- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Bracket, REF 674-057, Reusable non-sterile bracket for use with SonoSite L25 series tranducers, Rx.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Starter Kit, REF 674-039, Reusable non-sterile bracket with sterile needle guides (1cm, 1.5cm, 2cm depths) with (10.2 x 147cm) CIV-Flex cover for use with SonoSite L25 series transducers, 22 GAUGE, Rx.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Starter Kit, REF 674-038, Reusable non-sterile bracket with sterile needle guide (1cm, 1.5cm, 2cm depths) with (10.2 x 147cm) CIV-Flex cover for use with SonoSite L25 series transducers, 21 GAUGE, Rx. The firm name on the label is CIVCO, Kalona, IA..
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Starter Kit, REF 674-037, Reusable non-sterile bracket with sterile needle guides (1.5cm, 2.5cm, 3.5cm, 4.5 depths) with (10.2 x 147cm) CIV-Flex cover for use with SonoSite L25 series transducers, 18 GAUGE, Rx.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Starter Kit, REF numbers P12924-01 and P12924-02, Reusable non-sterile bracket with sterile (1cm, 1.5cm, 2cm depths) needle guides (5), (10.2 x 147cm) CIV-Flex covers (5) for use with SonoSite L25 series transducers, 22 GAUGE, Rx.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Starter Kit, REF numbers P12922-01 and P12922-02, Reusable non-sterile bracket with sterile (1cm, 1.5cm, 2cm depths) needle guides (5), (10.2 x 147cm) CIV-Flex covers (5) for use with SonoSite L25 series transducers, 21 GAUGE, Rx.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Starter Kit, REF numbers P12920-01 and P12920-02, Reusable non-sterile bracket with sterile (1.5cm, 2.5cm, 3.5cm, 4.5cm depths) needle guides (5), (10.2 x 147cm) CIV-Flex covers ((5) for use with SonoSite L25 series transducers, 18 GAUGE, Rx.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IISonoSite FUJIFILM Needle Guide Bracket, REF number P06013-08, Reusable non-sterile bracket for use with SonoSite L25 series transducers. Mfg for:
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IISonoSite Needle Guide Bracket, REF numbers P06013-06 and P06013-07, Reusable non-sterile bracket for use with SonoSite L25 series transducers.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Biopsy Bracket, REF P03122-07, Reusable non-sterile single-angle bracket for use with SonoSite L25 series transducers.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Bracket, REF P03122-06, Reusable non-sterile bracket for use with SonoSite L25/L25e transducers, Mfg by: CIVCO, Kalona, IA.
The needle guide bracket may puncture the sterile cover applied over the transducer and bracket during assembly.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IISonoSite L25 Bracket Kit containing 1 Reusable non-sterile bracket, REF numbers P03122-01, P03122-02, P03122-03, P03122-04, and P03122-05, Mfg for: SonoSite, Inc., Bothell, WA.
The needle guide bracket may puncture the sterile cover applied over the transducer and bracket during assembly.
- 2018-12-19FDA-DeviceCIVCO Medical Instruments Co., Inc.Class IICIVCO Needle Guide Bracket, REF numbers M001457100, P06013-10, and P03122-08, reusable non-sterile single-angle bracket for use with SonoSite L25 series tranducers, RX. The firm name on the label is CIVCO, Kalona, IA.
The needle guide bracket may puncture the sterile cover applied over the transducer and bracket during assembly.
- 2018-12-12FDA-DeviceHelena Laboratories, Inc.Class IICascade Abrazo c-ACT-LR Test Card IVD FOR IN VITRO DIAGNOSTIC USE Store at 2 to 8 C HELENA LABORATORIES 003366 12/13(2) FOR EXPORT ONLY
Due to some cards in this lot reported to have experienced variations in results, (verified by wave form), resulting in some cards with shorter or longer times than expected.
