Medical device recalls
39226 federal recalls on file. Federal recalls for medical devices — surgical equipment, monitors, diagnostic tools, implants, home health devices. Sourced from the FDA.
- 2018-09-12FDA-DeviceSteris CorporationClass IIAMSCO V-PRO 1, V-PRO 1 Plus, and V-PRO maX Low Temperature Sterilization Systems The V-PRO 1, V-PRO 1 Plus, and V-PRO maX Low Temperature Sterilization Systems, using VAPROX HC Sterilant, are intended for use in the terminal Sterilization of properly prepared (cleaned, rinsed and dried) metal and nonmetal medical devices in Healthcare Facilities.
There is the potential for a scenario where a punctured cup of sterilant expires while the system is powered down, upon power-up the unit will not detect the expired cup of sterilant; allowing for subsequent cycles to be run.
- 2018-09-12FDA-DevicePerkinElmer Life and Analytical Sciences, Wallac, OYClass IIIAutoDELFIA Neonatal immunoreactive trypsin(ogen) (IRT) kit, intended for the quantitative determination of human immunoreactive trypsin(ogen) (IRT) in blood specimens. (UDI: (01)06438147298716(17)190430(10)656479); Product Number: B005-212
The Quality Control Certificate for certain AutoDELFIA Neonatal IRT Kits is missing information required to assess the acceptability of measured control values which may result in a delay in reporting IRT results.
- 2018-09-05FDA-DeviceCovidien LLCClass IILi-ion battery packs used in BIS Vista and BIS View Monitoring Systems. Product Number/CFN: 186-0208 UDI-Device Identifier (GTIN/UPN): 10884521130319
Revised replacement instructions for the Li-ion battery packs used in BIS Vista and BIS View Monitoring Systems
- 2018-09-05FDA-DeviceBaxter Healthcare CorporationClass IIFLOSEAL Special Applicator Tips in cartons labeled in part, "Floseal SPECIAL APPLICATOR TIPS***6 x Malleable Tip Trimmable Tip***Baxter***." The pouches inside the cartons are labeled in part, "Floseal SPECIAL APPLICATOR TIPS***Baxter***"."
Baxter r recalled this device due to the use of an incorrect plastic formulation in the manufacture of the blue luer component of the FLOSEAL malleable tips.
- 2018-09-05FDA-DeviceGE Medical Systems China Co., Ltd.Class IIGE 9100c NXT anesthesia systems
On systems equipped with the Auxiliary Common Gas Outlet (ACGO), there is a potential for the auxiliary gas switch to unexpectedly switch from the ACGO position back to the circle position. On systems equipped with the Aux O2 + Air function the switch could unexpectedly switch from the Aux O2 + Air position back to the circle position. These situations could lead to hypoxia.
- 2018-09-05FDA-DeviceGE Medical Systems China Co., Ltd.Class IIGE Carestation 30 anesthesia systems
On systems equipped with the Auxiliary Common Gas Outlet (ACGO), there is a potential for the auxiliary gas switch to unexpectedly switch from the ACGO position back to the circle position. On systems equipped with the Aux O2 + Air function the switch could unexpectedly switch from the Aux O2 + Air position back to the circle position. These situations could lead to hypoxia.
- 2018-09-05FDA-DeviceGE Medical Systems China Co., Ltd.Class IIGE Carestation 620/650/650c, A1 and A2 (non-US distribution) anesthesia systems
On systems equipped with the Auxiliary Common Gas Outlet (ACGO), there is a potential for the auxiliary gas switch to unexpectedly switch from the ACGO position back to the circle position. On systems equipped with the Aux O2 + Air function the switch could unexpectedly switch from the Aux O2 + Air position back to the circle position. These situations could lead to hypoxia.
- 2018-09-05FDA-DeviceSysmex America, Inc.Class IISysmex XN-Series Fluorocell PLT, Catalog #CD994563. Distributed in the U.S.A. by Sysmex America, Inc., Lincolnshire, IL. Fluorocell PLT is used to stain platelets in a diluted blood sample for the counting of platelets with the Sysmex XN-Series automated hematology analyzers.
