Fusion Nav AxiEM, reusable, Rx. This kit includes 9733908 (which includes 9733452 containing 9733449, Straight Suction, 9733450, 70 deg Curved Suction, and 9733451, 90 deg Curved Suction). The firm name on the label is Medtronic Navigation, Inc., Louisville, CO. The suction devices are part of a family of reusable ENT instruments that are used with the StealthStationTM AxiEM surgical navigation system. The AxiEM system is an electromagnetic (EM) tracking solutio
The instruments are not able to pass instrument verification which is performed prior to the use of each instrument.
- 2017-08-30FDA-DeviceMedtronic Navigation, Inc.Class IIMedtronic Set Supplemental INS AxiEM ENT, Ref. 9734378, reusable, RX. This kit contains 9734308, Small Straight suction. The firm name on the label is Medtronic Navigation, Inc., Louisville, CO. The suction devices are part of a family of reusable ENT instruments that are used with the StealthStationTM AxiEM surgical navigation system. The AxiEM system is an electromagnetic (EM) tracking solution for surgical tools. The system measures an induced voltage created by local magnetic fields from
The instruments are not able to pass instrument verification which is performed prior to the use of each instrument.