- 2025-01-22FDA-DeviceKarl Storz EndoscopyClass IIKarl Storz - Endoskope - REF 723400 - Optical Biopsy and Grasping Forceps, CE
Due to failure of manual cleaning validation, biopsy and grasping forceps like sterility assurance.
- 2025-01-22FDA-DeviceBiocartis NvClass IIIdylla INSTRUMENT, IVD, REF P0010. Intended for the detection of nucleic acid targets in various types of human samples, using disposable Test-specific ldylla Cartridges.
False-positive MSI-H results generated by the Idylla MSI Test.
- 2025-01-22FDA-DeviceAlcon Research LLCClass IIBrand Name: Alcon Product Name: Monarch¿ III D Delivery Cartridge Model/Catalog Number: 8065977763 Product Description: Monarch¿ III D delivery cartridge Lens Guide, Intraocular Component: N/A
Increase in complaints associated with a molding defect within the inner lumen of delivery cartridges which could result in a scratch on the intraocular lens (IOL) upon delivery.
- 2025-01-22FDA-DeviceCook Biotech, Inc.Class IICook Medical Biodesign Dural Graft, REF C-DUR-7X10, REF G31091, Sterile
Incorrect version of IFU was used rather than updated version; and incorrect expiration date was used on two of the products.
- 2025-01-22FDA-DeviceCook Biotech, Inc.Class IICook Medical Biodesign Hiatal Hernia Graft, REF C-PHR-7X10-U, REF G31455, Sterile; and
Incorrect version of IFU was used rather than updated version; and incorrect expiration date was used on two of the products.
- 2025-01-22FDA-DeviceCook Biotech, Inc.Class IICook Medical Biodesign Otologic Butterfly Graft, REF ENT-OTO-BFLY-0.4-0.6, REF G60285, Sterile.
Incorrect version of IFU was used rather than updated version; and incorrect expiration date was used on two of the products.
- 2025-01-22FDA-DeviceNuwellis IncClass Inuwellis AquaFlexFlow UF 500 Plus, REF 114156, Catalog Number A06163, extracorporeal blood circuit which is used with the Aquadex SmartFlow or Aquadex FlexFlow System
The AquaFlexFlow UF 500 Plus extracorporeal blood circuit used with the Aquadex SmartFlow and FlexFlow Systems may indicate "Ultrafiltrate Weight Mismatch" or Excessive Weight Mismatch Alarms while in use. If not addressed, this failure could result in excess fluid removal from a patient leading to Acute Volume Depletion. This failure is especially serious when the Aquadex System is being used on pediatric patients.
- 2025-01-22FDA-DeviceAbiomed, Inc.Class IImpella RP Flex with SmartAssist; Product Number: 1000323;
Optical Sensors have been damaged due to physical interaction between the inlet and another device resulting in a Placement Signal Not Reliable (PSNR) alarm and loss of Central Venous (CV) Placement Signal, Pulmonary Artery (PA) Placement Signal & Pulmonary Artery Pulse Index (PAPi) metrics. Abiomed is reinforcing that there is a risk of potential interaction between the tip of guidewires, indwelling central venous lines or devices and inlet of the Impella pumps listed above during the insertion, manipulation, and removal of those devices. The interaction may result in optical sensor damage, temporary pump stop, or permanent pump stop.
- 2025-01-22FDA-DeviceAbiomed, Inc.Class IImpella RP with SmartAssist; Product Number: 0046-0035;
Optical Sensors have been damaged due to physical interaction between the inlet and another device resulting in a Placement Signal Not Reliable (PSNR) alarm and loss of Central Venous (CV) Placement Signal, Pulmonary Artery (PA) Placement Signal & Pulmonary Artery Pulse Index (PAPi) metrics. Abiomed is reinforcing that there is a risk of potential interaction between the tip of guidewires, indwelling central venous lines or devices and inlet of the Impella pumps listed above during the insertion, manipulation, and removal of those devices. The interaction may result in optical sensor damage, temporary pump stop, or permanent pump stop.