The fluorescent platelet counts (PLT-F) and immature platelet fraction (IPF) values can be falsely low when using affected lots of Fluorocell PLT.
- 2018-09-05FDA-DeviceLuminex CorporationClass IIVerigene Enteric Pathogens Nucleic Acid Test (EP) for detecting and identification of pathogenic enteric bacteria, viruses, and genetic virulence markers from liquid or soft stool preserved in Cary-Blair medium, collected from individuals with signs and symptoms of gastrointestinal infection.
Elevated false positive results Yersinia enterocolitica (Yersinia) from customers using the EP Nucleic Acid Test Cartridges component (20-006-023) from the Verigene EP Nucleic Acid Test Kit (20-005-023).
- 2018-09-05FDA-DeviceHaemonetics CorporationClass IIHaemonetics¿ OrthoPAT¿ System-OPAT QuickConnect Reservoirs. Product Code: OPT-R-1000 The OrthoPAT orthopedic perioperative autotransfusion system indicated for use to salvage RBCs from blood lost intraoperatively and postoperatively during surgical procedures
OrthoPAT¿ reservoirs are missing the cannula inside the reservoirs. The absence of this cannula prevents the emptying of blood from the reservoirs. The inability to empty the reservoir means that the collected blood cannot be processed.
- 2018-09-05FDA-DeviceHaemonetics CorporationClass IIHaemonetics OrthoPAT System-Integrated Set. Product Code: 1150H-00 OrthoPAT orthopedic perioperative autotransfusion system indicated for use to salvage RBCs from blood lost intraoperatively and postoperatively during surgical procedures
OrthoPAT¿ reservoirs are missing the cannula inside the reservoirs. The absence of this cannula prevents the emptying of blood from the reservoirs. The inability to empty the reservoir means that the collected blood cannot be processed.
- 2018-09-05FDA-DeviceDePuy Orthopaedics, Inc.Class IIP.F.C. SIGMA Revision Knee System Distal Augment, Model Number 960830
This unit may be missing the screw/collet Assembly
- 2018-09-05FDA-DeviceMedline Industries IncClass IIMedline 0.9 % Sodium Chloride Injection, USP 5 mL in 10 mL Syringe ZR Intended for flushing IV catheters and IV tubing only.
Packaged with an incorrect overwrap.
- 2018-09-05FDA-DeviceCivco Medical Instruments Co. Inc.Class IICIVCO Needle Guide, REF 676-150, QTY 24, STERILE EO
The assembly of the needle guides were found to be either missing adhesive or did not have adequate adhesive to hold the assembled cannula in place on the needle guide.
- 2018-09-05FDA-DeviceCivco Medical Instruments Co. Inc.Class IICIVCO Needle Guide, REF 676-144, QTY 24, STERILE EO
The assembly of the needle guides were found to be either missing adhesive or did not have adequate adhesive to hold the assembled cannula in place on the needle guide.
- 2018-09-05FDA-DeviceCeterix Orthopedics, Inc.Class IICeterix Disposable Knot Pusher / Suture Cutter; NovoCut Suture Manager. Model# CTX-C001. orthopedic arthroscopic accessory.
Possible nonconforming blades may result in a higher than specified cut force required to cut the suture.
- 2018-09-05FDA-DeviceRoche Diagnostics CorporationClass IIRoche cobas p 612 pre-analytical system (63x) Model: 07563116001 The cobas p 612 pre-analytical system is a computer controlled fully automatic system for sorting of open and closed barcoded and centrifuged and non-centrifuged sample tubes. The cobas p 612 is intended for use with analyzers that perform tests in the area of clinical chemistry, immuno chemistry, coagulation, hematology, urinalysis, nucleic acid testing.