- 2018-12-12FDA-DeviceAtrium Medical CorporationClass IIAtrium 28Fr PVC Thoracic Catheter RIGHT ANGLE, Part No. 8128
This recall has been initiated in response to a seal defect found in certain sterile barrier pouches containing the device. Affected pouches are un-sealed at the bottom. If the pouch defect is not detected it could represent a serious hazard to the patient. A sterility breach could potentially lead to product contamination. The potentially affected device is used in contact with critical anatomical structures and deep into the body. If contaminated, the consequences for the patient could be severe. The severity of the possible clinical complications depends on the degree of contamination of the device, the microorganisms involved and the patient s risk factors. To date, Getinge/Atrium has not received any reports of patient injury related to this issue.
- 2018-12-12FDA-DeviceTosoh Bioscience IncClass IIAIA-360 Analyzer, product code 019945/019945R The Tosoh AIA-360 Automated Immunoassay Analyzer is for use in vitro diagnostic to provide testing for a broad menu of assays in a unique patented dry reagent format.
The firm has implemented new product labeling changes for the Tosoh AIA-360 Analyzer. These labeling changes affect the Tosoh Quick Reference Guide, Training Manual and Training DVD previously provided by Tosoh Bioscience. These changes are being made to align the Tosoh Quick Reference Guide and associated training materials to the Operators Manual and provide clarification to the requirement that the maintenance of the B/F probe is to be performed by Tosoh a field service representative, the requirement for use of 70% Ethanol during daily shutdown procedures and the requirement for use of CAP Class 1 reagent grade water for dilution of the concentrated wash and diluent solutions and reconstitution of lyophilized reagents. Failure to follow these requirements may negatively affect system performance, lead to corrosion of instrument components over time, or result in bacterial contamination, respectively.
- 2018-12-12FDA-DeviceSiemens Medical Solutions USA, IncClass IIArtis Zee and Zeego, model no. 10272462 AXIOM Artis zee/Zeego is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients.
This recall has been initiated due to a possible leakage of a hose in the cooling unit of the X-ray tube. The Artis zee system may lose coolant due to a possible leakage in a hose of the cooling unit in the X-ray tube. This will cause the X-ray tube not to be sufficiently cooled down. As a result, the system will display a message Tube hot, have a break . The X-ray will be blocked several minutes later and to prevent any damage to the machine the following message will be displayed NO XRAY, TUBE TOO HOT . This issue is very sporadic and may occur during an ongoing clinical procedure. Use of this product may have a potential impact on planned procedures as they may be delayed as well as in emergent cases, as clinical treatment may need to be terminated and transferred to a functioning system.
- 2018-12-12FDA-DeviceStephanixClass IISTEPHANIX D2RS Digital Dynamic Remote Systemhttp://cts.fda.gov/division-tracking/images/trash.png Product The D2RS Digital Dynamic Remote System is indicated for use in generating fluoroscopic images of human anatomy for vascular angiography, diagnostic and interventional procedures. It is also indicated for generating fluoroscopic images of human anatomy for cardiology, diagnostic, and interventional procedures. It is intended to replace fluoroscopic images obtained through image intensifier
The firm has detected a potential risk using the command. After releasing the command, the movement of the table may continue instead of stopping.
- 2018-12-12FDA-DevicePfizer Inc.Class IIThermacare HEATWRAPS JOINT PAIN THERAPY, 8 HEATWRAPS; MUSCLE PAIN THERAPY, 3 HEATWRAPS a) UPC 0573301311 b) UPC 0573301311 Product Usage: Provides heat therapy for temporary relief of minor muscular and joint aches and pains associated with overexertion, sprains, and arthritis.
The firm received complaints of the wrap coming apart and leaking granular material
- 2018-12-12FDA-DevicePfizer Inc.Class IIThermacare HeatWraps Menstrual a) UPC 0573302002 b) UPC 0573302044 Product Usage: Provides heat therapy for temporary relief of minor menstrual cramp pain and associated back aches.
The firm received complaints of the wrap coming apart and leaking granular material
- 2018-12-12FDA-DevicePfizer Inc.Class IIThermacare Muscle Pain Therapy HeatWraps: a) UPC 0573301314 b) UPC 0573301303 Product Usage: Provides heat therapy for temporary relief of minor muscular and joint aches and pains associated with overexertion, sprains, and arthritis.