- 2025-01-22FDA-DeviceBoston Scientific CorporationClass IVISIONIST CRT-P, EL (Model Number U225 and U226) and EL MRI (Model Number U228)
A subset of devices from the ACCOLADE Family of Pacemakers and CRT-Ps, built before September 2018, have an increased potential to initiate Safety Mode during telemetry or other normal, higher-power operations due to latent high battery impedance.
- 2025-01-22FDA-DeviceBoston Scientific CorporationClass IVALITUDE CRT-P, EL (Model Number U125) and EL MRI (Model Number U128)
A subset of devices from the ACCOLADE Family of Pacemakers and CRT-Ps, built before September 2018, have an increased potential to initiate Safety Mode during telemetry or other normal, higher-power operations due to latent high battery impedance.
- 2025-01-22FDA-DeviceBoston Scientific CorporationClass IALTRUA 2 DR Pacemaker, SL (Model Number S702) and EL (Model Number S722)
A subset of devices from the ACCOLADE Family of Pacemakers and CRT-Ps, built before September 2018, have an increased potential to initiate Safety Mode during telemetry or other normal, higher-power operations due to latent high battery impedance.
- 2025-01-22FDA-DeviceBoston Scientific CorporationClass IESSENTIO DR Pacemaker, SL (Model Number L101, SL MRI (Model Number L111), EL (Model Number L121), and EL MRI (Model Number L131)
A subset of devices from the ACCOLADE Family of Pacemakers and CRT-Ps, built before September 2018, have an increased potential to initiate Safety Mode during telemetry or other normal, higher-power operations due to latent high battery impedance.
- 2025-01-22FDA-DeviceBoston Scientific CorporationClass IPROPONENT DR Pacemaker, SL (Model Number L201), (VDD) SL (Model Number L209), SL MRI (Model Number L211), EL (Model Number L221), and EL MRI (Model Number L231).
A subset of devices from the ACCOLADE Family of Pacemakers and CRT-Ps, built before September 2018, have an increased potential to initiate Safety Mode during telemetry or other normal, higher-power operations due to latent high battery impedance.
- 2025-01-22FDA-DeviceBoston Scientific CorporationClass IACCOLADE DR Pacemaker, SL (Model Number L301), SL MRI (Model Number L311), EL (Model Number L321), and EL MRI (Model Number L331)
A subset of devices from the ACCOLADE Family of Pacemakers and CRT-Ps, built before September 2018, have an increased potential to initiate Safety Mode during telemetry or other normal, higher-power operations due to latent high battery impedance.
- 2025-01-22FDA-DeviceMercury Enterprises, Inc. dba Mercury MedicalClass INeo-Tee T-Piece Resuscitator, for pediatric emergency respiratory support, Part: 1050805, 1050808, 1050809, 1050810, 1050811, 1050814, 1050832, 1050839, 1050840, 1050841, 1050842
Gas powered emergency resuscitator has a circuit flow controller manufactured with an undersized spring, which may cause resuscitator not reach the high and low ends of the PIP and PEEP pressure ranges, which may cause a loss of positive pressure, impacting effective ventilation of the patient.
- 2025-01-22FDA-DeviceMEDLINE INDUSTRIES, LP - NorthfieldClass IMedline Fluid Delivery Set with Drip Chamber: 1) MTO,135,YELLOW,MICRO,SPK-MAIMONIDES, Item Number: 60130527; 2) MTO,ANGIO,DOUBLE,SPIKE,KIT,KENNEDY HLTH, Item Number: 65111341; 3) MTO,ANGIO,SINGLE,SPIKE,KIT, Item Number: 65232486; 4) MTO,ANGIO,SINGLE,SPIKE,KIT,GOOD,SAM, Item Number: 65071193; 5) MTO,NEURO,FLUSH,SPIKE,KIT,BLUE,FLORIDA, Item Number: 600604422; 6) MTO,NEURO,KIT,-,JERSEY,SHORE PG, Item Number: 60100045; 7) MTO,RADIOLOGY,KIT,HAMOT MED CEN, Item Number: 650801715; 8) MTS,135
Fluid Delivery Sets were incorrectly assembled with a white macro drip chamber instead of the required grey micro drip chamber. The macro drip chamber delivers three times more fluid per drop than the micro drip chamber.