Sample material may potentially come in contact with the pipetting nozzle during operation of cobas p 612 pre-analytical system (63x) (LCP1) with non-filter tips. The possible presence of biological material on the nozzle may cause contamination resulting in potential false positive results, depending on the sensitivity of the analytical technology.
- 2018-09-05FDA-DeviceBard Medical DivisionClass IIBard Midstream Urine Collector with Rigid Funnel and Iodophor Prep Pads. Product Packaging: Three (3) PVP-I prep pads are packed into each urine collection kit carton along with a pre-connected drainage funnel, specimen container, funnel lid, specimen lid and a room label.
Medline notified BMD that the Aplicare Povidone Iodine (PVP-I) Prep Pads were not meeting the iodine assay level requirements to support 36 month expiration dating.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDUO FLOW DOUBLE LUMEN CATHETER, XTP114CT, XTP114MT, ; RAULERSON DUO FLOW IJ DOUBLE LUMEN CATHETER/CATHETER SET, XTP114IJC, XTP114IJS, XTP114IJSE, XTP114MT-C, XTP116IJC, XTP116IJS, XTP116IJSE RAULERSON PRE-CURVED DUO-FLOW IJ DOUBLE LUMEN CATHETER W/SOFT TIP SET, W/MINI SCALPEL, SYRINGE, AND NEEDLE, XTP118IJS-ID; DOUBLE LUMEN CATHETER WITH CURVED EXTENSIONS (CATHETER ONLY), XTP114IJC=, XTP116IJC=, DOUBLE LUMEN IJ CATHETER SET, XTP114IJS=, XTP115IJS=, XTP116IJS=, XTP116IJS=JO, DOUBLE LUMEN
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDUO FLOW CUSTOM TRAYS; TRAY #414 TRAY #415 TRAY #67
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IISOFT-LINE DUO-FLOW DOUBLE LUMEN CATHETER/CATHETER SET; T94C T94M T96M T98M
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IISOFT-LINE DUO-FLOW DOUBLE LUMEN CATHETER TRAY; T3500 T4000 T4400 T4424
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDuo-Flow Double Lumen Catheter Only/Catheter Set; T114C T114M T116C T116M T116ME T118C T118M T118ME T119M
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDuo-Flow XTP Straight Full Set, RMS02105 RMS02108
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDuo-Flow Catheter Full Tray; MCDLT3500 MCDLT4000 MCDLT4400 MCDLT4424# Hemodialysis catheter insertion kits
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDuo-Flow IJ Full Tray; MCDLT114IJ MCDLT116IJ MCDLT118IJ
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDuo-Flow Double Lumen Soft Tip CRRT/ABP Catheter Set; DL11/24 . Hemodialysis catheter insertion kits
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDouble Lumen CRRT/ABP Catheter Set; Hemodialysis catheter insertion kits, DL 11/15 DL 11/20 DL 9/15
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceMedical Components, Inc dba MedCompClass IIDuo-Flow XTP Straight Full Set; Hemodialysis catheter insertion kits, AAC02106 AAC02107 AAC02108
The suture wings have the potential to crack or break. Potential patient injury includes catheter dislocation, bleeding, and air emboli. The firm has received six complaints (29 broken suture wings) to date for malfunction, without serious injury or death.
- 2018-09-05FDA-DeviceCSL Behring GmbHClass IIN Latex CDT Kit
Siemens Healthcare Diagnostics has observed a negative bias for the carbohydrate-deficient transferrin (CDT) measurement when using the affected N Latex CDT lots in comparison to the HPLC method. CDT results in absolute concentrations may be influenced by patients transferrin levels and, therefore, results are reported as ratio of CDT to total transferrin, called %CDT. As the transferrin determination with N Antiserum to Human Transferrin is not affected, the observed effect leads to calculated %CDT values that show a negative bias of approximately 15% compared to the HPLC method. This could result in a shift of weak positive patient samples into the reference range of 1.19 2.47 %CDT which was derived from a study population of healthy adults. There are no control or calibrator materials that would catch this bias.