The firm received complaints of the wrap coming apart and leaking granular material
- 2018-12-12FDA-DeviceZimmer Biomet, Inc.Class IIBiomet 20mm Compress Device Short Anchor Plug With Drill Set / With Pin Inserter Ion Implant Item number: 178562 Product Usage: 1. Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. 2. Tumor resections. 3. Revision of previously failed total joint arthroplasty. 4. Trauma. The Compress¿ Segmental Femoral Replacement System (Short Spindle and Anchor Plug) components are intended for uncemented use only.
Potential metal burrs in the holes of the device preventing the appropriate drill and transverse pins from being inserted
- 2018-12-12FDA-DeviceCapintec IncClass IICaptus 700 Thyroid Uptake System, Model # 5430-3137 and 5430-3138
There is a potential for the spring arm failure as a result of a broken tension rod (a component inside the arm). A break in the tension rod can casue the collimator to fall downward to its lowest point of travel, approximately 25 inches from the ground.
- 2018-12-12FDA-DeviceCapintec IncClass IICaptus 3000 Thyroid Uptake System, Model # 5430-0076 and 5430-0077
There is a potential for the spring arm failure as a result of a broken tension rod (a component inside the arm). A break in the tension rod can casue the collimator to fall downward to its lowest point of travel, approximately 25 inches from the ground.
- 2018-12-12FDA-DeviceInvacare CorporationClass IIInvacare 9805 and 9805P Hydraulic Patient Lifts, Model Nos. 9805 and 9805P The intended use of a Non-AC-Powered patient lift is to lift and transfer a patient from one surface to another, as from a bed to a wheelchair. The device includes straps and a sling to support the patient.
Invacare has identified via customer complaints, the potential for the mounting bolt connecting the caster to the base frame of the patient lifts to become loose. Loose hardware can cause wear to the hardware and housings. If left unresolved, the caster may separate from the base of the lift causing the Lift to tilt and a patient fall. Failure does not occur right away but happens over time if the lift is not properly maintained. Patient falls are inherently dangerous and may result in a range of injuries that are dependent on physical condition of the patient and the nature of the fall. When injuries occur, they are typically non-serious injuries such as bruising, lacerations, or abrasions. In rare cases, more serious injuries such as bone fracture, head trauma, or death can occur. For caregivers using the lift, attempts to manually stabilize a lift if it becomes unstable could result in sprains, serious back injuries, or bone fractures.
- 2018-12-12FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIBrilliance 6 Slice (Air), Model 728256 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes. These devices may include signal analysts and display equipment, patient and equipment supports, components, and accessories
There is a potential for separation of fiberglass resin which may cause the gantry front cover and the metal support on the cover to fail/fall
- 2018-12-12FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIBrilliance 10 Slice (Air), Model 728251 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes. These devices may include signal analysts and display equipment, patient and equipment supports, components, and accessories
There is a potential for separation of fiberglass resin which may cause the gantry front cover and the metal support on the cover to fail/fall
- 2018-12-12FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIBrilliance 16 Slice (Air), Model 728246 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes. These devices may include signal analysts and display equipment, patient and equipment supports, components, and accessories
There is a potential for separation of fiberglass resin which may cause the gantry front cover and the metal support on the cover to fail/fall
- 2018-12-12FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIBrilliance 16 Slice (Power), Model 728240 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes. These devices may include signal analysts and display equipment, patient and equipment supports, components, and accessories
There is a potential for separation of fiberglass resin which may cause the gantry front cover and the metal support on the cover to fail/fall
- 2018-12-12FDA-DevicePhilips Medical Systems (Cleveland) IncClass IIBrilliance 40, Model 728235 Product Usage: Computed Tomography X-ray systems intended to produce cross-sectional Images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes. These devices may include signal analysts and display equipment, patient and equipment supports, components, and accessories
There is a potential for separation of fiberglass resin which may cause the gantry front cover and the metal support on the cover to fail/fall