- 2025-01-22FDA-DeviceMEDLINE INDUSTRIES, LP - NorthfieldClass IMedline Fluid Delivery Set with Drip Chamber: 1) FDS,135,CHMN,W/F,MLL,RC(2),PG, Item Number 99000069; 2) FDS,135,NV,MICRO-CHAMBER,W/FILTER,BLUE, Item Number 949000222; 3) FDS,135,NV,MICRO-CHAMBER,W/FILTER,GREEN, Item Number 949000224; 4) FDS,135,NV,MICRO-CHAMBER,W/FILTER,RED, Item Number 949000221; 5) FDS,135,NV,MICRO-CHAMBER,W/FILTER,YELLOW, Item Number 949000223
Fluid Delivery Sets were incorrectly assembled with a white macro drip chamber instead of the required grey micro drip chamber. The macro drip chamber delivers three times more fluid per drop than the micro drip chamber.
- 2025-01-22FDA-DeviceTrokamed GmbHClass ISheath, 18 Fr., 160 mm (REF: WA2PS18L), gastroenterology-urology endoscopic access overtube.
If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
- 2025-01-22FDA-DeviceTrokamed GmbHClass ISheath, 18 Fr., 130 mm (REF: WA2PS18S), gastroenterology-urology endoscopic access overtube.
If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
- 2025-01-22FDA-DeviceTrokamed GmbHClass ISheath, 20 Fr., 160 mm (REF: WA2PS20L), gastroenterology-urology endoscopic access overtube.
If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
- 2025-01-22FDA-DeviceTrokamed GmbHClass ISheath, 20 Fr., 130 mm (REF: WA2PS20S), gastroenterology-urology endoscopic access overtube.
If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
- 2025-01-15FDA-Device3B Medical, Inc.Class IIBrand Name: 3B Medical, Inc. Product Name: Ultrasoft Oxygen Cannula, 12 Foot Model / Catalog Number: O2U2012 Lot Number: 20170403 Product Description: Nasal Cannulas for use with Oxygen Concentrators
The devices were inadvertently shipped after their expiration date.
- 2025-01-15FDA-DeviceNipro Renal Soultions USA, CorporationClass IICitric Complete - Dry Citric Acid Concentrate Model Number: DCA+225-25
The outer case is mislabeled as 3.0 K, 2.0 Ca instead of 2.0 K, 3.0 Ca.
- 2025-01-15FDA-DeviceApplied Medical Technology IncClass IIAMT Mini Enteral Extension Set, 12" Right Angle Feeding Set with Y-Port. Model/Catalog Number: E6-1222
The extension sets subject to this recall have ENFit connections, although they should have non- ENFit connections. ENFit connectors will only fit with other ENFit-compatible devices, and will not fit with non-ENFit connectors.
- 2025-01-15FDA-DeviceGE Medical Systems, LLCClass IITec 850 SEV Anesthesia Vaporizer, Reference Number 1177-9850-SEV
Due to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- 2025-01-15FDA-DeviceGE Medical Systems, LLCClass IITec 850 ISO Anesthesia Vaporizer, Reference Number 1177-9850-ISO
Due to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- 2025-01-15FDA-DeviceGE Medical Systems, LLCClass IITec 820 SEV Anesthesia Vaporizer, Reference Number 1177-9820-SEV
Due to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- 2025-01-15FDA-DeviceGE Medical Systems, LLCClass IITec 820 ISO Anesthesia Vaporizer, Reference Number 1177-9820-ISO
Due to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.
- 2025-01-15FDA-DeviceGE Medical Systems, LLCClass IITec 6 Plus Anesthesia Vaporizer, Reference Numbers 1107-9601-000, 1107-9602-000, 1107-9603-000, 1107-9604-000, 1107-9610-000, 1107-9612-000, 1107-9616-000, 1107-9617-000, 2066835-001, 2069767-001, 2078800-001, 2091008-001, 2091009-001, M1098876, M1145610, M1220023, M1220854, M1221495, and M1233992
Due to a manufacturing issue, certain Tec 6 Plus and Tec 800 series vaporizers can deliver less anesthetic agent than the vaporizer dial setting.